Smallest personal gas monitor 1-5 sensors with a built-in pump

RKI - GX-2012
Ideal for line purge testing

$1,458.50 CAD$1,580.00 CAD

  • 12 months limited warranty
  • 4 sensors-LEL/O2/H2S/CO
  • 5 sensors- LEL/%volume/Oxy/CO/H2S
  • 3 Operating modes: Normal, leak check, & bar hole
  • Free shipping across Canada
CLICK HERE FOR A CALIBRATION CERTIFICATE $110.00 CAD

What model suits me best?
1 800 463-4363

 

With the GX-2012, you have multiple tools in one instrument

Ideal for residential investigations, line purge testing. Built around high-quality micro-sensor technology, the GX-2012 is RKI’s smallest personal 1-5 sensor gas monitor with a built-in sample pump. Weighing only 12.3 ounces, the GX-2012 can monitor the standard confined space gases (LEL combustibles, Oxygen content, Carbon Monoxide, and Hydrogen Sulfide)

Having 3 operating modes, the GX-2012 can be used for confined space, safety monitoring in its Normal Operating mode; leak investigation in Leak Check mode; and underground leak checking in Bar Hole mode. When equipped with an optional TC sensor, the GX-2012 can measure 100% volume methane and dynamically auto-range from % LEL to % volume. This is ideal for line purge testing.

GX-2012 Gas monitor operation

The GX-2012’s large LCD display shows all gas readings, battery level, current time, and will automatically backlight in alarm conditions. Standard alarm types include vibration, visual, and audible alarms, which can be set to latching or non-latching. Controlled by a microprocessor, the GX-2012 continuously checks itself for sensor connections, low battery, circuit trouble, low flow, and calibration errors. The GX-2012 can interchangeably operate on either a Li-ion battery pack or an alkaline battery pack. The batteries are simple to replace requiring no tools to access the removable battery compartment or pack.

Calibration and bump test intervals and reminders are user adjustable and can be set to either go into alarm or to lock the user out of normal measurement mode once a calibration period has expired. Calibrations can be performed automatically or individually in a single calibration mode. The GX-2012 is also compatible with the economical SDM-2012 single channel calibration station.

personal gas monitor at a great price:

  1. Monitors ppm LEL, and % volume methane, O2, CO and H2S
  2. 0 to 100% volume methane option
  3. Auto-ranging display of % LEL and % volume 3 Operating modes: Normal, leak check, & bar hole
  4. Leak check mode:
  5. PPM leak detector detects down to 100 ppm CH4
  6. Adjustable display ranges: 500/1000/2000/5000 ppm
  7. Visual/audible pulses change with gas concentration
  8. CO display in leak check mode, ideal for residential investigations
  9. Borehole test mode for underground leak checks
  10. Status indicators: Pump active, microprocessor status, and battery level
  11. Internal sample drawing pump with up to 50-foot range
  12. Vibration, visual, and audible alarms
  13. Automatic backlight during alarms
  14. Bump test and calibration reminder with lockout option
  15. Lithium-ion or alkaline battery packs (interchangeable)
  16. Alarm latching or non-latching
  17. High impact, dust, and water-resistant design
  18. Up to 600 hours of data logging with alarm trends
  19. Snap-logging – on-demand data recording
  20. TWA and STEL readings with lunch-break mode
  21. Intrinsically safe, ATEX/IECEx/CE and (CSA version also available)
  22.  2-year warranty

