Indoor Air Quality Monitor, 8 Channel

Critical Environment Technologies- YESAIR/YESAIR-A+
Ideal for intermittent or continuous indoor air quality monitoring

$2,135.00 CAD$2,885.00 CAD

  • 8 sensor capacity
  • Light weight, contoured & comfortable handheld device
  • LCD displays all sensors

Support, maintenance, calibration
1 800 463-4363

 

Need intermittent or continuous indoor air quality monitoring? YESAIR-A+ is designed for it

Pump / diffusion air quality monitoring

It is available in two models (Pump or Diffusion). Each can be configured as a multi-channel operation, with a selection of more than 30 different plug and play gas sensors, including a particulate sensor and an optional huge capacity data logging SD memory card. Both models come with one temperature sensor, one relative humidity (RH) sensor, the capacity for 5 internal gas sensors consisting of a maximum of three electrochemical toxic gas or oxygen sensors plus two high current draw sensors such as an infrared, PID, catalytic or particulate sensor.

Sensor readings, battery level and data logging status can be viewed live on the multi-line, back-lit, LCD display. The optional YES Viewer Logger package offers a 2 GB SD memory card with card reader, a USB cable and YES Viewer software. The card reader can be used to store or transfer data. Alternatively, data can be downloaded to a computer using the mini USB connection.

The YES Viewer software allows users to analyze and graph data. An optional sampling probe is available with the Pump model. The probe has a 10 inch wand and 30 inches of tubing that fits onto the nozzle and allows you to reach into areas that are difficult to access.

KEY FEATURES

  • 8 sensor capacity
  • > 30 plug & play sensors available to choose from, including electrochemical, catalytic, infrared & PID
  • Multi-function, easy to use menu
  • Light weight, contoured & comfortable handheld device
  • LCD displays all sensors
  • Sampling with internal sample draw pump or by diffusion
  • High capacity data logging with built-in SD flash card
  • Data logging software available
  • RoHS compliant circuit boards
  • CE certified

TECHNICAL SPECIFICATIONS

MECHANICAL
Enclosure Rugged ABS / Polycarbonate (UL94 rated)
Weight 567 g (20 oz)
Size 7.8” x 3.1” x 3.9” (197 mm x 78 mm x 98 mm)
ELECTRICAL
Power Standard: Rechargable 3.6 V NiMH battery
pack (8 hours continuous operation time
c/w plug-in battery charger / wall adapter
(100 – 240 V, 50 – 60 Hz)
Optional: Alkaline AA batteries x 3
Sampling Standard: Internal, automatic sample pump
for “active” sampling of target environment
Optional: Diffusion for quick, direct reading.
Memory > 1 million data points data logging to SD flash card
(optional)
Calibration Automated through keypad
Information Record 12 bit, multi-channel, user configurable
with removable flash card 2 GB.
YES Logger package option includes 2 GB SD
flash card, USB cable, YES Viewer software,
and SD flash card reader.
Communication Miniature USB port for changing settings
and configuring logging functions and
auxiliary port for using additional sensors
(i.e. YESDUST)
Audible Internal 80 Db @ 4’. One set point
adjustment. Audible can be switched off
through menu
ENVIRONNEMENTAl (sensor dependant)
Operating Temperature 5°C to 50°C (41°F to 122°F
Humidity 0 – 99% RH non-condensing
CERTIFICATION
CE Certified CE standards for safety:
I .S. EN61010-1:2001 (Ed.2)
CE standards for emissions: EN 50270:2006
CE standards for immunity: EN 50270:2006

 

