GX-3R 4 Gas Monitor LEL/O2/H2S & CO

RKI - GX-3R LEL/O2/H2S
& CO with Li-Ion battery pack & charger

$790.00 CAD

  • 12 months limited warranty
  • Smallest & lightest 4 gas monitor
  • Simultaneous detection of 4 gases
  • H2 Compensated CO sensor available
  • Free Shipping across Canada
CLICK HERE FOR A CALIBRATION CERTIFICATE $110.00 CAD

Support, maintenance, calibration
1 800 463-4363

 

This 4 gas monitor is smaller than many single gas monitors! Presenting the world’s smallest gas detector that you can easily clip within the breathing zone.

The unit simultaneously monitors LEL combustibles, O2, CO (Hydrogen compensated CO also available), and H2S. Using the new generation of microsensors, the GX-3R is the latest evolution in dangerous gas detection equipment. Two active filaments in the sensor increase its resistance to silicone poisoning: if one filament gets poisoned the second one takes over. The all-new electrochemical  O2 sensor has a 3 – 5 year life span.  H2S and CO detection is now available in a combo microsensor.

It simultaneously monitors and displays LEL combustibles, O2, CO (Hydrogen compensated CO also available), and H2S.

Ideal for safety supervisors

If there was a gas alarm event, the instrument was not bump tested, or calibration is due, the 3 LED lights will flash every 30 sec. (interval is adjustable). OSHA defines the breathing zone as a ten-inch radius around the worker’s nose. Air sampling filters can be attached to the collar or lapel.

GX 3R: Features & Benefits

Specifications

Gas Detected (CO) H2 Compensated Carbon Monoxide (CO) Hydrogen Sulfiden (H2S) H2S Only Combustible Gases (Methane as standard)
Dual Sensor
Sensor Slot 1 2
Detection Principle EC Dual EC EC Catalytic combustion
Detection Range (Increments) 0 ~ 2,000 ppm (1 ppm) 0 ~ 200.0 ppm (0.1 ppm) 0 ~ 100% LEL (1% LEL)
Accuracy Statement ± 5% of reading or ± 2 ppm CO ± 5% of reading or ± 5 ppm CO (whichever is greater) ± 5% of reading or ± 2 ppm H2S (whichever is greater) ± 5% of reading or ± 2% LEL (whichever is greater)
Sampling Method Diffusion sampling standard (hand aspirator or clip-on motorized pump optional)
Display Digital LCD displays with 7 segments plus 14 segments plus icon
Preset Alarms (User Adjustable) Overscale alarm (Non-adjustable) 1st alarm: 25.0 ppm 2nd alarm: 50.0 ppm 3rd alarm: 1200.0 ppm TWA alarm: 25.0 ppm STEL alarm: 200.0 ppm Over alarm: 2000.0 ppm 1st alarm: 5.0 ppm 2nd alarm: 30.0 ppm 3rd alarm: 100.0 ppm TWA alarm: 1.0 ppm STEL alarm: 5.0 ppm Over alarm: 200.0 ppm 1st alarm: 10% LEL 2nd alarm: 25% LEL 3rd alarm: 50% LEL Over alarm: 100% LEL
Types of Alarms Gas Alarm: 3 Increasing alarms, STEL, TWA, overscale alarm. O2 decreasing/increasing. Trouble alarm: Sensor disconnection, low battery, a circuit error, a calibration range error
Display of Alarm Gas Alarm: Flashing LEDs, a continuous buzzer (100 dB @ 30 cm), flashing gas value, vibration Trouble alarm: Flashing LEDs, an intermittent buzzer (95 dB @ 30 cm), display of error message
Operating Temp. & Humidity -20°C ~ +50°C [ -4°F ~ +122°F ], 10 to 90% RH, non-condensing (continuous environment) -40°C ~ +60°C [ -40°F ~ +140°F ], 0 to 95% RH, non-condensing (temporary environment, 15 minutes)
Response Time Within 30 seconds (T90)
Power Source Lithium-ion battery, Approx. 25 hours after a 3 hour full charge
Approvals ATEX, CSA (Pending)
Dimension & Weight 2.2” W x 2.55” H x 1.02” D (Approx. 58 W x 65 H x 26 D mm),3.52 ounces (approx. 100 g) without rubber booth 2.4” W x 2.63” H x 1.06” D (Approx. 61 W x 67 H x 27 D mm),3.70 ounces (approx. 105 g) with rubber booth
Case Material Explosion-proof, dust and water-resistant to IP-66/68 (2m,1h) approval. Drop height 23 ft
Controls Two buttons: POWER / MODE, AIR
Datalogging Logs user ID, station ID, Calibration & Bump Test history, Alarm Events & Alarm Interval Trends
Standard Accessories Alligator clip, protective rubber boot, charger, and calibration adapter
Optional Accessories SDM-3R calibration station RP-3R Clip-on sampling pump with 4” rubber nipple, 10’ hose and probe (up to 40’ hose available) Padded carrying case for GX-3R and accessories USB to IrDA downloading cable for datalogger

