Wireless temp / humidity Data Loggers for museums, also monitor cumulative luminance and UV

TandD - RTR-574 -RTR-574-S
For museums and exhibitions

$533.50 CAD$642.00 CAD

  • Illuminance: 0 to 130klx
  • UV Intensity: 0 to 30mW/cm2
  • Temperature: 0 to 55°C / -25 to 70°C
  • Humidity: 10 to 95%RH / 0 to 99%RH(-20°C~)

Support, maintenance, calibration
1 800 463-4363

 

These Wireless Data Loggers RTR-500/RTR500B series allows you to mix and match an array of wireless radio communication loggers with various Base Units or Data Collectors to meet your needs.

Records UV, illuminance, temperature and humidity, displays cumulative UV and illuminance.

Logged data can be automatically sent via network or mobile communication to be saved in cloud storage or to a specified location.

 

Benefit

Features

  • 1ch each
  • Measurement Range for Normal Type:
  • Illuminance:  -0 to 130,000 lx
  • UV Intensity: 0 to 30 mW/cm2
  • Temperature: 0 to 55°C
  • Humidity: 10 to 95%RH
  • Measurement Range for S-model :
  • Illuminance:  -0 to 130,000 lx
  • UV Intensity: 0 to 30 mW/cm2
  • Temperature: -30 to 80°C
  • Humidity: 10 to 99%RH
  • While recording possible to view cumulative illuminance and cumulative UV
  • Possible to detect changes in illuminance even under moonlight

RTR-574 loggers have a wireless radio communication range with compatible base units of up to 150m (500ft).

Data can be transmitted from a logger to a base unit and then automatically uploaded to cloud storage or saved to a specified location. Data can also be checked on your PC screen or on site with one of our compatible handheld data collectors.

It is perfect for use in the protection of exhibits and archives in museums and libraries where you wish to manage various measurement points at once.

Base Unit

Data loggers in our RTR-500 Series only function as Remote Units and need to be used with one of the collection devices
(Base Unit).(see complementary products tab)

The collected data can then be transmitted to a PC by a variety of methods such as USB, E-mail, or FTP. Moreover, various functions, such as the monitoring of current readings
and warning notifications, make it a powerful data management system.
* Select a Base Unit according to the type and scale of the measuring environment.

 

RTR-574-S

RTR-574-S loggers have a wireless radio communication range with compatible base units of up to 150m (500ft).

Data can be transmitted from a logger to a base unit and then automatically uploaded to cloud storage or saved to a specified location. Data can also be checked on your PC screen or on site with one of our compatible data collectors.

It is perfect for use in the protection of exhibits and archives in museums and libraries where you wish to manage various measurement points at once.

This model comes with a high precision temperature-humidity sensor, making it perfect for situations where strict temperature and humidity control is required.

Measurement Channels Illuminance, UV Intensity, Temperature, Humidity
Measurement Range

RTR-574

Illuminance: 0 to 130klx
UV Intensity: 0 to 30mW/cm2
Temperature: 0 to 55°C
Humidity: 10 to 95%RH

RTR-574-S (High-Precision)

Illuminance: 0 to 130klx
UV Intensity: 0 to 30mW/cm2
Temperature: -25 to 70°C
Humidity: 0 to 99%RH(-20°C~)
Accuracy

RTR-574

Illuminance: ±5%
UV Intensity: ±5%
Temperature: ±0.5°C
Humidity: ±5%RH

RTR-574-S (High-Precision)

Illuminance: ±5%
UV Intensity: ±5%
Temperature: ±0.3°C
Humidity: ±2.5%RH
LCD Display Measurements, Battery Life Warning, etc.
Logging Capacity 8,000 data sets
Recording Intervals 15 choices from 1 sec. to 60 min.
Recording Mode Endless/Onetime
Comm Interfaces USB, Serial, Short Range Wireless
Power AA Alkaline Battery x 1
Operating Environment Temperature: -10 to 60 °C
Humidity: 90 %RH or less (no condensation)
Dimensions H:55mm × W:78mm × D:18mm
Waterproof Capacity None
Battery Life Approx. 4 months
Accessories Illuminance-UV Sensor, Temperature-Humidity Sensor, etc.


