Bread and dough ph tester

Hanna - HI981038
Measure the pH during baking processes

$145.00 CAD

  • 12 Months Limited Warranty
  • 0.0 to 12.00 pH Range
  • Accuracy ±0.05 pH
  • Battery life ± 800 hours of continuous use
CLICK HERE TO ADD A CALIBRATION CERTIFICATE   $100.00 CAD

Support, maintenance, calibration
1 800 463-4363

 

The HI-981038 Bread and dough ph tester is designed to measure the pH during baking processes and ensure it meets the food-hygiene and Hazard Analysis Critical Control Point (HACCP) regulations.

The Bread and dough ph tester features a single button operating system and is easy to use. It has a compact and waterproof casing and automatic pH calibration at one or two points.
All readings are automatically compensated for temperature variations with a built-in temperature sensor.
The conical-shaped electrode is ideal to pierce solid and semisolid samples.
The open junction prevents samples from clogging the junction.
Probe Features Conical Tip – The conical tip allows for direct measurement in whey and semisolid samples.
Specialized Glass Formulation – Specialised low temperature (LT) pH glass ensures fast stabilization and accurate results at lower temperatures.

Open Junction Reference – The open junction design consists of a solid gel interface between the dough sample and internal Ag/AgCl reference. This interface prevents silver from entering the sample and makes it impermeable to clogging, resulting in a fast response and stable reading.

Polyvinylidene Fluoride (PVDF) Body – PVDF is a food-grade plastic that is resistant to most chemicals and solvents, including sodium hypochlorite, it is also resistant to fungal growth. It has high abrasion resistance, mechanical strength, and resistance to ultraviolet.

Hanna Instruments: new line of specialized pH testers

Supplied with:

  1. HI-70004 pH 4.01 buffer solution, 20 mL sachet (2)
  2. HI-70007 pH 7.01 buffer solution, 20 mL sachet (2 p)
  3. HI-700684 Electrode cleaning and disinfection solution for bread and dough deposits, 20 mL sachet (2 pcs.)
  4. HI-9072 Electrode storage solution, 13 mL dropper
  5. CR2032 3V Lithium-ion battery
  6. Instrument quality certificate
  7. Instruction manual

Accessories & refills

  1. pH Buffer Solution HI-70004P pH 4.01 buffer solution, 20 mL sachet (25 pcs.)
  2. HI-70007P pH 7.01 buffer solution, 20 mL sachet (25 pcs.)
  3. HI-77400P pH 4.01 & 7.01 buffer solution, 20 mL sachet (10 pcs., 5 each)

Electrode Cleaning Solution

  1. HI-700601P General purpose cleaning solution, 20 mL sachet (25 pcs.)
  2. HI-700684P Electrode cleaning and disinfection solution for bread and dough deposits, 20 mL sachet (25pcs.)

Electrode Storage Solution

  1. HI-70300L Electrode storage solution, 500 mL
  2. HI-70300M Electrode storage solution, 230 mL
  3. HI-9072 Electrode storage solution, 13 mL dropper

Specifications

Specifications Range 0.0 to 12.00 pH
Resolution 0.01pH
Accuracy ±0.05 pH
Calibration Automatic, one or two-point Temperature compensation Automatic, 0 to 50 °C
Electrode Built-in probe for specific application
Battery type CR2032 Lithium-ion (included)
Battery life Approximately 800 hours of continuous use
Auto-off 8 minutes, 60 minutes or disabled. Environment 0 to 50 °C (32 to 122 °F); RH 95% max
Dimensions 50 x 129 x 21 mm (2 x 5.1 x 0.9“)
Weight 42 g (1.48 oz.)

QUICK TIP:

PREPARATION:

• Remove the protective cap. Do not be concerned if salt deposits are present. Rinse the probe with water and wipe it dry.
• If the glass and/or junction is dry, soak the electrode (4 cm) in a storage solution for at least 30 minutes. Rinse with water and blot dry.
• Calibrate the electrode before use. For best results, it is recommended to recalibrate periodically.

