Thermo recorder for Vaccine Monitoring

TandD - TR71A2, TR75A2
Access Wide Range Temperature Data Anytime from Anywhere

Price range: $322.90 CAD through $365.10 CAD

Support, maintenance, calibration –
1 800 463-4363

Access Wide Range Temperature Data Anytime from Anywhere

Model: TR71A2

  • The TR71A2 with two sensor connections can measure temperatures from -60 up to 155℃.
  • The wide range of optional sensors provides increased measurement flexibility.
  • The LCD screen allows the simultaneous display of either the current values of two channels, the highest and lowest values of channel 1, or the highest and lowest values of channel 2.
  • The ALM icon on the LCD alerts the user to the occurrence of an alarm.
  • Use the wireless LAN feature (compatible with enterprise communication) to auto-upload data to the cloud for anytime, anywhere access and receive warning notifications. By using Bluetooth or USB, you can configure device settings, generate reports, download data, and view the uploaded data.
  • A USB cable (option US-15C) is required to connect the device to a PC.

Model: TR75A2

The TR75A2 is a temperature logger with two thermocouple (K, J, T, E, S, R) sensor connections. It is capable of measuring temperatures ranging from -199 to 1760°C, and can be used in very high temperatures, such as in a plant furnace or in deep freezers, where temperatures reach very low levels.

Functional buttons on the device allow you to make settings and start/stop recording. Use the wireless LAN feature (compatible with enterprise communication) to auto-upload data to the cloud for anytime, anywhere access and receive warning notifications. By using Bluetooth or USB, you can configure device settings, generate reports, download data, and view the uploaded data. You can download the recorded data and change the device settings on a PC via USB Connection. A USB cable (option US-15C) is required to connect the device to a PC.

The software application used with the TR75A2 has a “Vaccine Mode”, which meets or exceeds CDC requirements for VFC, and is suitable for monitoring and recording vaccine temperatures. TR75A2 is useful not only in pharmaceutical and medical research labs, hospitals, but also in factories and other facilities.

Features

The TR71A2 and TR75A2 use a wireless LAN access point to auto-upload recorded data and warning notifications to our free-of-charge cloud-based “T&D WebStorage Service”. You can download data and configure device settings using our dedicated app “TR7 for Windows (for Windows)” or “T&D Thermo (for smartphone/tablet)”. By using our Windows software “T&D Graph”, you can easily view and analyze data from a PC.

