Air particle counter & gas detector

Geneq - GE9883M-00
Air particle counter at a great price

$2,130.00 CAD

  • 12 months limited warranty
  • GAS Formaldehyde (HCHO) & Carbon Dioxide (CO²) detectors
  • Air temperature and humidity, Dew point & Wet bulb temperature
  • 2.8″ TFT 320×240 pixels Color LCD display
CLICK HERE FOR A CALIBRATION CERTIFICATE $110.00 CAD

Support, maintenance, calibration
1 800 463-4363

 

The Air Particle Counter & Gas Detector provides fast, easy, and accurate readings for particle count

It can measure Suspended Particle Concentration, GAS Formaldehyde (HCHO) & Carbon Dioxide (CO²) detection, air temperature & relative humidity & most surface temperature measurements.

Multifuctional meter allows to determine the number of particles in the size of 0.3, 2.5, and 10 µm. In addition to measuring the particles, the fine dust can also measure the PM 2.5 and PM 10 mass concentrations.
The mass concentration of the fine dust determines the weight of the particles in one cubic meter.
Determines the formaldehyde content in ppm. During this HCHO measurement, the temperature, the ambient humidity, and the dew point are determined and displayed by it.  As a further important feature, it can all store data and it is, therefore, possible to evaluate all measured values ​​after a measurement.
An ideal instrument for environmental safety and energy-saving surveys.

Air particle counter at a great price

  • 2.8″ TFT 320×240 pixels Color LCD display
  • Images(JPEG) & Video(3GP)
  • Simultaneously measure and display 6 channels of particle sizes, measure particle size down to 0.3 µm
  • The determination of suspended particle concentration in the air of the weight method (PM2.5/PM10)
  • GAS (HCHO) detectors
  • TVOC, CO2
  • Air temperature and humidity, Dewpoint & Wet bulb temperature
  • Max, Min, DIF, AVG record, Date/time setup controls, alarm
  • MicroSD (MAX. use 8GB) memory card, USB interface
  • Auto Power Off
  • Selectable sample time, count data, programmable delay
  • Store 5000 records of the date, time, counts, relative humidity, temperature, sample volumes, alarms, and location label
  • Language selection English, Chinese, French, German, Spanish
Specifications
Particle Counter DT-9883M
Channel 0.3, 0.5, 1.0,2.5, 5.0, 10μm *
Flow Rate 0.1ft 3 (2.83L/min) controlled by internal pump *
Count Modes Totalize, Concentration, Audio *
Coincidence Loss 5%, 2,000,000 particles per ft³ *
Mass Concentration Channel PM2.5 :0~500ug/m³ ;PM10:0~500ug/m³ *
Air Temperature Measure
Air Temp Range 0 to 50ºC/32 to 122ºF;

Basic Accuracy: ±0.5ºC/1ºF

*
Humidity Range 0 to 100%RH;

Basic Accuracy: ±2.5%RH (20%~80%RH)

*
Dew Point Temp. Range -30~100ºC/ -22~199ºF *
Wet Bulb Temp. Range 0~80ºC/ 32~176ºF
GAS Detectors
HCHO (methanal) Range 0.01~5.00ppm; Basic Accuracy: ±5%F.S *
CO (carbon monoxide) Range 0~1000ppm; Basic Accuracy:±5%F.S
CO2 Range 0~9999ppm:Basic Accuracy: ±75PPM±5% of reading *
TVOC Range 0.00~10mg/m³;Accuracy: ±5%F.S *

 

The Air Particle Counter & Gas Detector provides fast, easy, and accurate readings for particle count

It can measure Suspended Particle Concentration, GAS Formaldehyde (HCHO) & Carbon Dioxide (CO²) detection, air temperature & relative humidity & most surface temperature measurements.

Multifuctional meter allows to determine the number of particles in the size of 0.3, 2.5, and 10 µm. In addition to measuring the particles, the fine dust can also measure the PM 2.5 and PM 10 mass concentrations.
The mass concentration of the fine dust determines the weight of the particles in one cubic meter.
Determines the formaldehyde content in ppm. During this HCHO measurement, the temperature, the ambient humidity, and the dew point are determined and displayed by it.  As a further important feature, it can all store data and it is, therefore, possible to evaluate all measured values ​​after a measurement.
An ideal instrument for environmental safety and energy-saving surveys.

Air particle counter at a great price

  • 2.8″ TFT 320×240 pixels Color LCD display
  • Images(JPEG) & Video(3GP)
  • Simultaneously measure and display 6 channels of particle sizes, measure particle size down to 0.3 µm
  • The determination of suspended particle concentration in the air of the weight method (PM2.5/PM10)
  • GAS (HCHO) detectors
  • TVOC, CO2
  • Air temperature and humidity, Dewpoint & Wet bulb temperature
  • Max, Min, DIF, AVG record, Date/time setup controls, alarm
  • MicroSD (MAX. use 8GB) memory card, USB interface
  • Auto Power Off
  • Selectable sample time, count data, programmable delay
  • Store 5000 records of the date, time, counts, relative humidity, temperature, sample volumes, alarms, and location label
  • Language selection English, Chinese, French, German, Spanish
Specifications
Particle Counter DT-9883M
Channel 0.3, 0.5, 1.0,2.5, 5.0, 10μm *
Flow Rate 0.1ft 3 (2.83L/min) controlled by internal pump *
Count Modes Totalize, Concentration, Audio *
Coincidence Loss 5%, 2,000,000 particles per ft³ *
Mass Concentration Channel PM2.5 :0~500ug/m³ ;PM10:0~500ug/m³ *
Air Temperature Measure
Air Temp Range 0 to 50ºC/32 to 122ºF;

Basic Accuracy: ±0.5ºC/1ºF

*
Humidity Range 0 to 100%RH;

Basic Accuracy: ±2.5%RH (20%~80%RH)

*
Dew Point Temp. Range -30~100ºC/ -22~199ºF *
Wet Bulb Temp. Range 0~80ºC/ 32~176ºF
GAS Detectors
HCHO (methanal) Range 0.01~5.00ppm; Basic Accuracy: ±5%F.S *
CO (carbon monoxide) Range 0~1000ppm; Basic Accuracy:±5%F.S
CO2 Range 0~9999ppm:Basic Accuracy: ±75PPM±5% of reading *
TVOC Range 0.00~10mg/m³;Accuracy: ±5%F.S *