Data logger

Lascar Electronics - EL-USB-TC-LCD/EL-USB-TC/EL-USB-2-LCD
J, K or T-type thermocouple

$190.00 CAD$222.50 CAD

  • 12 months limited warranty
  • Display status indication
  • LED status indication
  • An easy set up
CLICK HERE TO ADD A CALIBRATION CERTIFICATE $105.00 CAD

What model suits me best?
1 800 463-4363

This data logger measures and stores more than 32,000 temperature readings from a J, K, or T-type thermocouple at a resolution of 0.5°C (1°F)

It comes supplied with a K-type thermocouple capable of measuring from 0 to +200°C (32 to +392°F). Your application will determine which probe is most suitable based on temperature range, accuracy, form, and price. A wide variety of alternative thermocouples are available. Please call Lascar for vendor recommendations. The user can easily set up the logger and view downloaded data by plugging the data logger into a PC’s USB port and using the free EasyLog software. Data can then be graphed, printed, and exported to other applications for detailed analysis. The data logger is supplied with a lithium metal battery which typically gives 2 years’ logging life.

Compatible with K, J, and T-type thermocouples

  • Compatible with K, J, and T-type thermocouples with miniature thermocouple plug connection
  • Stores over 32,000 readings
  • EasyLog software available as a free download
  • Supplied with 1.5m K-type thermocouple probe with 0 to 200°C (32 to 392°F) measurement range
  • Logging rates between 1 second and 12 hours
  • Immediate and delayed logging start
  • User-programmable alarm thresholds
  • Status indication via red and green LEDs

EasyLog USB Data Logger Setup

Lascar EL-USB-2-LCD – For temperature, relative humidity, and dew point

The user can easily configure the recorder and view the downloaded data by plugging it into a PC’s USB port and using the free EasyLog software. The data, including the calculated dew point, can then be graphically represented, printed and exported to other applications for detailed analysis. The high-contrast LCD monitor can display a variety of temperature and humidity information. At the touch of a button, the user can switch between the current temperature and humidity and the maximum and minimum values recorded for temperature and humidity. The data logger is supplied with a lithium metal battery, which gives it a lifetime of up to 2 years. The recorder is protected against water and dust ingress according to IP67 when the cap is installed.

Features

  •  Measuring range from -35 to + 80 ° C (-31 to + 176 ° F) and from 0 to 100% RH
  •  Stores more than 16,000 temperature and humidity readings
  •  EasyLog software available for free download
  •  High-contrast LCD with two-and-a-half digit temperature and humidity display
  •  Recording rate between 10 seconds and 12 hours
  •  Immediate, delayed, and push-to-start logging
  •  User-programmable alarm thresholds for temperature and humidity
  •  Status indication by red/green LED
  •  Environmental protection according to IP67

 

Models EL-USB-TC 

With USB

EL-USB-2-LCD  

For temperature, relative humidity, and dew point

EL-USB-TC-LCD  

With LCD and USB

Temperature
Measurement Range Type K (supplied) 0 to 200°C (32 to 392°F)

K type -200 to +1350°C / -328 to +2462°F

J type -200 à +1190°C / -328 à +2174°F

T Type -200 à +390°C / -328 à +734°F

-35° C to 80° C (-31° F to 176° F) Type K (supplied) 0 to 200°C (32 to 392°F)

K type -200 to +1350°C / -328 to +2462°F

J type -200 à +1190°C / -328 à +2174°F

T Type -200 à +390°C / -328 à +734°F

Internal resolution  0.5 ° C (1 ° F)
Accuracy (overall error) ±1°C / ±2°F (data logger only – thermocouple error not included) 0.55 ° C (1.04 ° F) typical (5 à 60 ° C) ±1°C / ±2°F (data logger only – thermocouple error not included)
Long term stability <0.02 ° C (0.04 ° F) / year
Relative Humidity:
Measurement range 0 à 100% HR
Internal resolution 0,5% HR
Accuracy (overall error) 2.25% RH typical (20 to 80% RH)
Long term stability <0.25% RH / year
Logging Rate User selectable between 10 seconds and 12 hours User selectable between 10 seconds and 12 hours User selectable between 10 seconds and 12 hours
Battery Life 2 years 2 years 2 years
Readings 32 510 16 000 32 510

QUICK TIP:

BATTERY INFORMATION
Replacement

  • We recommend that you replace the battery annually, or prior to logging critical data. Only use 3.6V ½AA lithium metal batteries.
    The data logger does not lose its stored readings when the battery is discharged or replaced; however, the data logging process will
    stop and will not resume until the battery is replaced and the logger restarted by EL-WIN-USB or an EL-DataPad.
  • Before replacing the battery, remove the data logger from the PC. Please note that leaving the data logger plugged into the USB
    port for extended periods will cause some of the battery capacity to be lost.