PRODUCT CODES

Temperature & RH sensors, internal pump,
rechargeable batteries (3 x AA NiMH),
battery charger, capacity for 5 gas sensors
YESAIR
Temperature & RH sensors, diffuser cap, rechargeable batteries (3 x AA NiMH),battery charger, capacity for 5 gas sensors YESAIR-D
OPTIONS
Ammonia (NH 3) electrochemical, 0 – 50 ppm PNP-H
Arsine (AsH 3) electrochemical, 0 – 2 ppm PNP-R
Carbon dioxide (CO2) infrared, 0 – 5,000 ppm PNP-A+
Carbon dioxide (CO2) infrared, 0 – 10,000 ppm PNP-A1
Carbon dioxide (CO2) infrared, 0 – 20% volume PNP-A2
Carbon dioxide (CO2) infrared, 0 – 5% volume PNP-B
Carbon dioxide (CO2) infrared, 0 – 100% volume PNP-B1
Carbon monoxide (CO) electrochemical, 0 – 50 ppm PNP-C
Carbon monoxide (CO) electrochemical, 0 – 50 ppm
(H2 compensated for use in H2 background)
PNP-C1
Chlorine (Cl2) electrochemical, 0 – 5 ppm PNP-I
Chlorine dioxide (ClO2),electrochemical, 0 – 1 ppm PNP-J
Combustibles (catalytic),0 – 100% LEL PNP-X
Ethylene (C2H4),0 – 500 ppm PNP-E1
Ethylene oxide (C2H4O),0 – 20 ppm PNP-E2
Fluorine (F2) electrochemical, 0 – 2 ppm PNP-S
Formaldehyde (CH2O) electrochemical, 0 – 10 ppm PNP-Q
Hydrogen (H2) electrochemical, 0 – 1,000 ppm PNP-K
Hydrogen chloride (HCl) electrochemical, 0 – 30 ppm PNP-M
Hydrogen cyanide (HCN) electrochemical, 0 – 100 ppm PNP-N
Hydrogen fluoride (HF) electrochemical, 0 – 10 ppm PNP-O
Hydrogen sulphide (H2S) electrochemical, 0 – 50 ppm PNP-L
Nitric oxide (NO) electrochemical, 0 – 100 ppm PNP-E
Nitrogen dioxide (NO2) electrochemical, 0 – 5 ppm PNP-D
Oxygen (O2) electrochemical, 0 – 25% volume PNP-F
Ozone (O3) electrochemical, 0 – 1 ppm PNP-G
Phosphine (PH3) electrochemical, 0 – 1 ppm PNP-V
Silane (SiH4) electrochemical, 0 – 1 ppm PNP-W
Sulphur dioxide (SO2) electrochemical, 0 – 20 ppm PNP-P
TVOCs (PID),0 – 300 ppm PNP-Y+
TVOCs (PID),0 – 50 ppm PNP-Z+
External mounted nickel metal hydride pack YESAIR BATT OPTION

 

ACCESSORIES

YES logger package, 2 GB flash card, USB cable, YES
Viewer software, SD flash card reader
YESAIR-LGRPKG
Handheld probe 10” with 30” of sample hose YES-HHPROBE-10
YES Viewer information logging software CD YES-SFTWRE

 

Need intermittent or continuous indoor air quality monitoring? YESAIR-A+ is designed for it

Pump / diffusion air quality monitoring

It is available in two models (Pump or Diffusion). Each can be configured as a multi-channel operation, with a selection of more than 30 different plug and play gas sensors, including a particulate sensor and an optional huge capacity data logging SD memory card. Both models come with one temperature sensor, one relative humidity (RH) sensor, the capacity for 5 internal gas sensors consisting of a maximum of three electrochemical toxic gas or oxygen sensors plus two high current draw sensors such as an infrared, PID, catalytic or particulate sensor.

Sensor readings, battery level and data logging status can be viewed live on the multi-line, back-lit, LCD display. The optional YES Viewer Logger package offers a 2 GB SD memory card with card reader, a USB cable and YES Viewer software. The card reader can be used to store or transfer data. Alternatively, data can be downloaded to a computer using the mini USB connection.

The YES Viewer software allows users to analyze and graph data. An optional sampling probe is available with the Pump model. The probe has a 10 inch wand and 30 inches of tubing that fits onto the nozzle and allows you to reach into areas that are difficult to access.

KEY FEATURES

  • 8 sensor capacity
  • > 30 plug & play sensors available to choose from, including electrochemical, catalytic, infrared & PID
  • Multi-function, easy to use menu
  • Light weight, contoured & comfortable handheld device
  • LCD displays all sensors
  • Sampling with internal sample draw pump or by diffusion
  • High capacity data logging with built-in SD flash card
  • Data logging software available
  • RoHS compliant circuit boards
  • CE certified

