The Portable Oximeter is one of Milwaukee’s most popular meters with its reliable and fast operation as well as its 0.0 to 45.00 Mg/l (ppm) accuracy.
The Portable Oximeter Milwaukee MW605 MAX DO Meter is preferred by people looking for lab-level accuracy without the cost. The Milwaukee DO Meter is popular with everyone from field biologists, educators, fish farmers, koi pond owners, water treatment plants and labs.
DESIGN FEATURES
- Fast, easy-to-read results with large digital LCD readout.
- Galvanic probe means no conditioning time.
- Repeatable, accuracy to ±1.5% of reading.
- Water Proof IP 67 Rated.
- Lightweight and portable.
- Simple 1 or 2 % saturation calibration points at 100% (water-saturated air) and 0% (zero oxygen solution).
- Dedicated GLP key to store and recall data on system status.
- Available log space for up to 1000 records.
- Logged data export via USB cable.
- Altitude and Salinity compensation.
- Automatic temperature compensation °F & °C.
- Uses MA860 (included) reinforced Galvanic probe with an oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor.
- 2 O-rings, membranes and one protective cap included.
- 10 feet probe cable for extra flexibility when testing.
- 3 x 1.5 volt akaline AA battery (battery included) aprox. 200 hours of battery life with continuous use with low battery warning.
CARE AND MAINTENANCE
PROBE MAINTENANCE:
- The silver cathode should always be bright and untarnished. If it is tarnished or stained, the cathode should be cleaned gently with a lint-free cloth.
- Rinse the probe with deionized or distilled water.
- Replace the membrane cap using fresh electrolytes.
- Recalibrate meter.
Membrane Maintenance:
- For accurate and stable measurements, the perfect condition of the membrane surface is needed. Protect the thin membrane from scratches, abrasion or contact with solids.
- If no measurements are taken for a few hours, protect the membrane with the plastic protective cap.
- If fouled, rinse it carefully with distilled or deionized water. If damaged, replace the membrane cap.
Note: Change the membrane every 8 weeks or more frequently if used in a specially fouling environment. Check and replace the electrolyte fill solution every 4 weeks.
SPECIFICATIONS
- O2 Range*: 0.0 to 45.00 mg/L (ppm)
- O2 Range: 0.0 to 300.0 % Saturation
- Range Temperature**: -20.0 to 120.0 °C (-4.0 to 248.0 °F)
- O2Resolution: 0.01 mg/L (ppm) / 0.1 % Saturation
- Temperature Resolution: 0.1 °C (0.1 °F)
- O2 Accuracy: ±1.5% of reading ± 1 digit
- Temperature Accuracy: ± 0.4°C (±0.8°F)
- Calibration: One or Two % saturation calibration points 0 % (MA9070) and 100 % (water saturated air)
- Temperature Compensation: Automatic, from 0.0 to 50.0°C (32.0 to 122.0 °F)
- Altitude compensation: -500 to 4,000 m (-1,640′ to 13,123′) with 100 m (328′) resolution
- Salinity Compensation: Manual, from 0 to 40 g/L ( with 1 g/L resolution)
- Logging/Memory: Max. 1,000 log records (stored in up to 100 lots) / On Demand, 200 logs / On Stability, 200 logs / Interval logging, 1,000 logs
- PC Connectivity: 1 micro USB port
- Battery Type: 3 x 1.5V alkaline AA (included)
- Battery Life: Approx. 200 hours of use
- Environment: 0 to 50°C / 32 to 122°F; max RH 95%
- Dimensions Meter: 8 x 3.3 x 2.0 inches (200 x 85 x 50 mm)
- Dimensions Packaging: 14 x 12 x 6.0 inches (355.6 x 304.8 x 152.4 mm)
- Weight Meter: 0.57 lbs (260 g)
- Weight Packaged: 5.0 lbs (2.27 kg)
- Probe: MA860 Galvanic Probe included, 10′ (3 meters)
- Temperature Range: 0.0 to 50.0°C / 32.0 to 122.0°F
- Temperature Sensor: Built in Thermistor
- Cathode: Silver
- Anode: Zinc
- Membranes: Oxygen permeable PTFE (2) included
- Connector Socket: DIN 7pins
- Body: PP, ABS, IP67 rating
- Cable: Jacket material: PP
* Do measurement is performed within automatic temperature compensation interval.
** Limits will be reduced to actual sensor limits.
Storage:
After taking measurements, switch the meter off and clean the probe before storage. When not in use the probe should be stored with the plastic cap on.
For short-term storage, the probe can also be stored in a beaker of deionized water with the protective plastic cap removed.
For long-term storage, the probe should be stored dry:
1. Disconnect the probe from the meter.
2. Unscrew the membrane cap.
3. Remove any electrolyte solution from the cap.
4. Rinse the probe anode/cathode assembly with distilled water and blot dry.
5. Screw the membrane cap onto the probe until the membrane cap is hand-tight.
The Portable Oximeter is one of Milwaukee’s most popular meters with its reliable and fast operation as well as its 0.0 to 45.00 Mg/l (ppm) accuracy.