RK72RAC-00 / MFR:72-RA-C

QUICK TIP:
Measuring Mode Operation
When the GX-3R completes its startup sequence, it is in Measuring Mode. In Measuring Mode the GX-3R continuously monitors the sampled atmosphere and displays the target gas concentrations. The GX-3R is considered to be in Normal Operation if there are no alarm indications.
Heart Symbol: The heart symbol in the upper left corner of the LCD indicates the operation status and blinks when normal. A microprocessor error causes the heart symbol to stop flashing or to disappear.
Check Mark: If BUMP.RMDR is set to ON and if a bump test is not due, a checkmark appears in the upper left corner of the LCD.
“S”: If the instrument is operating in Stealth Mode, an “S” appears at the top of the LCD.
Backlight: In a low-light environment, press and release either button to turn on the display backlight.
Confirmation/Non-Compliance Indicator: If the BEEP menu item in User Mode is set to anything other than OFF, the GX-3R gives periodic indications to confirm that it’s operating or to indicate a non-compliance.

Download Data Sheet
Download Instruction Manual

This 4 gas monitor is smaller than many single gas monitors! Presenting the world’s smallest gas detector that you can easily clip within the breathing zone.

The unit simultaneously monitors LEL combustibles, O2, CO (Hydrogen compensated CO also available), and H2S. Using the new generation of microsensors, the GX-3R is the latest evolution in dangerous gas detection equipment. Two active filaments in the sensor increase its resistance to silicone poisoning: if one filament gets poisoned the second one takes over. The all-new electrochemical  O2 sensor has a 3 – 5 year life span.  H2S and CO detection is now available in a combo microsensor.

It simultaneously monitors and displays LEL combustibles, O2, CO (Hydrogen compensated CO also available), and H2S.

Ideal for safety supervisors

If there was a gas alarm event, the instrument was not bump tested, or calibration is due, the 3 LED lights will flash every 30 sec. (interval is adjustable). OSHA defines the breathing zone as a ten-inch radius around the worker’s nose. Air sampling filters can be attached to the collar or lapel.