Specifications

Models TR71A2 TR75A2
Measurement Channels Temperature 2ch Temperature 2ch
Sensor Thermistor Thermocouple:
Type K, J, T, E, S, R (*1)
Measurement Units °C, °F °C, °F
Measurement Range Internal Sensor -10 to 60 °C (*2)
External Sensor 40 to 110 °C (Supplied Sensor)
-60 to 155 °C (Optional Sensor: Fluoropolymer Coated Type)
Type K: -199 to 1370 °C
Type J : -199 to 1200 °C
Type T: -199 to 400 °C
Type E: -199 to 1000 °C
Type S: -50 to 1760 °C
Type R: -50 to 1760 °C
Accuracy (Supplied Sensor)
Avg. ± 0.3 °C at -20 to 80 °C
Avg. ± 0.5 °C at -40 to -20 °C,
80 to 110  °C
Thermocouple Measurement
(Sensor inaccuracies not included)
Type K, J, T, E:
± (0.5 + 0.003 × t) °C at -100 °C or above
Type S, R:
± (1.5 + 0.003 × t) °C at 100 °C or above
t = absolute value of measurement in °C
Cold Junction Compensation
±0.5 ℃ at 10 to 40 °C
±0.8 ℃
other temperatures within the operating environment of the logger
Measurement Resolution 0.1 °C Type K, J, T, E: 0.1 °C
Type S, R: Approx. 0.2 °C
Responsiveness (Supplied Sensor)
Response Time (90 %): Approx. 190 sec.
Logging Capacity 30,000 data sets (One data set consists of readings for all channels.)
Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.
Recording Mode Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full)
Measurement Mode Normal Mode: Max/Min values and ALM display based on the readings on the LCD
Vaccine Mode (*4): Max/Min values and ALM display based on the recorded values
LCD Display Items Measurements, ALM Display, Recording Status, Recording Mode, Battery Warning Mark, Communication Status, etc.
Measurements: Ch1 & Ch2 current values / Ch1 Max & Min values / Ch2 Max & Min values
Display Pattern: Alternating or Fixed display
Auto-upload Interval Select from 15 choices: OFF (No auto-upload),1, 2, 5, 10, 15, 20, 30 min. or 1, 2, 3, 4, 6, 12, 24 hrs.
Communication Interfaces Wireless LAN Communication: IEEE 802.11b/g/n (2.4 GHz only)
Security: WPA-PSK(AES/TKIP),WPA2-PSK(AES/TKIP),WPA2-EAP(AES/TKIP)
WPS 2.0: Push Button Configuration
IEEE 802.1X Authentication: EAP-TLS, EAP-PEAP(MSCHAPv2) (*5)
Protocol (*6): HTTP, HTTPS, SNTP, DHCP, DNS
Bluetooth Communication: Bluetooth 4.2 (Bluetooth Low Energy)
USB Communication: USB 2.0 (Mini-B connector)
Power Battery: AA Alkaline LR6 x 2, AA Ni-MH x 2
External: USB Bus 5V 200mA, AC Adaptor (AD-05A2 or AD-05C2) (*7)
Battery Life (*8) Power Saving Settings: OFF
Approx. 5 days
(Auto-Upload Interval 1 min, Rec Interval ≥ 1 min)
Approx. 7 months
(Auto-Upload Interval 1 hr, Rec Interval ≥ 1 min)
Approx. 18 months
(Auto-Upload Interval ≥ 6 hr, Rec Interval ≥ 1 min)
Power Saving Settings: ON (Auto-Upload Pause for 12 hours)
Approx. 10 days
(Auto-Upload interval 1 min, Rec Interval ≥ 1 min)
Approx. 12 months
(Auto-Upload interval 1 hr, Rec Interval ≥ 1 min)
Approx. 18 months
(Auto-Upload interval 3 hr, Rec Interval ≥ 1 min)
1.2 times longer with Bluetooth OFF
Approx. 18 months with Bluetooth & Auto-Upload OFF
Dimensions H 58 mm x W 78 mm x D 26 mm
Weight Approx. 55 g
Operating Environment Temperature: -10 to 60 °C, Humidity: 90 %RH or less (no condensation)
Included Items Temperature Sensor
TR-0106 x 2
(Sensor not provided)
AA Alkaline Battery LR6 x 2, Registration Code Label, Manual Set (Warranty Included)
Software (*9) PC Software (Windows)
TR7 for Windows (*10),T&D Graph, T&D Data Server
Mobile Application (iOS, Android)
T&D Thermo

 

  1. Products do not include thermocouple sensors. Compatible wire sizes are as follows. Single Wire : Ø0.32 to Ø0.65 mm (AWG 28 – 22),Twisted Wire : 0.08 to 0.32
    mm2 (AWG 28 – 22),Ø0.12 mm or more in diameter, and Stripping Length : 9 to 10 mm.
  2. When Auto Upload is used frequently, the measurement of the internal sensor may rise by around 0.3 °C.
    When using external power, the data logger itself generates heat and the internal sensor will report a temperature much higher than ambient; we recommend using
    an external temperature sensor in this case.
  3. When continually used in environments with temperatures above 60 °C, accuracy of humidity measurements will decrease over time. Also, humidity cannot be measured at temperatures below -20 °C.
  4. Vaccine mode complies with the CDC (Centers for Disease Control and Prevention) requirements for vaccine management.
  5. When using EAP-PEAP, server certificate verification using the CA certificate is not available.
  6. Client function. Only HTTP proxy is supported (not HTTPS).
  7. The optional AC adaptor “AD-05A2” (Type A Plug) can be used in the USA and Canada, and “AD-05C2” (Type C Plug) in Europe. For usage in other countries, please contact your local distributor.
  8. Battery life in the table above is for two AA Alkaline type batteries, and varies depending upon multiple factors including frequency of communication, network environment, ambient temperature, recording interval, and battery performance. All estimates are based on operations carried out with a new battery and are in no way a
    guarantee of actual battery life.
  9. Free software download and information on OS compatibility is available on the Software page of our website at https://tandd.com/software/
  10. TR7 for Windows requires a PC with Bluetooth capability (4.0 or above) or a USB communication cable (available as option: US-15C).
    The specifications listed above are subject to change without notice.

