Tramex concrete determinator inspector kit

Tramex - CDIK
Test of Surface and In-Body concrete Moisture Content in floors and slabs using a unified gravimetric-based testing method

$3,202.00 CAD

  • 12 months limited warranty
  • Calibration Check Plate
  • Infrared Thermometer
  • Hole liners

Support, maintenance, calibration
1 800 463-4363

 

The Tramex concrete determinator inspector kit is the complete concrete moisture test kit

The complete kit for instant and precise testing of both Surface and In-Body concrete Moisture Content in floors and slabs using a unified gravimetric-based testing method. The Tramex CMEX5 digital moisture meter allows for non-destructive quantitative testing of concrete and comparative testing per ASTM F2659.

The reusable Concrete Moisture Determinator Probe used with the CMEX5 allows for in-depth moisture content probe testing within the concrete, down to an extendable depth of up to 4″ (100mm),Diameter 3/4” (19mm). The CMEX5 also incorporates reusable plug-in Hygro-i2 ® RH probes for in-situ testing of concrete. An infrared surface thermometer gives surface temperature and dew point conditions when used in conjunction with the CMEX5 hygrometer. The Concrete Determinator Inspector Kit comes in a protective heavy-duty carrying case with die-cut foam lining.

The Tramex Meters App allows you to GeoTag test results, create, save and share reports and charts, as well as see your meter screen on your phone when using the CMEX5 extension handle.

Kit Contents

  1. Concrete Moisture Encounter X5 –  CMEX5
  2. Free App available for Android and iOS (phone not included)
  3. Concrete Moisture Determinator Probe
  4. 1 x Hygro-i2 ® Reusable Relative Humidity probe
  5. Calibration Check Plate
  6. Infrared Thermometer
  7. Hole liners
  8. Extension Handle

CONCRETE MOISTURE ENCOUNTER X5  – CMEX5 – MEASURING RANGE:

Depth of penetration in concrete: approx.  ¾” (20mm)
Moisture content for Concrete: 0 → 6.9 %
Comparative for Gypsum floor screed: 0 → 12
CM Equiv Anhydrite/Concrete: 0→2.7 / 0→4.3
Reference scale: 0 → 100
Relative Humidity: 0 → 99%
(with optional Hygro-i2 ® probe): Humidity accuracy: 0% → 99%RH +/- 2% @ 25°C / 77°F
Moisture content for wood (with optional wood pin probes): 5 → 30 %

 

CONCRETE MOISTURE PROBE ‘THE DETERMINATOR’ – MEASURING RANGE:

Moisture Content for Concrete with Tramex CMEX5: 0 – 6.9%
Depth of Penetration: 1 1/4” probe depth for concrete between 2” to 4”
2 1/4” probe depth for concrete between 4” to 6”
3 1/4” probe depth for concrete between 6” to 9”
4 1/4” probe depth for concrete between 9” to 11”

 

INFRARED THERMOMETER IRT2

Temperature range: -58ºF ~ 1202ºF (-50 to 650 ºC)
Distance to Spot ratio: D:S = 12:1
Display resolution: 0.1 ºF(0.1ºC)   <1000 1ºC   >1000
Accuracy for targets: Assumes ambient operating temperature of  73 to 77ºF (23 to 25 ºC) -58ºF ~ 68ºF (-50 ~ 20ºC)

±4.5ºF (2.5ºC) 68ºF ~572ºF (20ºC ~300ºC)  ±1.0% ± 1.8ºF (1.0ºC) 572ºF ~ 1202ºF (300ºC ~650ºC) ±1.5%

Repeatability: -58~68ºF (-50~20ºC)  :  ± 2.3ºF (1.3ºC) 68~1202ºF (20~650ºC) : ±0.5% or ±0.9ºF (0.5ºC)
Response time: 150ms
Spectral response: 8~14um
Emissivity: Digitally adjustable from 0.10 to 1.0
Over range indication: LCD will show “—-”
Polarity: Automatic (no indication for positive polarity); Minus (-) sign for negative polarity
Diode laser output: <1mW,Wavelength 630~670nm, Class 2 laser product
Operating temp.: 32 to 122ºF ( 0 to 50ºC)
Storage temp.: 14 to 140ºF (–10 to 60ºC)
Relative humidity: 10%~90%RH operating, <80%RH storage
Power supply: 9V battery, NEDA 1604A or IEC 6LR61, or equivalent
Safety: “ CE ” Comply with EMC

SPECIFICATIONS OF KIT:

Size: 17.1” x 14.2” x 5.5” (43.5cm x 36cm x 14cm)
Weight: 7.9 lbs (3.6 kg)
Power: 2 x AA batteries, 1 x 9 volt PP3 battery

 


The Tramex concrete determinator inspector kit is the complete concrete moisture test kit

The complete kit for instant and precise testing of both Surface and In-Body concrete Moisture Content in floors and slabs using a unified gravimetric-based testing method. The Tramex CMEX5 digital moisture meter allows for non-destructive quantitative testing of concrete and comparative testing per ASTM F2659.

