Digital manifold

Testo 550s
Leakage test of refrigeration systems

$606.00 CAD

  • 2-way valve block with three connections and sight glass
  • 60 refrigerant profiles stored in the instrument
  • Large 2-line backlit display
CLICK HERE FOR A CALIBRATION CERTIFICATE $110.00 CAD

Support, maintenance, calibration
1 800 463-4363

 

When carrying out maintenance or installation work on refrigeration systems and heat pumps, are you increasingly noticing that the use of analog manifolds is laborious and time-consuming? If so, the testo 550s, our entry-level digital manifold, is the perfect choice for you. This 2-way manifold can be used for 60 refrigerants and offers practical solutions for your everyday work:

  1. Two temperature-compensated pressure sensors ensure fast, precise measurement of high and low pressure, and automatic calculation of the evaporating and condensing temperature
  2. Two connections for external temperature probes: with temperature probes attached (optional), the digital manifold can calculate superheating and subcooling simultaneously and in real-time. This means you can do away with manual comparisons, which are prone to error and obtain fast, accurate results
  3. Leakage test of refrigeration systems: the manifold can carry out a temperature-compensated leakage test of the system for rough tightness testing. For this, the initial system pressure is compared with the system pressure at the end of the measurement, so that the difference (if there is one) can be displayed immediately
  4. Can be used for standard refrigerants: the 60 most common refrigerants are stored in the instrument as standard

You can also view the temperature difference via the 2-way manifold. The automatic heat pump mode, which makes switching over the refrigerant hoses unnecessary, is also really practical.

Digital manifold: sturdy and practical

The Testo 550s digital manifold features a robust 2-way valve block made of metal with 3 connections and 3 hose holders, is easy to handle, and can even withstand harsh environmental conditions. With its solid housing, the instrument is reliably protected against impacts in compliance with protection class IP 42. You can use the suspension hook to secure the manifold during the measuring process. Thanks to the illuminated display, you can read off the readings easily, even in dark environments.

Testo 550s Delivery Scope

Testo 550s digital manifold including calibration protocol and batteries.

Specifications

Temperature
Measuring range -50 to +150 °C
Accuracy ±0.5 °C
Resolution 0.1 °C
Probe connection 2 x plug-in (NTC)
Pressure measurement
Measuring range -1 to +60 bar
Accuracy ±0.5 % fs
Resolution 0.01 bar
Probe connection 3 x 7/16″ – UNF
Overload rel. (high pressure) 65 bar
Vacuum measurement
Measuring range -1 to 0 bar
General technical data
Weight 1060 g
Dimensions 200 x 109 x 63 mm
Operating temperature -20 to +50 °C
Protection class IP42
Product colour Black
Battery life 250 h (without illumination, without Bluetooth®)
Refrigerants in instrument R114; R12; R123; R1233zd; R1234yf; R1234ze; R124; R125; R13; R134a; R22; R23; R290; R32; R401A; R401B; R402A; R402B; R404A; R407A; R407C; R407F; R407H; R408A; R409A; R410A; R414B; R416A; R420A; R421A; R421B; R422B; R422C; R422D; R424A; R427A; R434A; R437A; R438A; R442A; R444B; R448A; R449A; R450A; R452A; R452B; R453a; R454A; R454B; R454C; R455A; R458A; R500; R502; R503; R507; R513A; R600a; R718 (H₂O); R744 (CO₂)
Refrigerants update by Testo Service R11; FX80; I12A; R1150; R1270; R13B1; R14; R142B; R152A; R161; R170; R227; R236fa; R245fa; R401C; R406A; R407B; R407D; R41; R411A; R412A; R413A; R417A; R417B; R417C; R422A; R426A; R508A; R508B; R600; RIS89; SP22
Storage temperature -20 to +60 °C

 

When carrying out maintenance or installation work on refrigeration systems and heat pumps, are you increasingly noticing that the use of analog manifolds is laborious and time-consuming? If so, the testo 550s, our entry-level digital manifold, is the perfect choice for you. This 2-way manifold can be used for 60 refrigerants and offers practical solutions for your everyday work:

  1. Two temperature-compensated pressure sensors ensure fast, precise measurement of high and low pressure, and automatic calculation of the evaporating and condensing temperature
  2. Two connections for external temperature probes: with temperature probes attached (optional), the digital manifold can calculate superheating and subcooling simultaneously and in real-time. This means you can do away with manual comparisons, which are prone to error and obtain fast, accurate results
  3. Leakage test of refrigeration systems: the manifold can carry out a temperature-compensated leakage test of the system for rough tightness testing. For this, the initial system pressure is compared with the system pressure at the end of the measurement, so that the difference (if there is one) can be displayed immediately
  4. Can be used for standard refrigerants: the 60 most common refrigerants are stored in the instrument as standard

You can also view the temperature difference via the 2-way manifold. The automatic heat pump mode, which makes switching over the refrigerant hoses unnecessary, is also really practical.

Digital manifold: sturdy and practical

The Testo 550s digital manifold features a robust 2-way valve block made of metal with 3 connections and 3 hose holders, is easy to handle, and can even withstand harsh environmental conditions. With its solid housing, the instrument is reliably protected against impacts in compliance with protection class IP 42. You can use the suspension hook to secure the manifold during the measuring process. Thanks to the illuminated display, you can read off the readings easily, even in dark environments.

Testo 550s Delivery Scope

Testo 550s digital manifold including calibration protocol and batteries.

Specifications

Temperature
Measuring range -50 to +150 °C
Accuracy ±0.5 °C
Resolution 0.1 °C
Probe connection 2 x plug-in (NTC)
Pressure measurement
Measuring range -1 to +60 bar
Accuracy ±0.5 % fs
Resolution 0.01 bar
Probe connection 3 x 7/16″ – UNF
Overload rel. (high pressure) 65 bar
Vacuum measurement
Measuring range -1 to 0 bar
General technical data
Weight 1060 g
Dimensions 200 x 109 x 63 mm
Operating temperature -20 to +50 °C
Protection class IP42
Product colour Black
Battery life 250 h (without illumination, without Bluetooth®)
Refrigerants in instrument R114; R12; R123; R1233zd; R1234yf; R1234ze; R124; R125; R13; R134a; R22; R23; R290; R32; R401A; R401B; R402A; R402B; R404A; R407A; R407C; R407F; R407H; R408A; R409A; R410A; R414B; R416A; R420A; R421A; R421B; R422B; R422C; R422D; R424A; R427A; R434A; R437A; R438A; R442A; R444B; R448A; R449A; R450A; R452A; R452B; R453a; R454A; R454B; R454C; R455A; R458A; R500; R502; R503; R507; R513A; R600a; R718 (H₂O); R744 (CO₂)
Refrigerants update by Testo Service R11; FX80; I12A; R1150; R1270; R13B1; R14; R142B; R152A; R161; R170; R227; R236fa; R245fa; R401C; R406A; R407B; R407D; R41; R411A; R412A; R413A; R417A; R417B; R417C; R422A; R426A; R508A; R508B; R600; RIS89; SP22
Storage temperature -20 to +60 °C