cGas Detector Digital Transmitter

Critical Environment Technologies - cGas

$590.00 CAD$890.00 CAD

One or two channel Modbus® or BACnet® gas detector with flexible customization options and Plug & Play Smart Sensor Technology

Support, maintenance, calibration –
1 800 463-4363
 

For monitoring: Ammonia, Carbon monoxide, Carbon dioxide, Chlorine, Ethylene, Ethylene oxide, Formaldehyde, Hydrogen, Hydrogen fluoride, Hydrogen sulphide, Nitric oxide, Nitrogen dioxide, Oxygen, Ozone, Sulfur dioxide, Ethanol, Dimethyl ether, Methanol, Methane, Propane, Hydrogen, TVOCs, Refrigerants

The cGas Detector is a digital, one or two channel gas detection transmitter that offers greater flexibility at a lower cost with customized sensor combinations and specialized options for adding only the functionality you need. It is ideal for monitoring toxic, combustible and refrigerant gases in commercial and light industrial, non-hazardous (non-explosion rated) environments.

Output is user selectable in the field with your choice of BACnet® or Modbus® for communicating with a Controller or a Building Automation System. Pre-calibrated sensors with true Plug & Play Smart Sensor technology makes replacing sensors quick and easy.

Powered by 24 VDC or ground reference AC, the digital cGas Detector it has an LCD display, temperature compensation, thermal resetting fuses and the firmware and configuration can be upgraded in the field using the USB connection. Specialized optional features include, relative humidity and temperature monitoring, low temperature operation, relay and wash-down / water spray protection.

The digital cGas Detector comes in a standard water / dust tight, corrosion resistant ABS / polycarbonate enclosure with a hinged, secured door. With the optional, factory installed standard splash guard the enclosure is IP54 rated and provides protection in water spray or wash down applications.

Models

CGAS-D-CO
Single channel, internal electrochemical carbon monoxide (CO) sensor (0 – 200 ppm range),LCD display, in field configurable Modbus RTU RS-485 or BACnet MS/TP RS-485 output, Plug & Play Smart sensor replacement

CGAS-D-CO-NO2
Dual channel, internal carbon monoxide (CO) sensor (0 – 200 ppm range) and nitrogen dioxide (NO2) sensor (0 – 10 ppm),LCD display, in field configurable Modbus RTU RS-485 or BACnet MS/TP RS-485 output, Plug & Play Smart sensor replacement

CGAS-D-SR404A
Single channel solid state refrigerant (R404A) sensor (0 – 2,000 ppm range),LCD display, in field configurable Modbus RTU RS-485 or BACnet MS/TP RS-485 output, Plug & Play Smart sensor replacement

CGAS-D-CO-R
Dual channel, internal carbon monoxide (CO) sensor (0 – 200 ppm range),must add ESH-A remote sensor, LCD display, in field configurable Modbus RTU RS-485 or BACnet MS/TP RS-485 output, Plug & Play Smart sensor replacement

CGAS-D-NO2
Single channel, internal electrochemical (NO2) sensor (0 – 10 ppm range),LCD display, in field configurable Modbus RTU RS-485 or BACnet MS/TP RS-485 output, Plug & Play Smart sensor replacement

Features

  • Up to 2 gas channel configurations
  • User in the field configurable BACnet® MS/TP RS-485 or Modbus® RTU RS-485 digital output signal
  • Easy Plug & Play Smart Sensor replacement at end of life, comes pre-calibrated
  • Bright LCD display
  • USB port for configuration changes and firmware upgrades
  • Internal 2A SPDT dry contact relay with or without internal buzzer (Option -RBZ or Option -RLY)
  • Optional RH & Temperature sensor (Option -RHT)
  • Optional low temperature operation package (Option -LT)
  • Optional factory installed splash guard (Option -S or Option -SN)
  • Standard black, ABS/polycarbonate, water / dust tight, corrosion resistant enclosure (drip proof),IP54 with optional splash guard installed
  • Sensor Calibrating Extending Firmware (CEF) for enclosed parking applications
  • RoHS compliant circuit boards

Specifications

Target Gas

Electrochemical Sensors Ammonia (NH3),Carbon monoxide (CO),Chlorine (CL2),Ethylene (C2H4),Ethylene oxide (C2H4O),Formaldehyde (CH2O),Hydrogen (H2),Hydrogen fluoride (HF),Hydrogen sulphide (H2S),Nitric oxide (NO),Nitrogen dioxide (NO2),Oxygen (O2),Ozone (O3),Silane (SiH4),Sulphur dioxide (SO2)
Infrared Sensor Carbon dioxide (CO2)
Solid State Sensors Refrigerants R22, R32, R134A, R402A, R404A, R407C, R410A, R422D, R438A, R448A, R449A, R507A, R513A, R514A, TVOCs
Catalytic Sensors Ammonia (NH3),Hydrogen (H2),Methane (CH4),Propane (C3H8),Ethanol or Dimethyl Ether (C2H6O),Methanol (CH4O)
PID Sensors TVOC