GX 3R: Features & Benefits

Specifications

Gas Detected (CO) H2 Compensated Carbon Monoxide (CO) Hydrogen Sulfiden (H2S) H2S Only Combustible Gases (Methane as standard)
Dual Sensor
Sensor Slot 1 2
Detection Principle EC Dual EC EC Catalytic combustion
Detection Range (Increments) 0 ~ 2,000 ppm (1 ppm) 0 ~ 200.0 ppm (0.1 ppm) 0 ~ 100% LEL (1% LEL)
Accuracy Statement ± 5% of reading or ± 2 ppm CO ± 5% of reading or ± 5 ppm CO (whichever is greater) ± 5% of reading or ± 2 ppm H2S (whichever is greater) ± 5% of reading or ± 2% LEL (whichever is greater)
Sampling Method Diffusion sampling standard (hand aspirator or clip-on motorized pump optional)
Display Digital LCD displays with 7 segments plus 14 segments plus icon
Preset Alarms (User Adjustable) Overscale alarm (Non-adjustable) 1st alarm: 25.0 ppm 2nd alarm: 50.0 ppm 3rd alarm: 1200.0 ppm TWA alarm: 25.0 ppm STEL alarm: 200.0 ppm Over alarm: 2000.0 ppm 1st alarm: 5.0 ppm 2nd alarm: 30.0 ppm 3rd alarm: 100.0 ppm TWA alarm: 1.0 ppm STEL alarm: 5.0 ppm Over alarm: 200.0 ppm 1st alarm: 10% LEL 2nd alarm: 25% LEL 3rd alarm: 50% LEL Over alarm: 100% LEL
Types of Alarms Gas Alarm: 3 Increasing alarms, STEL, TWA, overscale alarm. O2 decreasing/increasing. Trouble alarm: Sensor disconnection, low battery, a circuit error, a calibration range error
Display of Alarm Gas Alarm: Flashing LEDs, a continuous buzzer (100 dB @ 30 cm), flashing gas value, vibration Trouble alarm: Flashing LEDs, an intermittent buzzer (95 dB @ 30 cm), display of error message
Operating Temp. & Humidity -20°C ~ +50°C [ -4°F ~ +122°F ], 10 to 90% RH, non-condensing (continuous environment) -40°C ~ +60°C [ -40°F ~ +140°F ], 0 to 95% RH, non-condensing (temporary environment, 15 minutes)
Response Time Within 30 seconds (T90)
Power Source Lithium-ion battery, Approx. 25 hours after a 3 hour full charge
Approvals ATEX, CSA (Pending)
Dimension & Weight 2.2” W x 2.55” H x 1.02” D (Approx. 58 W x 65 H x 26 D mm),3.52 ounces (approx. 100 g) without rubber booth 2.4” W x 2.63” H x 1.06” D (Approx. 61 W x 67 H x 27 D mm),3.70 ounces (approx. 105 g) with rubber booth
Case Material Explosion-proof, dust and water-resistant to IP-66/68 (2m,1h) approval. Drop height 23 ft
Controls Two buttons: POWER / MODE, AIR
Datalogging Logs user ID, station ID, Calibration & Bump Test history, Alarm Events & Alarm Interval Trends
Standard Accessories Alligator clip, protective rubber boot, charger, and calibration adapter
Optional Accessories SDM-3R calibration station RP-3R Clip-on sampling pump with 4” rubber nipple, 10’ hose and probe (up to 40’ hose available) Padded carrying case for GX-3R and accessories USB to IrDA downloading cable for datalogger

RK72RAC-00 / MFR:72-RA-C

QUICK TIP:
Measuring Mode Operation
When the GX-3R completes its startup sequence, it is in Measuring Mode. In Measuring Mode the GX-3R continuously monitors the sampled atmosphere and displays the target gas concentrations. The GX-3R is considered to be in Normal Operation if there are no alarm indications.
Heart Symbol: The heart symbol in the upper left corner of the LCD indicates the operation status and blinks when normal. A microprocessor error causes the heart symbol to stop flashing or to disappear.
Check Mark: If BUMP.RMDR is set to ON and if a bump test is not due, a checkmark appears in the upper left corner of the LCD.
“S”: If the instrument is operating in Stealth Mode, an “S” appears at the top of the LCD.
Backlight: In a low-light environment, press and release either button to turn on the display backlight.
Confirmation/Non-Compliance Indicator: If the BEEP menu item in User Mode is set to anything other than OFF, the GX-3R gives periodic indications to confirm that it’s operating or to indicate a non-compliance.

Download Data Sheet
Download Instruction Manual