Specifications

Gas Detected Combustible Gases
(Methane as standard)
% Volume Methane Oxygen (O2) Hydrogen Sulfide (H2S) Carbon Monoxide (CO)
Detection Principle Catalytic combustion Thermal conductivity Galvanic cell Electrochemical cell
Detection Range 0 ~ 100% LEL
0 ~ 500 / 1,000 /
2,000 / 5,000 ppm
0 ~ 100% Vol. 0 ~ 40% Vol. 0 ~ 100 ppm
(Optional 0-500 ppm)
0 ~ 500 ppm
Accuracy Statement (whichever is greater) ± 5% of reading or
± 2% LEL
(LEL mode only)
± 5% of reading or
± 2% of full scale
± 0.5% O2 ± 5% of reading or ± 2 ppm H2S ± 5% of reading or ± 5 ppm CO
Sampling Method Internal sample pump, flow rate nominal 0.5 LPM, includes a hydrophobic filter
Display Digital LCD with 7 segments, auto backlight during alarm
Preset Alarms
(User Adjustable)
1st alarm 10% LEL 2nd alarm 50% LEL Over alarm 100% LEL No alarms for
% Vol. CH4
Low alarm 19.5%
High alarm 23.5%
Over alarm 40.0%
1st 5 ppm
2nd 30 ppm
TWA 10 ppm
STEL 15 ppm
Over 100 ppm
1st 25 ppm
2nd 50 ppm
TWA 25 ppm
STEL 200 ppm
Over 500 ppm
Alarms Types Gas alarms:         1st and 2nd, STEL, TWA (user adjustable) and OVER
Trouble alarms:    Sensor connection, low battery, low flow, circuit trouble and calibration error
Alarm Methods Gas alarms:         Flashing lights, two-tone buzzer, and vibration
Trouble alarms:    Flashing lights, trouble displayed, intermittent buzzer, and vibration
Operating Temp. & Humidity -20°C to +50°C (-4°F to 122°F)
0 to 95% RH, non-condensing
Response Time Within 30 seconds (T90)
Continuous Operation Alkaline battery:  15 hours                Li-Ion battery:  10 hours 70°F (21°C)
Power Source Li-Ion battery pack, or 3 “AA” Alkaline battery pack; interchangeable
Safety Rating ATEX, TIIS, IECEx, CE, CSA classified (as standard),as intrinsically safe. Class I, Division 1, Groups A, B, C, D (optional version available)
Dimension & Weight Approx. 143 (H) x 71 (W) x 43 (D) mm (5.6” H x 2.8” W x 1.6” D),approx. 350 g (12.3 ounces)
Case Material High dust & water resistant design. RFI shielded high impact plastic with protective rubber over-molding
Controls Five buttons: POWER / ENTER, DISPLAY, AIR, RESET, SHIFT
Standard Accessories • Belt clip                            • Rubber nozzle, 3.5”                        • Datalogging software
• 10” Probe                         • Manual                                           • Quick reference card
• 10’ Hose                           • Training CD
Optional Accessories • SDM-2012 calibration stations                                   • Calibration kit
• Li-Ion battery pack                                                     • AC or DC Charger
• Sample draw hoses (10’ standard,                            • Carrying case up to 100’ max. available)

Also available for rent!

QUICK TIP:
Responding to Alarms
This section describes response to gas, over range, battery, and sensor failure alarms.
Responding to Gas Alarms
1. Determine which gas alarm has been activated.
2. Follow your established procedure for an increasing gas condition or a decreasing
oxygen condition.
3. If necessary, reset the alarm using the RESET SILENCE button once the alarm
condition has been cleared.

Download Data Sheet
Download Instruction Manual

With the GX-2012, you have multiple tools in one instrument

Ideal for residential investigations, line purge testing. Built around high-quality micro-sensor technology, the GX-2012 is RKI’s smallest personal 1-5 sensor gas monitor with a built-in sample pump. Weighing only 12.3 ounces, the GX-2012 can monitor the standard confined space gases (LEL combustibles, Oxygen content, Carbon Monoxide, and Hydrogen Sulfide)

Having 3 operating modes, the GX-2012 can be used for confined space, safety monitoring in its Normal Operating mode; leak investigation in Leak Check mode; and underground leak checking in Bar Hole mode. When equipped with an optional TC sensor, the GX-2012 can measure 100% volume methane and dynamically auto-range from % LEL to % volume. This is ideal for line purge testing.

GX-2012 Gas monitor operation

The GX-2012’s large LCD display shows all gas readings, battery level, current time, and will automatically backlight in alarm conditions. Standard alarm types include vibration, visual, and audible alarms, which can be set to latching or non-latching. Controlled by a microprocessor, the GX-2012 continuously checks itself for sensor connections, low battery, circuit trouble, low flow, and calibration errors. The GX-2012 can interchangeably operate on either a Li-ion battery pack or an alkaline battery pack. The batteries are simple to replace requiring no tools to access the removable battery compartment or pack.