Mechanical

Enclosure Black ABS / Polycarbonate, corrosion resistant
Copper coated interior to reduce RF interference
IP54 rated with standard splash guard installed (Option -S)
Weight 400 g / 14 oz
Size 127 x 127 x 76 mm / 5.0 x 5.0 x 3.0 inches

User Interface

Display (standard) 2-line by 16 character graphic LCD
Operating Temp: 0°C to 40°C / 32°F to 104°F
Display (Option -LT) 2-line by 16 character OLED display for cold environment applications down to -40°C / -40°F
Push Buttons Initiate calibration and menu options with internal UP, DOWN and ENTER push buttons
USB Port Internal port for USB memory stick for field firmware / configuration upgrades

Input/Output

Communication User configurable in the field, BACnet® MS/TP (version 1 rev 14) RS-485 or Modbus® RTU (version 1.1b3) RS-485
RH & Temperature (Option -RHT) User selectable units DegC or DegF
Relay & Buzzer* 1 SPDT relay rated 30 volts, 2 amp max with internal buzzer rated 90 dB @ 10 cm / 4 in, enable/disable
Relay (Option -RLY) 1 SPDT relay rated 30 volts, 2 amp max

Electrical

Power Requirement 16-30 VDC, 3 W*, Class 2
*dependent on sensor type
12-27 VAC, 50-60 Hz, 3 VA*, Class 2
*dependent on sensor type
Wiring VDC or VAC (ground referenced) 4-conductor shielded 16 AWG stranded within conduit, network wiring (daisy-chain)
Fuse(s) Automatic resetting thermal

Environmental

Operating Temperature 0°C to 40°C (32°F to 104°F),temperatures below 0°C / 32°F require Option-LT
Operating Humidity 15 – 90% RH non-condensing

Certifications

Conforms to CSA-C22.2 No. 205-12, UL508 (Edition 18):2018
EMC Directive 2014/30/EU, EN 50270:2015, Type 1, EN61010
FCC. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Listed by BTL
RoHS compliant circuit boards
CO and NO2 Sensor Complies with UL2075, 2nd Edition, Standard for Gas and Vapour Detectors and Sensors

 

For monitoring: Ammonia, Carbon monoxide, Carbon dioxide, Chlorine, Ethylene, Ethylene oxide, Formaldehyde, Hydrogen, Hydrogen fluoride, Hydrogen sulphide, Nitric oxide, Nitrogen dioxide, Oxygen, Ozone, Sulfur dioxide, Ethanol, Dimethyl ether, Methanol, Methane, Propane, Hydrogen, TVOCs, Refrigerants

The cGas Detector is a digital, one or two channel gas detection transmitter that offers greater flexibility at a lower cost with customized sensor combinations and specialized options for adding only the functionality you need. It is ideal for monitoring toxic, combustible and refrigerant gases in commercial and light industrial, non-hazardous (non-explosion rated) environments.

Output is user selectable in the field with your choice of BACnet® or Modbus® for communicating with a Controller or a Building Automation System. Pre-calibrated sensors with true Plug & Play Smart Sensor technology makes replacing sensors quick and easy.

Powered by 24 VDC or ground reference AC, the digital cGas Detector it has an LCD display, temperature compensation, thermal resetting fuses and the firmware and configuration can be upgraded in the field using the USB connection. Specialized optional features include, relative humidity and temperature monitoring, low temperature operation, relay and wash-down / water spray protection.

The digital cGas Detector comes in a standard water / dust tight, corrosion resistant ABS / polycarbonate enclosure with a hinged, secured door. With the optional, factory installed standard splash guard the enclosure is IP54 rated and provides protection in water spray or wash down applications.