TECHNICAL SPECIFICATIONS

MECHANICAL
Enclosure Rugged ABS / Polycarbonate (UL94 rated)
Weight 567 g (20 oz)
Size 7.8” x 3.1” x 3.9” (197 mm x 78 mm x 98 mm)
ELECTRICAL
Power Standard: Rechargable 3.6 V NiMH battery
pack (8 hours continuous operation time
c/w plug-in battery charger / wall adapter
(100 – 240 V, 50 – 60 Hz)
Optional: Alkaline AA batteries x 3
Sampling Standard: Internal, automatic sample pump
for “active” sampling of target environment
Optional: Diffusion for quick, direct reading.
Memory > 1 million data points data logging to SD flash card
(optional)
Calibration Automated through keypad
Information Record 12 bit, multi-channel, user configurable
with removable flash card 2 GB.
YES Logger package option includes 2 GB SD
flash card, USB cable, YES Viewer software,
and SD flash card reader.
Communication Miniature USB port for changing settings
and configuring logging functions and
auxiliary port for using additional sensors
(i.e. YESDUST)
Audible Internal 80 Db @ 4’. One set point
adjustment. Audible can be switched off
through menu
ENVIRONNEMENTAl (sensor dependant)
Operating Temperature 5°C to 50°C (41°F to 122°F
Humidity 0 – 99% RH non-condensing
CERTIFICATION
CE Certified CE standards for safety:
I .S. EN61010-1:2001 (Ed.2)
CE standards for emissions: EN 50270:2006
CE standards for immunity: EN 50270:2006

 

PRODUCT CODES

Temperature & RH sensors, internal pump,
rechargeable batteries (3 x AA NiMH),
battery charger, capacity for 5 gas sensors
YESAIR
Temperature & RH sensors, diffuser cap, rechargeable batteries (3 x AA NiMH),battery charger, capacity for 5 gas sensors YESAIR-D
OPTIONS
Ammonia (NH 3) electrochemical, 0 – 50 ppm PNP-H
Arsine (AsH 3) electrochemical, 0 – 2 ppm PNP-R
Carbon dioxide (CO2) infrared, 0 – 5,000 ppm PNP-A+
Carbon dioxide (CO2) infrared, 0 – 10,000 ppm PNP-A1
Carbon dioxide (CO2) infrared, 0 – 20% volume PNP-A2
Carbon dioxide (CO2) infrared, 0 – 5% volume PNP-B
Carbon dioxide (CO2) infrared, 0 – 100% volume PNP-B1
Carbon monoxide (CO) electrochemical, 0 – 50 ppm PNP-C
Carbon monoxide (CO) electrochemical, 0 – 50 ppm
(H2 compensated for use in H2 background)
PNP-C1
Chlorine (Cl2) electrochemical, 0 – 5 ppm PNP-I
Chlorine dioxide (ClO2),electrochemical, 0 – 1 ppm PNP-J
Combustibles (catalytic),0 – 100% LEL PNP-X
Ethylene (C2H4),0 – 500 ppm PNP-E1
Ethylene oxide (C2H4O),0 – 20 ppm PNP-E2
Fluorine (F2) electrochemical, 0 – 2 ppm PNP-S
Formaldehyde (CH2O) electrochemical, 0 – 10 ppm PNP-Q
Hydrogen (H2) electrochemical, 0 – 1,000 ppm PNP-K
Hydrogen chloride (HCl) electrochemical, 0 – 30 ppm PNP-M
Hydrogen cyanide (HCN) electrochemical, 0 – 100 ppm PNP-N
Hydrogen fluoride (HF) electrochemical, 0 – 10 ppm PNP-O
Hydrogen sulphide (H2S) electrochemical, 0 – 50 ppm PNP-L
Nitric oxide (NO) electrochemical, 0 – 100 ppm PNP-E
Nitrogen dioxide (NO2) electrochemical, 0 – 5 ppm PNP-D
Oxygen (O2) electrochemical, 0 – 25% volume PNP-F
Ozone (O3) electrochemical, 0 – 1 ppm PNP-G
Phosphine (PH3) electrochemical, 0 – 1 ppm PNP-V
Silane (SiH4) electrochemical, 0 – 1 ppm PNP-W
Sulphur dioxide (SO2) electrochemical, 0 – 20 ppm PNP-P
TVOCs (PID),0 – 300 ppm PNP-Y+
TVOCs (PID),0 – 50 ppm PNP-Z+
External mounted nickel metal hydride pack YESAIR BATT OPTION

 

ACCESSORIES

YES logger package, 2 GB flash card, USB cable, YES
Viewer software, SD flash card reader
YESAIR-LGRPKG
Handheld probe 10” with 30” of sample hose YES-HHPROBE-10
YES Viewer information logging software CD YES-SFTWRE