Smoke Combustion analyzer with printer

Testo - 300
Ideal for the most important measurements involving heating systems.

$2,395.50 CAD

  • O2 sensor and CO sensor up to 4,000 ppm
  • testo Bluetooth® Connector (0554 3004)
  • Longer sensor service life thanks to automatic sensor protection

Support, maintenance, calibration
1 800 463-4363

 

The Smoke Combustion analyzer with printer enables easy measurement of flue gas, draft, pressure, ambient CO and differential temperature.

The Next-Gen testo 300 combustion analyzer is supplied with O2 and CO sensor (CO range up to 4,000 ppm),combustion probe, testo Bluetooth® Connector, instrument case, printer, and practical accessories.

Impressive measuring technology and quality

  • O2 sensor and CO sensor up to 4,000 ppm
  • testo Bluetooth® Connector (0554 3004)
  • Longer sensor service life thanks to automatic sensor protection
  • Integrated fine pressure
  • Versatile probes and fast probe changes: take advantage of quick-change probes and the multi-functional handle for attaching a variety of probe shafts (each available to order separately). You can for instance use longer probe shafts for flue gas pipes with larger diameters or flexible probes for difficult-to-access measuring points
  • Optionally available probes and accessories for further measuring tasks, such as gas flow pressure measurement, gas pipe testing, differential temperature measurement and ambient CO measurement

Smart, intuitive, efficient: easy operation in day-to-day work

  • Smart-touch display for intuitive operation of the combustion analyzer: the display responds without delay – just as easy as on your smartphone
  • Get the measurement result faster: clearly structured measurement menus for all relevant measurements
  • Create documentation (including measuring value, measuring location, customer data) easily on site
  • Save PDF measurement reports directly in the instrument and always have them available
  • Signature function: your customer can sign measurement reports directly on the instrument
  • E-mail measurement reports directly to the office or to customers via WiFi (hotspot)
  • Large 5-inch HD display – enables you to see all the system’s parameters immediately
  • Testo interface function for direct data transfer of measuring values to industry/customer-specific software*
  • Ready to use right away: in standby mode, the Next-Gen testo 300 is ready to measure at the touch of a button. Use it right away with the next customer – because you no longer need to wait for the end of the zeroing phase
  • Integrated Bluetooth® interface: immediate printout of the measuring values on site with the appropriate printer

*Note: the manufacturer has to integrate an interface into the industry software to use the function

Other advantages

  • 10-hour rechargeable battery life: an average measurement period of 2 hours means the combustion analyzer is capable of being used for one week on a full charge
  • Integrated, extra-strong magnets for easy fixing during the measuring process

Applications

  • Flue gas measurement on heating systems
  • Ideal for measurements involving heating systems:
  • high-quality sensors, smart-touch operation, clearly structured measurement menus, creation of documentation on site, e-mailing of reports, large HD display, robust housing
  • Further areas of application:
  • gas flow pressure measurement*, gas pipe test*, differential temperature measurement (flow and return temperature on heating systems)*, ambient CO measurement*, flue draught measurement on heating systems*

* Please note: additional probes or accessories are required for these measurements and have to be ordered separately.

Temperature – Type K TC
Measuring range -40° to 2192 °F / -40 to +1200 °C
Accuracy ±0.9 °F (32.0° to 212.0 °F) / ±0.5 °C (0.0 to +100.0 °C)

±0.5 % of mv (Remaining Range)

Resolution 0.1 °F (-40° to 1831.8 °F) / 0.1 °C (-40 to +999.9 °C)

±1 °F (Remaining Range) / 1 °C (Remaining Range)

Differential Pressure
Measuring range -40 to +80 InH₂O / -100 to +200 hPa
Accuracy ±0.2 InH₂O (0 to +20.0 InH₂O) / ±0.5 hPa (0 to +50.0 hPa)

±1 % of mv (+20.0 to +40.0 InH₂O) / ±1 % of mv (+50.1 to +100.0 hPa)

±1.5 % of mv (+40.0 to +80 InH₂O) / ±1.5 % of mv (+100.1 to +200 hPa)

Resolution 0.00 InH₂O / 0.01 hPa
Flue gas O₂
Measuring range 0 to 21 Vol.%
Accuracy ±0.2 Vol.%
Resolution 0.1 Vol.%
Flue Gas Draft
Measuring range -4.00 to +16 InH₂O / -9.99 to +40 hPa
Accuracy ±0.002 InH₂O (+0 to +0.0 InH₂O) / ±0.005 hPa (+0 to +0.1 hPa)

±0.01 InH₂O (+0.0 to +1.20 InH₂O) / ±0.02 hPa (+0.1 to +3.00 hPa)