These Wireless Data Loggers RTR-500/RTR500B series allows you to mix and match an array of wireless radio communication loggers with various Base Units or Data Collectors to meet your needs.

Records UV, illuminance, temperature and humidity, displays cumulative UV and illuminance.

Logged data can be automatically sent via network or mobile communication to be saved in cloud storage or to a specified location.

 

Benefit

Features

  • 1ch each
  • Measurement Range for Normal Type:
  • Illuminance:  -0 to 130,000 lx
  • UV Intensity: 0 to 30 mW/cm2
  • Temperature: 0 to 55°C
  • Humidity: 10 to 95%RH
  • Measurement Range for S-model :
  • Illuminance:  -0 to 130,000 lx
  • UV Intensity: 0 to 30 mW/cm2
  • Temperature: -30 to 80°C
  • Humidity: 10 to 99%RH
  • While recording possible to view cumulative illuminance and cumulative UV
  • Possible to detect changes in illuminance even under moonlight

RTR-574 loggers have a wireless radio communication range with compatible base units of up to 150m (500ft).

Data can be transmitted from a logger to a base unit and then automatically uploaded to cloud storage or saved to a specified location. Data can also be checked on your PC screen or on site with one of our compatible handheld data collectors.

It is perfect for use in the protection of exhibits and archives in museums and libraries where you wish to manage various measurement points at once.

Base Unit

Data loggers in our RTR-500 Series only function as Remote Units and need to be used with one of the collection devices
(Base Unit).(see complementary products tab)

The collected data can then be transmitted to a PC by a variety of methods such as USB, E-mail, or FTP. Moreover, various functions, such as the monitoring of current readings
and warning notifications, make it a powerful data management system.
* Select a Base Unit according to the type and scale of the measuring environment.

 

RTR-574-S

RTR-574-S loggers have a wireless radio communication range with compatible base units of up to 150m (500ft).

Data can be transmitted from a logger to a base unit and then automatically uploaded to cloud storage or saved to a specified location. Data can also be checked on your PC screen or on site with one of our compatible data collectors.

It is perfect for use in the protection of exhibits and archives in museums and libraries where you wish to manage various measurement points at once.

This model comes with a high precision temperature-humidity sensor, making it perfect for situations where strict temperature and humidity control is required.

Measurement Channels Illuminance, UV Intensity, Temperature, Humidity
Measurement Range

RTR-574

Illuminance: 0 to 130klx
UV Intensity: 0 to 30mW/cm2
Temperature: 0 to 55°C
Humidity: 10 to 95%RH

RTR-574-S (High-Precision)

Illuminance: 0 to 130klx
UV Intensity: 0 to 30mW/cm2
Temperature: -25 to 70°C
Humidity: 0 to 99%RH(-20°C~)
Accuracy

RTR-574

Illuminance: ±5%
UV Intensity: ±5%
Temperature: ±0.5°C
Humidity: ±5%RH

RTR-574-S (High-Precision)

Illuminance: ±5%
UV Intensity: ±5%
Temperature: ±0.3°C
Humidity: ±2.5%RH
LCD Display Measurements, Battery Life Warning, etc.
Logging Capacity 8,000 data sets
Recording Intervals 15 choices from 1 sec. to 60 min.
Recording Mode Endless/Onetime
Comm Interfaces USB, Serial, Short Range Wireless
Power AA Alkaline Battery x 1
Operating Environment Temperature: -10 to 60 °C
Humidity: 90 %RH or less (no condensation)
Dimensions H:55mm × W:78mm × D:18mm
Waterproof Capacity None
Battery Life Approx. 4 months
Accessories Illuminance-UV Sensor, Temperature-Humidity Sensor, etc.