 

Access Wide Range Temperature Data Anytime from Anywhere

Model: TR71A2

  • The TR71A2 with two sensor connections can measure temperatures from -60 up to 155℃.
  • The wide range of optional sensors provides increased measurement flexibility.
  • The LCD screen allows the simultaneous display of either the current values of two channels, the highest and lowest values of channel 1, or the highest and lowest values of channel 2.
  • The ALM icon on the LCD alerts the user to the occurrence of an alarm.
  • Use the wireless LAN feature (compatible with enterprise communication) to auto-upload data to the cloud for anytime, anywhere access and receive warning notifications. By using Bluetooth or USB, you can configure device settings, generate reports, download data, and view the uploaded data.
  • A USB cable (option US-15C) is required to connect the device to a PC.

Model: TR75A2

The TR75A2 is a temperature logger with two thermocouple (K, J, T, E, S, R) sensor connections. It is capable of measuring temperatures ranging from -199 to 1760°C, and can be used in very high temperatures, such as in a plant furnace or in deep freezers, where temperatures reach very low levels.

Functional buttons on the device allow you to make settings and start/stop recording. Use the wireless LAN feature (compatible with enterprise communication) to auto-upload data to the cloud for anytime, anywhere access and receive warning notifications. By using Bluetooth or USB, you can configure device settings, generate reports, download data, and view the uploaded data. You can download the recorded data and change the device settings on a PC via USB Connection. A USB cable (option US-15C) is required to connect the device to a PC.

The software application used with the TR75A2 has a “Vaccine Mode”, which meets or exceeds CDC requirements for VFC, and is suitable for monitoring and recording vaccine temperatures. TR75A2 is useful not only in pharmaceutical and medical research labs, hospitals, but also in factories and other facilities.

Features

The TR71A2 and TR75A2 use a wireless LAN access point to auto-upload recorded data and warning notifications to our free-of-charge cloud-based “T&D WebStorage Service”. You can download data and configure device settings using our dedicated app “TR7 for Windows (for Windows)” or “T&D Thermo (for smartphone/tablet)”. By using our Windows software “T&D Graph”, you can easily view and analyze data from a PC.