The reusable Concrete Moisture Determinator Probe used with the CMEX5 allows for in-depth moisture content probe testing within the concrete, down to an extendable depth of up to 4″ (100mm),Diameter 3/4” (19mm). The CMEX5 also incorporates reusable plug-in Hygro-i2 ® RH probes for in-situ testing of concrete. An infrared surface thermometer gives surface temperature and dew point conditions when used in conjunction with the CMEX5 hygrometer. The Concrete Determinator Inspector Kit comes in a protective heavy-duty carrying case with die-cut foam lining.

The Tramex Meters App allows you to GeoTag test results, create, save and share reports and charts, as well as see your meter screen on your phone when using the CMEX5 extension handle.

Kit Contents

  1. Concrete Moisture Encounter X5 –  CMEX5
  2. Free App available for Android and iOS (phone not included)
  3. Concrete Moisture Determinator Probe
  4. 1 x Hygro-i2 ® Reusable Relative Humidity probe
  5. Calibration Check Plate
  6. Infrared Thermometer
  7. Hole liners
  8. Extension Handle

CONCRETE MOISTURE ENCOUNTER X5  – CMEX5 – MEASURING RANGE:

Depth of penetration in concrete: approx.  ¾” (20mm)
Moisture content for Concrete: 0 → 6.9 %
Comparative for Gypsum floor screed: 0 → 12
CM Equiv Anhydrite/Concrete: 0→2.7 / 0→4.3
Reference scale: 0 → 100
Relative Humidity: 0 → 99%
(with optional Hygro-i2 ® probe): Humidity accuracy: 0% → 99%RH +/- 2% @ 25°C / 77°F
Moisture content for wood (with optional wood pin probes): 5 → 30 %

 

CONCRETE MOISTURE PROBE ‘THE DETERMINATOR’ – MEASURING RANGE:

Moisture Content for Concrete with Tramex CMEX5: 0 – 6.9%
Depth of Penetration: 1 1/4” probe depth for concrete between 2” to 4”
2 1/4” probe depth for concrete between 4” to 6”
3 1/4” probe depth for concrete between 6” to 9”
4 1/4” probe depth for concrete between 9” to 11”

 

INFRARED THERMOMETER IRT2

Temperature range: -58ºF ~ 1202ºF (-50 to 650 ºC)
Distance to Spot ratio: D:S = 12:1
Display resolution: 0.1 ºF(0.1ºC)   <1000 1ºC   >1000
Accuracy for targets: Assumes ambient operating temperature of  73 to 77ºF (23 to 25 ºC) -58ºF ~ 68ºF (-50 ~ 20ºC)

±4.5ºF (2.5ºC) 68ºF ~572ºF (20ºC ~300ºC)  ±1.0% ± 1.8ºF (1.0ºC) 572ºF ~ 1202ºF (300ºC ~650ºC) ±1.5%

Repeatability: -58~68ºF (-50~20ºC)  :  ± 2.3ºF (1.3ºC) 68~1202ºF (20~650ºC) : ±0.5% or ±0.9ºF (0.5ºC)
Response time: 150ms
Spectral response: 8~14um
Emissivity: Digitally adjustable from 0.10 to 1.0
Over range indication: LCD will show “—-”
Polarity: Automatic (no indication for positive polarity); Minus (-) sign for negative polarity
Diode laser output: <1mW,Wavelength 630~670nm, Class 2 laser product
Operating temp.: 32 to 122ºF ( 0 to 50ºC)
Storage temp.: 14 to 140ºF (–10 to 60ºC)
Relative humidity: 10%~90%RH operating, <80%RH storage
Power supply: 9V battery, NEDA 1604A or IEC 6LR61, or equivalent
Safety: “ CE ” Comply with EMC

SPECIFICATIONS OF KIT:

Size: 17.1” x 14.2” x 5.5” (43.5cm x 36cm x 14cm)
Weight: 7.9 lbs (3.6 kg)
Power: 2 x AA batteries, 1 x 9 volt PP3 battery