Calibration and bump test intervals and reminders are user adjustable and can be set to either go into alarm or to lock the user out of normal measurement mode once a calibration period has expired. Calibrations can be performed automatically or individually in a single calibration mode. The GX-2012 is also compatible with the economical SDM-2012 single channel calibration station.

personal gas monitor at a great price:

  1. Monitors ppm LEL, and % volume methane, O2, CO and H2S
  2. 0 to 100% volume methane option
  3. Auto-ranging display of % LEL and % volume 3 Operating modes: Normal, leak check, & bar hole
  4. Leak check mode:
  5. PPM leak detector detects down to 100 ppm CH4
  6. Adjustable display ranges: 500/1000/2000/5000 ppm
  7. Visual/audible pulses change with gas concentration
  8. CO display in leak check mode, ideal for residential investigations
  9. Borehole test mode for underground leak checks
  10. Status indicators: Pump active, microprocessor status, and battery level
  11. Internal sample drawing pump with up to 50-foot range
  12. Vibration, visual, and audible alarms
  13. Automatic backlight during alarms
  14. Bump test and calibration reminder with lockout option
  15. Lithium-ion or alkaline battery packs (interchangeable)
  16. Alarm latching or non-latching
  17. High impact, dust, and water-resistant design
  18. Up to 600 hours of data logging with alarm trends
  19. Snap-logging – on-demand data recording
  20. TWA and STEL readings with lunch-break mode
  21. Intrinsically safe, ATEX/IECEx/CE and (CSA version also available)
  22.  2-year warranty

Specifications

Gas Detected Combustible Gases
(Methane as standard)
% Volume Methane Oxygen (O2) Hydrogen Sulfide (H2S) Carbon Monoxide (CO)
Detection Principle Catalytic combustion Thermal conductivity Galvanic cell Electrochemical cell
Detection Range 0 ~ 100% LEL
0 ~ 500 / 1,000 /
2,000 / 5,000 ppm
0 ~ 100% Vol. 0 ~ 40% Vol. 0 ~ 100 ppm
(Optional 0-500 ppm)
0 ~ 500 ppm
Accuracy Statement (whichever is greater) ± 5% of reading or
± 2% LEL
(LEL mode only)
± 5% of reading or
± 2% of full scale
± 0.5% O2 ± 5% of reading or ± 2 ppm H2S ± 5% of reading or ± 5 ppm CO
Sampling Method Internal sample pump, flow rate nominal 0.5 LPM, includes a hydrophobic filter
Display Digital LCD with 7 segments, auto backlight during alarm
Preset Alarms
(User Adjustable)
1st alarm 10% LEL 2nd alarm 50% LEL Over alarm 100% LEL No alarms for
% Vol. CH4
Low alarm 19.5%
High alarm 23.5%
Over alarm 40.0%
1st 5 ppm
2nd 30 ppm
TWA 10 ppm
STEL 15 ppm
Over 100 ppm
1st 25 ppm
2nd 50 ppm
TWA 25 ppm
STEL 200 ppm
Over 500 ppm
Alarms Types Gas alarms:         1st and 2nd, STEL, TWA (user adjustable) and OVER
Trouble alarms:    Sensor connection, low battery, low flow, circuit trouble and calibration error
Alarm Methods Gas alarms:         Flashing lights, two-tone buzzer, and vibration
Trouble alarms:    Flashing lights, trouble displayed, intermittent buzzer, and vibration
Operating Temp. & Humidity -20°C to +50°C (-4°F to 122°F)
0 to 95% RH, non-condensing
Response Time Within 30 seconds (T90)
Continuous Operation Alkaline battery:  15 hours                Li-Ion battery:  10 hours 70°F (21°C)
Power Source Li-Ion battery pack, or 3 “AA” Alkaline battery pack; interchangeable
Safety Rating ATEX, TIIS, IECEx, CE, CSA classified (as standard),as intrinsically safe. Class I, Division 1, Groups A, B, C, D (optional version available)
Dimension & Weight Approx. 143 (H) x 71 (W) x 43 (D) mm (5.6” H x 2.8” W x 1.6” D),approx. 350 g (12.3 ounces)
Case Material High dust & water resistant design. RFI shielded high impact plastic with protective rubber over-molding
Controls Five buttons: POWER / ENTER, DISPLAY, AIR, RESET, SHIFT
Standard Accessories • Belt clip                            • Rubber nozzle, 3.5”                        • Datalogging software
• 10” Probe                         • Manual                                           • Quick reference card
• 10’ Hose                           • Training CD
Optional Accessories • SDM-2012 calibration stations                                   • Calibration kit
• Li-Ion battery pack                                                     • AC or DC Charger
• Sample draw hoses (10’ standard,                            • Carrying case up to 100’ max. available)

Also available for rent!

QUICK TIP:
Responding to Alarms
This section describes response to gas, over range, battery, and sensor failure alarms.
Responding to Gas Alarms
1. Determine which gas alarm has been activated.
2. Follow your established procedure for an increasing gas condition or a decreasing
oxygen condition.
3. If necessary, reset the alarm using the RESET SILENCE button once the alarm
condition has been cleared.

Download Data Sheet
Download Instruction Manual