Other models available:

pH Tester for Beer

CHEESE PH TESTER

PH TESTER FOR FOOD (MEAT)

 

 

 

 

The HI-981038 Bread and dough ph tester is designed to measure the pH during baking processes and ensure it meets the food-hygiene and Hazard Analysis Critical Control Point (HACCP) regulations.

The Bread and dough ph tester features a single button operating system and is easy to use. It has a compact and waterproof casing and automatic pH calibration at one or two points.
All readings are automatically compensated for temperature variations with a built-in temperature sensor.
The conical-shaped electrode is ideal to pierce solid and semisolid samples.
The open junction prevents samples from clogging the junction.
Probe Features Conical Tip – The conical tip allows for direct measurement in whey and semisolid samples.
Specialized Glass Formulation – Specialised low temperature (LT) pH glass ensures fast stabilization and accurate results at lower temperatures.

Open Junction Reference – The open junction design consists of a solid gel interface between the dough sample and internal Ag/AgCl reference. This interface prevents silver from entering the sample and makes it impermeable to clogging, resulting in a fast response and stable reading.

Polyvinylidene Fluoride (PVDF) Body – PVDF is a food-grade plastic that is resistant to most chemicals and solvents, including sodium hypochlorite, it is also resistant to fungal growth. It has high abrasion resistance, mechanical strength, and resistance to ultraviolet.

Hanna Instruments: new line of specialized pH testers

Supplied with:

  1. HI-70004 pH 4.01 buffer solution, 20 mL sachet (2)
  2. HI-70007 pH 7.01 buffer solution, 20 mL sachet (2 p)
  3. HI-700684 Electrode cleaning and disinfection solution for bread and dough deposits, 20 mL sachet (2 pcs.)
  4. HI-9072 Electrode storage solution, 13 mL dropper
  5. CR2032 3V Lithium-ion battery
  6. Instrument quality certificate
  7. Instruction manual

Accessories & refills

  1. pH Buffer Solution HI-70004P pH 4.01 buffer solution, 20 mL sachet (25 pcs.)
  2. HI-70007P pH 7.01 buffer solution, 20 mL sachet (25 pcs.)
  3. HI-77400P pH 4.01 & 7.01 buffer solution, 20 mL sachet (10 pcs., 5 each)

Electrode Cleaning Solution

  1. HI-700601P General purpose cleaning solution, 20 mL sachet (25 pcs.)
  2. HI-700684P Electrode cleaning and disinfection solution for bread and dough deposits, 20 mL sachet (25pcs.)

Electrode Storage Solution

  1. HI-70300L Electrode storage solution, 500 mL
  2. HI-70300M Electrode storage solution, 230 mL
  3. HI-9072 Electrode storage solution, 13 mL dropper

Specifications

Specifications Range 0.0 to 12.00 pH
Resolution 0.01pH
Accuracy ±0.05 pH
Calibration Automatic, one or two-point Temperature compensation Automatic, 0 to 50 °C
Electrode Built-in probe for specific application
Battery type CR2032 Lithium-ion (included)
Battery life Approximately 800 hours of continuous use
Auto-off 8 minutes, 60 minutes or disabled. Environment 0 to 50 °C (32 to 122 °F); RH 95% max
Dimensions 50 x 129 x 21 mm (2 x 5.1 x 0.9“)
Weight 42 g (1.48 oz.)

QUICK TIP:

PREPARATION:

• Remove the protective cap. Do not be concerned if salt deposits are present. Rinse the probe with water and wipe it dry.
• If the glass and/or junction is dry, soak the electrode (4 cm) in a storage solution for at least 30 minutes. Rinse with water and blot dry.
• Calibrate the electrode before use. For best results, it is recommended to recalibrate periodically.

Other models available:

pH Tester for Beer

CHEESE PH TESTER

PH TESTER FOR FOOD (MEAT)