The Portable Oximeter Milwaukee MW605 MAX DO Meter is preferred by people looking for lab-level accuracy without the cost. The Milwaukee DO Meter is popular with everyone from field biologists, educators, fish farmers, koi pond owners, water treatment plants and labs.
DESIGN FEATURES
- Fast, easy-to-read results with large digital LCD readout.
- Galvanic probe means no conditioning time.
- Repeatable, accuracy to ±1.5% of reading.
- Water Proof IP 67 Rated.
- Lightweight and portable.
- Simple 1 or 2 % saturation calibration points at 100% (water-saturated air) and 0% (zero oxygen solution).
- Dedicated GLP key to store and recall data on system status.
- Available log space for up to 1000 records.
- Logged data export via USB cable.
- Altitude and Salinity compensation.
- Automatic temperature compensation °F & °C.
- Uses MA860 (included) reinforced Galvanic probe with an oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor.
- 2 O-rings, membranes and one protective cap included.
- 10 feet probe cable for extra flexibility when testing.
- 3 x 1.5 volt akaline AA battery (battery included) aprox. 200 hours of battery life with continuous use with low battery warning.
CARE AND MAINTENANCE
PROBE MAINTENANCE:
- The silver cathode should always be bright and untarnished. If it is tarnished or stained, the cathode should be cleaned gently with a lint-free cloth.
- Rinse the probe with deionized or distilled water.
- Replace the membrane cap using fresh electrolytes.
- Recalibrate meter.
Membrane Maintenance:
- For accurate and stable measurements, the perfect condition of the membrane surface is needed. Protect the thin membrane from scratches, abrasion or contact with solids.
- If no measurements are taken for a few hours, protect the membrane with the plastic protective cap.
- If fouled, rinse it carefully with distilled or deionized water. If damaged, replace the membrane cap.
Note: Change the membrane every 8 weeks or more frequently if used in a specially fouling environment. Check and replace the electrolyte fill solution every 4 weeks.
SPECIFICATIONS
- O2 Range*: 0.0 to 45.00 mg/L (ppm)
- O2 Range: 0.0 to 300.0 % Saturation
- Range Temperature**: -20.0 to 120.0 °C (-4.0 to 248.0 °F)
- O2Resolution: 0.01 mg/L (ppm) / 0.1 % Saturation
- Temperature Resolution: 0.1 °C (0.1 °F)
- O2 Accuracy: ±1.5% of reading ± 1 digit
- Temperature Accuracy: ± 0.4°C (±0.8°F)
- Calibration: One or Two % saturation calibration points 0 % (MA9070) and 100 % (water saturated air)
- Temperature Compensation: Automatic, from 0.0 to 50.0°C (32.0 to 122.0 °F)
- Altitude compensation: -500 to 4,000 m (-1,640′ to 13,123′) with 100 m (328′) resolution
- Salinity Compensation: Manual, from 0 to 40 g/L ( with 1 g/L resolution)
- Logging/Memory: Max. 1,000 log records (stored in up to 100 lots) / On Demand, 200 logs / On Stability, 200 logs / Interval logging, 1,000 logs
- PC Connectivity: 1 micro USB port
- Battery Type: 3 x 1.5V alkaline AA (included)
- Battery Life: Approx. 200 hours of use
- Environment: 0 to 50°C / 32 to 122°F; max RH 95%
- Dimensions Meter: 8 x 3.3 x 2.0 inches (200 x 85 x 50 mm)
- Dimensions Packaging: 14 x 12 x 6.0 inches (355.6 x 304.8 x 152.4 mm)
- Weight Meter: 0.57 lbs (260 g)
- Weight Packaged: 5.0 lbs (2.27 kg)
- Probe: MA860 Galvanic Probe included, 10′ (3 meters)
- Temperature Range: 0.0 to 50.0°C / 32.0 to 122.0°F
- Temperature Sensor: Built in Thermistor
- Cathode: Silver
- Anode: Zinc
- Membranes: Oxygen permeable PTFE (2) included
- Connector Socket: DIN 7pins
- Body: PP, ABS, IP67 rating
- Cable: Jacket material: PP
* Do measurement is performed within automatic temperature compensation interval.
** Limits will be reduced to actual sensor limits.
Storage:
After taking measurements, switch the meter off and clean the probe before storage. When not in use the probe should be stored with the plastic cap on.
For short-term storage, the probe can also be stored in a beaker of deionized water with the protective plastic cap removed.
For long-term storage, the probe should be stored dry:
1. Disconnect the probe from the meter.
2. Unscrew the membrane cap.
3. Remove any electrolyte solution from the cap.
4. Rinse the probe anode/cathode assembly with distilled water and blot dry.
5. Screw the membrane cap onto the probe until the membrane cap is hand-tight.