±1.5 % of mv (1.20 to +16 InH₂O) / ±1.5 % of mv (3.01 to +40 hPa)

Resolution 0.000 InH₂O (0 to 0.0 InH₂O) / 0.001 hPa (0 to 0.1 hPa)

0.00 InH₂O (Remaining Range) / 0.01 hPa (Remaining Range)

Efficiency (calculated)
Measuring range 0 to 120 %
Resolution 0.1 %
Flue Gas loss (calculated)
Measuring range 0 to 99.9 %
Resolution 0.1 %
Flue Gas CO₂ calculation (calculated from O₂)
Measuring range Display range 0 to CO₂ max
Accuracy ±0.2 Vol.%
Resolution 0.1 Vol.%
Flue gas CO (without H₂-compensation)
Measuring range 0 to 4000 ppm
Accuracy ±20 ppm (0 to 400 ppm)

±5 % of mv (401 to 2000 ppm)

±10 % of mv (2001 to 4000 ppm)

Resolution 1 ppm
Ambient CO
Measuring range 0 to 2000 ppm
Accuracy ±10 ppm (0 to 100 ppm)

±10 % of mv (101 to 2000 ppm)

Resolution 1 ppm
General technical data
Operating humidity 15 to 90 %rH non-condensing
Weight approximately 28.2 oz. / approximately 800 g
Dimensions 9.6 (including probe connection) x 3.9 x 2.3 in. (LxWxH) / 244 (including probe connection) x 98 x 59 mm (LxWxH)
Operating temperature 23° to 113 °F / -5 to +45 °C
Protection class IP40
Product colour black/orange
Display type 5.0″ touch display, HD 1280*720 pixels, IPS (160 k)
Power supply Rechargeable battery, USB mains unit
Authorizations TÜV-tested according to 1st German Federal Immission Control Ordinance (BImSchV) EN 50379, Parts 1-3
Guarantee Gas sensors (O₂, CO) 24 months; rechargeable battery: 12 months; Thermocouple 12 months
Memory 1,000,000 measuring values
Storage battery type Lithium ion battery
Battery life 10 h
Storage temperature -4° to 122 °F / -20 to +50 °C
Charging temperature 32° to 113 °F / 0 to +45 °C
Differential Pressure 4 Pa measurement – Piezoresistive
Measuring Range -0 to +0 InH₂O / -50 to +50 Pa
Accuracy ±0.0 InH₂O (< 0 InH₂O) / ±0.3 Pa (< 10 Pa)

±3 % of mv (Remaining Range)

Resolution 0.0 InH₂O / 0.1 Pa


The Smoke Combustion analyzer with printer enables easy measurement of flue gas, draft, pressure, ambient CO and differential temperature.

The Next-Gen testo 300 combustion analyzer is supplied with O2 and CO sensor (CO range up to 4,000 ppm),combustion probe, testo Bluetooth® Connector, instrument case, printer, and practical accessories.

Impressive measuring technology and quality

  • O2 sensor and CO sensor up to 4,000 ppm
  • testo Bluetooth® Connector (0554 3004)
  • Longer sensor service life thanks to automatic sensor protection
  • Integrated fine pressure
  • Versatile probes and fast probe changes: take advantage of quick-change probes and the multi-functional handle for attaching a variety of probe shafts (each available to order separately). You can for instance use longer probe shafts for flue gas pipes with larger diameters or flexible probes for difficult-to-access measuring points
  • Optionally available probes and accessories for further measuring tasks, such as gas flow pressure measurement, gas pipe testing, differential temperature measurement and ambient CO measurement

Smart, intuitive, efficient: easy operation in day-to-day work

  • Smart-touch display for intuitive operation of the combustion analyzer: the display responds without delay – just as easy as on your smartphone
  • Get the measurement result faster: clearly structured measurement menus for all relevant measurements
  • Create documentation (including measuring value, measuring location, customer data) easily on site
  • Save PDF measurement reports directly in the instrument and always have them available
  • Signature function: your customer can sign measurement reports directly on the instrument
  • E-mail measurement reports directly to the office or to customers via WiFi (hotspot)
  • Large 5-inch HD display – enables you to see all the system’s parameters immediately
  • Testo interface function for direct data transfer of measuring values to industry/customer-specific software*
  • Ready to use right away: in standby mode, the Next-Gen testo 300 is ready to measure at the touch of a button. Use it right away with the next customer – because you no longer need to wait for the end of the zeroing phase
  • Integrated Bluetooth® interface: immediate printout of the measuring values on site with the appropriate printer

*Note: the manufacturer has to integrate an interface into the industry software to use the function

Other advantages

  • 10-hour rechargeable battery life: an average measurement period of 2 hours means the combustion analyzer is capable of being used for one week on a full charge
  • Integrated, extra-strong magnets for easy fixing during the measuring process

Applications

  • Flue gas measurement on heating systems
  • Ideal for measurements involving heating systems:
  • high-quality sensors, smart-touch operation, clearly structured measurement menus, creation of documentation on site, e-mailing of reports, large HD display, robust housing
  • Further areas of application:
  • gas flow pressure measurement*, gas pipe test*, differential temperature measurement (flow and return temperature on heating systems)*, ambient CO measurement*, flue draught measurement on heating systems*

* Please note: additional probes or accessories are required for these measurements and have to be ordered separately.

