Features – data logging gas monitor
Measures and records oxygen (O2)、carbon monoxide (CO)、carbon dioxide (CO2), relative humidity and temperature.
High-precision gas sensor
Display of Max/Min and average values
Adjustable audible alarm for O2, CO and CO2
Backlit display Adjustable auto shut-off function
Mini USB interface connections
Automatic power-down
What is the best co2 monitor? – the one that meets the necessary precision criteria required for your project. Please see below if this is the case:
| O2 Measurement | |
| Oxygen Range | 1﹣30% vol.O2 |
| Oxygen Resolution | 0.10% |
| Oxygen Respond Time | <15 Seconds |
| CO Measurement | |
| Carbon Monoxide(CO) Range | 0﹣1000 ppm |
| Carbon Monoxide(CO) Accuracy | ±5%F.S |
| Carbon Monoxide(CO) Resolution | 1 ppm |
| Carbon Monoxide(CO) Respond time | <2 Seconds |
| CO2, Measurement | |
| Carbon Dioxide(CO2) Range | 0﹣9999ppm CO2 |
| Carbon Dioxide(CO2) Resolution | 1 ppm |
| Carbon Dioxide(CO2) Accuracy | ±75ppm or ±5% of reading |
| Carbon Dioxide(CO2) Respond time | 120 Seconds |
| Temperature & Humidity Measurement | |
| Temperature Range | 0℃ to 50℃(32℉ to 122℉) |
| Temperature Resolution | 0.1℃/℉ |
| Temperature Accuracy | ±1℃ |
| Humidity Range | 0 to 100% RH |
| Humidity Resolution | 0.1%RH |
| Humidity Accuracy | ±3.5%RH @ 20 to 80% RH ±5%RH @ 0 to 20%RH or 80 to 100%RH |
| Operate Environment | 0℃ to 50℃(32℉ to 122℉)at<90%RH |
Features – data logging gas monitor
Measures and records oxygen (O2)、carbon monoxide (CO)、carbon dioxide (CO2), relative humidity and temperature.
High-precision gas sensor
Display of Max/Min and average values
Adjustable audible alarm for O2, CO and CO2
Backlit display Adjustable auto shut-off function
Mini USB interface connections
Automatic power-down
What is the best co2 monitor? – the one that meets the necessary precision criteria required for your project. Please see below if this is the case:
| O2 Measurement | |
| Oxygen Range | 1﹣30% vol.O2 |
| Oxygen Resolution | 0.10% |
| Oxygen Respond Time | <15 Seconds |
| CO Measurement | |
| Carbon Monoxide(CO) Range | 0﹣1000 ppm |
| Carbon Monoxide(CO) Accuracy | ±5%F.S |
| Carbon Monoxide(CO) Resolution | 1 ppm |
| Carbon Monoxide(CO) Respond time | <2 Seconds |
| CO2, Measurement | |
| Carbon Dioxide(CO2) Range | 0﹣9999ppm CO2 |
| Carbon Dioxide(CO2) Resolution | 1 ppm |
| Carbon Dioxide(CO2) Accuracy | ±75ppm or ±5% of reading |
| Carbon Dioxide(CO2) Respond time | 120 Seconds |
| Temperature & Humidity Measurement | |
| Temperature Range | 0℃ to 50℃(32℉ to 122℉) |
| Temperature Resolution | 0.1℃/℉ |
| Temperature Accuracy | ±1℃ |
| Humidity Range | 0 to 100% RH |
| Humidity Resolution | 0.1%RH |
| Humidity Accuracy | ±3.5%RH @ 20 to 80% RH ±5%RH @ 0 to 20%RH or 80 to 100%RH |
| Operate Environment | 0℃ to 50℃(32℉ to 122℉)at<90%RH |