Specifications

Models TR71A2 TR75A2
Measurement Channels Temperature 2ch Temperature 2ch
Sensor Thermistor Thermocouple:
Type K, J, T, E, S, R (*1)
Measurement Units °C, °F °C, °F
Measurement Range Internal Sensor -10 to 60 °C (*2)
External Sensor 40 to 110 °C (Supplied Sensor)
-60 to 155 °C (Optional Sensor: Fluoropolymer Coated Type)
Type K: -199 to 1370 °C
Type J : -199 to 1200 °C
Type T: -199 to 400 °C
Type E: -199 to 1000 °C
Type S: -50 to 1760 °C
Type R: -50 to 1760 °C
Accuracy (Supplied Sensor)
Avg. ± 0.3 °C at -20 to 80 °C
Avg. ± 0.5 °C at -40 to -20 °C,
80 to 110  °C
Thermocouple Measurement
(Sensor inaccuracies not included)
Type K, J, T, E:
± (0.5 + 0.003 × t) °C at -100 °C or above
Type S, R:
± (1.5 + 0.003 × t) °C at 100 °C or above
t = absolute value of measurement in °C
Cold Junction Compensation
±0.5 ℃ at 10 to 40 °C
±0.8 ℃
other temperatures within the operating environment of the logger
Measurement Resolution 0.1 °C Type K, J, T, E: 0.1 °C
Type S, R: Approx. 0.2 °C
Responsiveness (Supplied Sensor)
Response Time (90 %): Approx. 190 sec.
Logging Capacity 30,000 data sets (One data set consists of readings for all channels.)
Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.
Recording Mode Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full)
Measurement Mode Normal Mode: Max/Min values and ALM display based on the readings on the LCD
Vaccine Mode (*4): Max/Min values and ALM display based on the recorded values
LCD Display Items Measurements, ALM Display, Recording Status, Recording Mode, Battery Warning Mark, Communication Status, etc.
Measurements: Ch1 & Ch2 current values / Ch1 Max & Min values / Ch2 Max & Min values
Display Pattern: Alternating or Fixed display
Auto-upload Interval Select from 15 choices: OFF (No auto-upload),1, 2, 5, 10, 15, 20, 30 min. or 1, 2, 3, 4, 6, 12, 24 hrs.
Communication Interfaces Wireless LAN Communication: IEEE 802.11b/g/n (2.4 GHz only)
Security: WPA-PSK(AES/TKIP),WPA2-PSK(AES/TKIP),WPA2-EAP(AES/TKIP)
WPS 2.0: Push Button Configuration
IEEE 802.1X Authentication: EAP-TLS, EAP-PEAP(MSCHAPv2) (*5)
Protocol (*6): HTTP, HTTPS, SNTP, DHCP, DNS
Bluetooth Communication: Bluetooth 4.2 (Bluetooth Low Energy)
USB Communication: USB 2.0 (Mini-B connector)
Power Battery: AA Alkaline LR6 x 2, AA Ni-MH x 2
External: USB Bus 5V 200mA, AC Adaptor (AD-05A2 or AD-05C2) (*7)
Battery Life (*8) Power Saving Settings: OFF
Approx. 5 days
(Auto-Upload Interval 1 min, Rec Interval ≥ 1 min)
Approx. 7 months
(Auto-Upload Interval 1 hr, Rec Interval ≥ 1 min)
Approx. 18 months
(Auto-Upload Interval ≥ 6 hr, Rec Interval ≥ 1 min)
Power Saving Settings: ON (Auto-Upload Pause for 12 hours)
Approx. 10 days
(Auto-Upload interval 1 min, Rec Interval ≥ 1 min)
Approx. 12 months
(Auto-Upload interval 1 hr, Rec Interval ≥ 1 min)
Approx. 18 months
(Auto-Upload interval 3 hr, Rec Interval ≥ 1 min)
1.2 times longer with Bluetooth OFF
Approx. 18 months with Bluetooth & Auto-Upload OFF
Dimensions H 58 mm x W 78 mm x D 26 mm
Weight Approx. 55 g
Operating Environment Temperature: -10 to 60 °C, Humidity: 90 %RH or less (no condensation)
Included Items Temperature Sensor
TR-0106 x 2
(Sensor not provided)
AA Alkaline Battery LR6 x 2, Registration Code Label, Manual Set (Warranty Included)
Software (*9) PC Software (Windows)
TR7 for Windows (*10),T&D Graph, T&D Data Server
Mobile Application (iOS, Android)
T&D Thermo

 

  1. Products do not include thermocouple sensors. Compatible wire sizes are as follows. Single Wire : Ø0.32 to Ø0.65 mm (AWG 28 – 22),Twisted Wire : 0.08 to 0.32
    mm2 (AWG 28 – 22),Ø0.12 mm or more in diameter, and Stripping Length : 9 to 10 mm.
  2. When Auto Upload is used frequently, the measurement of the internal sensor may rise by around 0.3 °C.
    When using external power, the data logger itself generates heat and the internal sensor will report a temperature much higher than ambient; we recommend using
    an external temperature sensor in this case.
  3. When continually used in environments with temperatures above 60 °C, accuracy of humidity measurements will decrease over time. Also, humidity cannot be measured at temperatures below -20 °C.
  4. Vaccine mode complies with the CDC (Centers for Disease Control and Prevention) requirements for vaccine management.
  5. When using EAP-PEAP, server certificate verification using the CA certificate is not available.
  6. Client function. Only HTTP proxy is supported (not HTTPS).
  7. The optional AC adaptor “AD-05A2” (Type A Plug) can be used in the USA and Canada, and “AD-05C2” (Type C Plug) in Europe. For usage in other countries, please contact your local distributor.
  8. Battery life in the table above is for two AA Alkaline type batteries, and varies depending upon multiple factors including frequency of communication, network environment, ambient temperature, recording interval, and battery performance. All estimates are based on operations carried out with a new battery and are in no way a
    guarantee of actual battery life.
  9. Free software download and information on OS compatibility is available on the Software page of our website at https://tandd.com/software/
  10. TR7 for Windows requires a PC with Bluetooth capability (4.0 or above) or a USB communication cable (available as option: US-15C).
    The specifications listed above are subject to change without notice.