Temperature – Type K TC
Measuring range -40° to 2192 °F / -40 to +1200 °C
Accuracy ±0.9 °F (32.0° to 212.0 °F) / ±0.5 °C (0.0 to +100.0 °C)

±0.5 % of mv (Remaining Range)

Resolution 0.1 °F (-40° to 1831.8 °F) / 0.1 °C (-40 to +999.9 °C)

±1 °F (Remaining Range) / 1 °C (Remaining Range)

Differential Pressure
Measuring range -40 to +80 InH₂O / -100 to +200 hPa
Accuracy ±0.2 InH₂O (0 to +20.0 InH₂O) / ±0.5 hPa (0 to +50.0 hPa)

±1 % of mv (+20.0 to +40.0 InH₂O) / ±1 % of mv (+50.1 to +100.0 hPa)

±1.5 % of mv (+40.0 to +80 InH₂O) / ±1.5 % of mv (+100.1 to +200 hPa)

Resolution 0.00 InH₂O / 0.01 hPa
Flue gas O₂
Measuring range 0 to 21 Vol.%
Accuracy ±0.2 Vol.%
Resolution 0.1 Vol.%
Flue Gas Draft
Measuring range -4.00 to +16 InH₂O / -9.99 to +40 hPa
Accuracy ±0.002 InH₂O (+0 to +0.0 InH₂O) / ±0.005 hPa (+0 to +0.1 hPa)

±0.01 InH₂O (+0.0 to +1.20 InH₂O) / ±0.02 hPa (+0.1 to +3.00 hPa)

±1.5 % of mv (1.20 to +16 InH₂O) / ±1.5 % of mv (3.01 to +40 hPa)

Resolution 0.000 InH₂O (0 to 0.0 InH₂O) / 0.001 hPa (0 to 0.1 hPa)

0.00 InH₂O (Remaining Range) / 0.01 hPa (Remaining Range)

Efficiency (calculated)
Measuring range 0 to 120 %
Resolution 0.1 %
Flue Gas loss (calculated)
Measuring range 0 to 99.9 %
Resolution 0.1 %
Flue Gas CO₂ calculation (calculated from O₂)
Measuring range Display range 0 to CO₂ max
Accuracy ±0.2 Vol.%
Resolution 0.1 Vol.%
Flue gas CO (without H₂-compensation)
Measuring range 0 to 4000 ppm
Accuracy ±20 ppm (0 to 400 ppm)

±5 % of mv (401 to 2000 ppm)

±10 % of mv (2001 to 4000 ppm)

Resolution 1 ppm
Ambient CO
Measuring range 0 to 2000 ppm
Accuracy ±10 ppm (0 to 100 ppm)

±10 % of mv (101 to 2000 ppm)

Resolution 1 ppm
General technical data
Operating humidity 15 to 90 %rH non-condensing
Weight approximately 28.2 oz. / approximately 800 g
Dimensions 9.6 (including probe connection) x 3.9 x 2.3 in. (LxWxH) / 244 (including probe connection) x 98 x 59 mm (LxWxH)
Operating temperature 23° to 113 °F / -5 to +45 °C
Protection class IP40
Product colour black/orange
Display type 5.0″ touch display, HD 1280*720 pixels, IPS (160 k)
Power supply Rechargeable battery, USB mains unit
Authorizations TÜV-tested according to 1st German Federal Immission Control Ordinance (BImSchV) EN 50379, Parts 1-3
Guarantee Gas sensors (O₂, CO) 24 months; rechargeable battery: 12 months; Thermocouple 12 months
Memory 1,000,000 measuring values
Storage battery type Lithium ion battery
Battery life 10 h
Storage temperature -4° to 122 °F / -20 to +50 °C
Charging temperature 32° to 113 °F / 0 to +45 °C
Differential Pressure 4 Pa measurement – Piezoresistive
Measuring Range -0 to +0 InH₂O / -50 to +50 Pa
Accuracy ±0.0 InH₂O (< 0 InH₂O) / ±0.3 Pa (< 10 Pa)

±3 % of mv (Remaining Range)

Resolution 0.0 InH₂O / 0.1 Pa