Download Data Sheet
Download Instruction Manual

This data logger measures and stores more than 32,000 temperature readings from a J, K, or T-type thermocouple at a resolution of 0.5°C (1°F)

It comes supplied with a K-type thermocouple capable of measuring from 0 to +200°C (32 to +392°F). Your application will determine which probe is most suitable based on temperature range, accuracy, form, and price. A wide variety of alternative thermocouples are available. Please call Lascar for vendor recommendations. The user can easily set up the logger and view downloaded data by plugging the data logger into a PC’s USB port and using the free EasyLog software. Data can then be graphed, printed, and exported to other applications for detailed analysis. The data logger is supplied with a lithium metal battery which typically gives 2 years’ logging life.

Compatible with K, J, and T-type thermocouples

  • Compatible with K, J, and T-type thermocouples with miniature thermocouple plug connection
  • Stores over 32,000 readings
  • EasyLog software available as a free download
  • Supplied with 1.5m K-type thermocouple probe with 0 to 200°C (32 to 392°F) measurement range
  • Logging rates between 1 second and 12 hours
  • Immediate and delayed logging start
  • User-programmable alarm thresholds
  • Status indication via red and green LEDs

EasyLog USB Data Logger Setup

Lascar EL-USB-2-LCD – For temperature, relative humidity, and dew point

The user can easily configure the recorder and view the downloaded data by plugging it into a PC’s USB port and using the free EasyLog software. The data, including the calculated dew point, can then be graphically represented, printed and exported to other applications for detailed analysis. The high-contrast LCD monitor can display a variety of temperature and humidity information. At the touch of a button, the user can switch between the current temperature and humidity and the maximum and minimum values recorded for temperature and humidity. The data logger is supplied with a lithium metal battery, which gives it a lifetime of up to 2 years. The recorder is protected against water and dust ingress according to IP67 when the cap is installed.

Features

  •  Measuring range from -35 to + 80 ° C (-31 to + 176 ° F) and from 0 to 100% RH
  •  Stores more than 16,000 temperature and humidity readings
  •  EasyLog software available for free download
  •  High-contrast LCD with two-and-a-half digit temperature and humidity display
  •  Recording rate between 10 seconds and 12 hours
  •  Immediate, delayed, and push-to-start logging
  •  User-programmable alarm thresholds for temperature and humidity
  •  Status indication by red/green LED
  •  Environmental protection according to IP67

 

Models EL-USB-TC 

With USB

EL-USB-2-LCD  

For temperature, relative humidity, and dew point

EL-USB-TC-LCD  

With LCD and USB

Temperature
Measurement Range Type K (supplied) 0 to 200°C (32 to 392°F)

K type -200 to +1350°C / -328 to +2462°F

J type -200 à +1190°C / -328 à +2174°F

T Type -200 à +390°C / -328 à +734°F

-35° C to 80° C (-31° F to 176° F) Type K (supplied) 0 to 200°C (32 to 392°F)

K type -200 to +1350°C / -328 to +2462°F

J type -200 à +1190°C / -328 à +2174°F

T Type -200 à +390°C / -328 à +734°F

Internal resolution  0.5 ° C (1 ° F)
Accuracy (overall error) ±1°C / ±2°F (data logger only – thermocouple error not included) 0.55 ° C (1.04 ° F) typical (5 à 60 ° C) ±1°C / ±2°F (data logger only – thermocouple error not included)
Long term stability <0.02 ° C (0.04 ° F) / year
Relative Humidity:
Measurement range 0 à 100% HR
Internal resolution 0,5% HR
Accuracy (overall error) 2.25% RH typical (20 to 80% RH)
Long term stability <0.25% RH / year
Logging Rate User selectable between 10 seconds and 12 hours User selectable between 10 seconds and 12 hours User selectable between 10 seconds and 12 hours
Battery Life 2 years 2 years 2 years
Readings 32 510 16 000 32 510

QUICK TIP:

BATTERY INFORMATION
Replacement

  • We recommend that you replace the battery annually, or prior to logging critical data. Only use 3.6V ½AA lithium metal batteries.
    The data logger does not lose its stored readings when the battery is discharged or replaced; however, the data logging process will
    stop and will not resume until the battery is replaced and the logger restarted by EL-WIN-USB or an EL-DataPad.
  • Before replacing the battery, remove the data logger from the PC. Please note that leaving the data logger plugged into the USB
    port for extended periods will cause some of the battery capacity to be lost.

Download Data Sheet
Download Instruction Manual