Tramex concrete determinator

Tramex - CDK
in-situ Moisture Content readings

$1,301.50 CAD

  • 12 months limited warranty
  • Determine if moisture is coming from below or above the concrete slab surface
  • Determine the type and extent of mitigation if needed
  • Reusable, Extendable, and requires no plastic hole liners

Support, maintenance, calibration
1 800 463-4363

 

The Tramex concrete determinator provides in-situ moisture content readings in a Tramex unified moisture content test method.

The Tramex Concrete Moisture Probe,  The Determinator, extends the capabilities of the Tramex Concrete Moisture Encounter range, the CME5, CMEX5 and older meters CME4 and CMEX2, providing in-situ Moisture Content readings in a Tramex Unified Moisture Content Test Method of quantitative Moisture Content measurements in both the top ¾ inch layer and within the  body of concrete floors and slabs down to an extendable depth of up to 4″ (100mm),Diameter 3/4” (19mm).

The Determinator is supplied in a Tramex hard case with allocated space for your Tramex Concrete Moisture meter.

Features

  • Instant and Accurate
  • Designed to work in the same drill-hole made for the F2170 test
  • Eliminate confusion between in-situ Relative Humidity tests and surface Moisture Content tests
  • Determine if moisture is coming from below or above the concrete slab surface
  • Determine the type and extent of mitigation if needed
  • Reusable, Extendable, and requires no plastic hole liners
  • Can be used in conjunction with Tramex Concrete Moisture Encounters CME5, CMEX5, (CME4 and CMEX2)

Product Design

The Concrete Moisture Probe when used with Tramex CME instruments operates on the principle that the electrical impedance of a material varies with its moisture content. The CME instrument is pressed onto the CMP cradle which is pressed onto the material surface with the pins fully compressed and the probe inserted into the pre-drilled 3/4″ (19mm) hole to measure the moisture content.

The electrical impedance is measured by creating a low frequency alternating electric field between the electrodes and the probe, to a depth of up to 4” (10cm). This field penetrates the material under test. The very small alternating current flowing through the field is inversely proportional to the impedance of the material. The instrument detects this current, determines its amplitude and thus derives the moisture value.

Operating Procedure

The Determinator cradle should be flat on the slab surface and the Tramex Concrete Moisture Meter placed and firmly pressed onto the cradle with the pins fully compressed.  The probe reads from the bottom, within the body of the slab, up to the surface.

Size: 17.1” x 14.2” x 5.5” (43.5cm x 36cm x 14cm)
Weight: 5.7 lbs (2.6kg)
Construction: ABS Body

CONCRETE MOISTURE PROBE ‘THE DETERMINATOR’ – MEASURING RANGE:

Moisture Content for Concrete with Tramex CMEX5 and CMEX2: 0 – 6.9%
Moisture Content for Concrete with Tramex CME5 and CME4: 0 – 6%
Depth of Penetration: 1 1/4” probe depth for concrete between 2” to 4”
2 1/4” probe depth for concrete between 4” to 6”
3 1/4” probe depth for concrete between 6” to 9”
4 1/4” probe depth for concrete between 9” to 11”

 


The Tramex concrete determinator provides in-situ moisture content readings in a Tramex unified moisture content test method.

The Tramex Concrete Moisture Probe,  The Determinator, extends the capabilities of the Tramex Concrete Moisture Encounter range, the CME5, CMEX5 and older meters CME4 and CMEX2, providing in-situ Moisture Content readings in a Tramex Unified Moisture Content Test Method of quantitative Moisture Content measurements in both the top ¾ inch layer and within the  body of concrete floors and slabs down to an extendable depth of up to 4″ (100mm),Diameter 3/4” (19mm).

The Determinator is supplied in a Tramex hard case with allocated space for your Tramex Concrete Moisture meter.

Features

  • Instant and Accurate
  • Designed to work in the same drill-hole made for the F2170 test
  • Eliminate confusion between in-situ Relative Humidity tests and surface Moisture Content tests
  • Determine if moisture is coming from below or above the concrete slab surface
  • Determine the type and extent of mitigation if needed
  • Reusable, Extendable, and requires no plastic hole liners
  • Can be used in conjunction with Tramex Concrete Moisture Encounters CME5, CMEX5, (CME4 and CMEX2)

Product Design

The Concrete Moisture Probe when used with Tramex CME instruments operates on the principle that the electrical impedance of a material varies with its moisture content. The CME instrument is pressed onto the CMP cradle which is pressed onto the material surface with the pins fully compressed and the probe inserted into the pre-drilled 3/4″ (19mm) hole to measure the moisture content.

The electrical impedance is measured by creating a low frequency alternating electric field between the electrodes and the probe, to a depth of up to 4” (10cm). This field penetrates the material under test. The very small alternating current flowing through the field is inversely proportional to the impedance of the material. The instrument detects this current, determines its amplitude and thus derives the moisture value.

Operating Procedure

The Determinator cradle should be flat on the slab surface and the Tramex Concrete Moisture Meter placed and firmly pressed onto the cradle with the pins fully compressed.  The probe reads from the bottom, within the body of the slab, up to the surface.

Size: 17.1” x 14.2” x 5.5” (43.5cm x 36cm x 14cm)
Weight: 5.7 lbs (2.6kg)
Construction: ABS Body

CONCRETE MOISTURE PROBE ‘THE DETERMINATOR’ – MEASURING RANGE:

Moisture Content for Concrete with Tramex CMEX5 and CMEX2: 0 – 6.9%
Moisture Content for Concrete with Tramex CME5 and CME4: 0 – 6%
Depth of Penetration: 1 1/4” probe depth for concrete between 2” to 4”
2 1/4” probe depth for concrete between 4” to 6”
3 1/4” probe depth for concrete between 6” to 9”
4 1/4” probe depth for concrete between 9” to 11”