Models

CGAS-D-CO
Single channel, internal electrochemical carbon monoxide (CO) sensor (0 – 200 ppm range),LCD display, in field configurable Modbus RTU RS-485 or BACnet MS/TP RS-485 output, Plug & Play Smart sensor replacement

CGAS-D-CO-NO2
Dual channel, internal carbon monoxide (CO) sensor (0 – 200 ppm range) and nitrogen dioxide (NO2) sensor (0 – 10 ppm),LCD display, in field configurable Modbus RTU RS-485 or BACnet MS/TP RS-485 output, Plug & Play Smart sensor replacement

CGAS-D-SR404A
Single channel solid state refrigerant (R404A) sensor (0 – 2,000 ppm range),LCD display, in field configurable Modbus RTU RS-485 or BACnet MS/TP RS-485 output, Plug & Play Smart sensor replacement

CGAS-D-CO-R
Dual channel, internal carbon monoxide (CO) sensor (0 – 200 ppm range),must add ESH-A remote sensor, LCD display, in field configurable Modbus RTU RS-485 or BACnet MS/TP RS-485 output, Plug & Play Smart sensor replacement

CGAS-D-NO2
Single channel, internal electrochemical (NO2) sensor (0 – 10 ppm range),LCD display, in field configurable Modbus RTU RS-485 or BACnet MS/TP RS-485 output, Plug & Play Smart sensor replacement

Features

  • Up to 2 gas channel configurations
  • User in the field configurable BACnet® MS/TP RS-485 or Modbus® RTU RS-485 digital output signal
  • Easy Plug & Play Smart Sensor replacement at end of life, comes pre-calibrated
  • Bright LCD display
  • USB port for configuration changes and firmware upgrades
  • Internal 2A SPDT dry contact relay with or without internal buzzer (Option -RBZ or Option -RLY)
  • Optional RH & Temperature sensor (Option -RHT)
  • Optional low temperature operation package (Option -LT)
  • Optional factory installed splash guard (Option -S or Option -SN)
  • Standard black, ABS/polycarbonate, water / dust tight, corrosion resistant enclosure (drip proof),IP54 with optional splash guard installed
  • Sensor Calibrating Extending Firmware (CEF) for enclosed parking applications
  • RoHS compliant circuit boards

Specifications

Target Gas

Electrochemical Sensors Ammonia (NH3),Carbon monoxide (CO),Chlorine (CL2),Ethylene (C2H4),Ethylene oxide (C2H4O),Formaldehyde (CH2O),Hydrogen (H2),Hydrogen fluoride (HF),Hydrogen sulphide (H2S),Nitric oxide (NO),Nitrogen dioxide (NO2),Oxygen (O2),Ozone (O3),Silane (SiH4),Sulphur dioxide (SO2)
Infrared Sensor Carbon dioxide (CO2)
Solid State Sensors Refrigerants R22, R32, R134A, R402A, R404A, R407C, R410A, R422D, R438A, R448A, R449A, R507A, R513A, R514A, TVOCs
Catalytic Sensors Ammonia (NH3),Hydrogen (H2),Methane (CH4),Propane (C3H8),Ethanol or Dimethyl Ether (C2H6O),Methanol (CH4O)
PID Sensors TVOC

Mechanical

Enclosure Black ABS / Polycarbonate, corrosion resistant
Copper coated interior to reduce RF interference
IP54 rated with standard splash guard installed (Option -S)
Weight 400 g / 14 oz
Size 127 x 127 x 76 mm / 5.0 x 5.0 x 3.0 inches

User Interface

Display (standard) 2-line by 16 character graphic LCD
Operating Temp: 0°C to 40°C / 32°F to 104°F
Display (Option -LT) 2-line by 16 character OLED display for cold environment applications down to -40°C / -40°F
Push Buttons Initiate calibration and menu options with internal UP, DOWN and ENTER push buttons
USB Port Internal port for USB memory stick for field firmware / configuration upgrades

Input/Output

Communication User configurable in the field, BACnet® MS/TP (version 1 rev 14) RS-485 or Modbus® RTU (version 1.1b3) RS-485
RH & Temperature (Option -RHT) User selectable units DegC or DegF
Relay & Buzzer* 1 SPDT relay rated 30 volts, 2 amp max with internal buzzer rated 90 dB @ 10 cm / 4 in, enable/disable
Relay (Option -RLY) 1 SPDT relay rated 30 volts, 2 amp max

Electrical

Power Requirement 16-30 VDC, 3 W*, Class 2
*dependent on sensor type
12-27 VAC, 50-60 Hz, 3 VA*, Class 2
*dependent on sensor type
Wiring VDC or VAC (ground referenced) 4-conductor shielded 16 AWG stranded within conduit, network wiring (daisy-chain)
Fuse(s) Automatic resetting thermal

Environmental

Operating Temperature 0°C to 40°C (32°F to 104°F),temperatures below 0°C / 32°F require Option-LT
Operating Humidity 15 – 90% RH non-condensing

Certifications

Conforms to CSA-C22.2 No. 205-12, UL508 (Edition 18):2018
EMC Directive 2014/30/EU, EN 50270:2015, Type 1, EN61010
FCC. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Listed by BTL
RoHS compliant circuit boards
CO and NO2 Sensor Complies with UL2075, 2nd Edition, Standard for Gas and Vapour Detectors and Sensors