What is the most accurate hygrometer/thermometer / psychrometer? It depends on multiple criteria. In this case, the unit provides the highest RH accuracy (2%) with 30 seconds response time.

Hygrometer-laboratory-geneq-2021Ideal for laboratory, industrial, wine cellar, engineering, and other professional uses, it is a high-end and professional instrument.

Combines the functions of a humidity meter, temperature meter, wet bulb thermometer, and dew point thermometer. 

A dual-illuminated readout can display wet bulb & humidity,  dew point & humidity, or temperature & humidity. Temperatures from -22 degrees to 199 degrees F (-30 degrees to 100 degrees C) and the full spectrum of relative humidity with ±2% accuracy between 20 and 90% RH. Complete with carrying case and 9V battery.

As a professional precision hygrometer, this unit meets strict quality criteria:

  • Fast Response Time %RH: 10S (90% at 25ºC still air)
  • High accuracy
  • Dew Point Temperature
  • Wet Bulb Temperature
  • Resolution 0.01%RH, 0.01ºC/0.01°F
  • Max Hold and Data Hold Function
  • Micro Processor-based Design
  • Dual Display Temperature & Humidity
  • Auto Power Off, Disable Sleep Mode
  • Backlight Display
  • Small Size
  • Slim design with rubberized sides for better grip and one-hand operation

One of the best hygrometers, now available in Canada

Display Large 4-1/2 dual digital LCD display with backlight
Sensor Type
A single-chip relative humidity and temperature multi-sensor module comprising a calibrated digital output.
Response Time %RH: 10S (90% at +25°C still air)
Accuracy Note Accuracy is specified for the following ambient temperature range: 64 to 82°F (18 to 28°C)
Sampling Rate 2.5 samples per second
Polarity Automatic, (-)negative polarity indication
Over-range “OL” mark indication
Low Battery Indication The “ ” is displayed when the battery voltage drops below the operating level.
Operating Conditions 32 to 104°F (0 to 40°C); < 80% RH non-condensing
Storage Conditions 14 to 140°F (-10 to 60°C); <80% RH non-condensing
Auto Power Off Meter automatically shuts down after approx.15 minutes of inactivity (Sleep Mode)
Power
Disable Option
One standard 9V, NEDA1604 or 6F22 battery
Dimensions/Wt. 225 (H) x 45 (W) x 34 (D) mm/200g
Humidity / Temperature Measurement Range
Humidity 0%~100%RH
Temperature –30°C~ 100°C, -30°F~ 199°F
Resolution 0.01% RH, 0.01°C/F
Humidity Accuracy
± 2%RH (at 25°C, 20%~80% RH)
± 2.5%RH (at other ranges)
Note : The measuring range is from 0% to 100%, but above 80% and below 20% the deviation is not specified
Air Temperature Accuracy ± 0.5°C/± 0.9°F (at 25°C)
.+ 0.8°C/+ 1.5°F (all other ranges)

 

Criteria Range
Humidity 0 to 100%RH
Temperature (Internal) -22 to 199°F (-30 to 100°C)
Basic Accuracy ±2%RH, ±1.8°F/1°C
Max. Resolution 0.1%RH, 0.1°F/°C
Dewpoint -22 to 199°F (-30 to 100°C)
Wet Bulb 32 to 176 °F (0 to 80°C)
Dimensions 7.8×1.7×1.3″ (200x45x33mm)
Weight 7oz (200g)

 

QUICK TIP:

HUMIDITY AND AIR TEMPERATURE MEASUREMENTS

1. Hold the probe in the area to be tested & allow adequate time for readings to stabilize.
2. Press °F,°C, dew point, WBT select button to enter select °F,°C, dew point Wet Bulb Measurement.
3. Read the Relative Humidity and Air Temperature, dew point temperature wet-bulb temperature.

Download Manual

What is the most accurate hygrometer/thermometer / psychrometer? It depends on multiple criteria. In this case, the unit provides the highest RH accuracy (2%) with 30 seconds response time.

Hygrometer-laboratory-geneq-2021Ideal for laboratory, industrial, wine cellar, engineering, and other professional uses, it is a high-end and professional instrument.

Combines the functions of a humidity meter, temperature meter, wet bulb thermometer, and dew point thermometer. 

A dual-illuminated readout can display wet bulb & humidity,  dew point & humidity, or temperature & humidity. Temperatures from -22 degrees to 199 degrees F (-30 degrees to 100 degrees C) and the full spectrum of relative humidity with ±2% accuracy between 20 and 90% RH. Complete with carrying case and 9V battery.

As a professional precision hygrometer, this unit meets strict quality criteria:

  • Fast Response Time %RH: 10S (90% at 25ºC still air)
  • High accuracy
  • Dew Point Temperature
  • Wet Bulb Temperature
  • Resolution 0.01%RH, 0.01ºC/0.01°F
  • Max Hold and Data Hold Function
  • Micro Processor-based Design
  • Dual Display Temperature & Humidity
  • Auto Power Off, Disable Sleep Mode
  • Backlight Display
  • Small Size
  • Slim design with rubberized sides for better grip and one-hand operation

One of the best hygrometers, now available in Canada

Display Large 4-1/2 dual digital LCD display with backlight
Sensor Type
A single-chip relative humidity and temperature multi-sensor module comprising a calibrated digital output.
Response Time %RH: 10S (90% at +25°C still air)
Accuracy Note Accuracy is specified for the following ambient temperature range: 64 to 82°F (18 to 28°C)
Sampling Rate 2.5 samples per second
Polarity Automatic, (-)negative polarity indication
Over-range “OL” mark indication
Low Battery Indication The “ ” is displayed when the battery voltage drops below the operating level.
Operating Conditions 32 to 104°F (0 to 40°C); < 80% RH non-condensing
Storage Conditions 14 to 140°F (-10 to 60°C); <80% RH non-condensing
Auto Power Off Meter automatically shuts down after approx.15 minutes of inactivity (Sleep Mode)
Power
Disable Option
One standard 9V, NEDA1604 or 6F22 battery
Dimensions/Wt. 225 (H) x 45 (W) x 34 (D) mm/200g
Humidity / Temperature Measurement Range
Humidity 0%~100%RH
Temperature –30°C~ 100°C, -30°F~ 199°F
Resolution 0.01% RH, 0.01°C/F
Humidity Accuracy
± 2%RH (at 25°C, 20%~80% RH)
± 2.5%RH (at other ranges)
Note : The measuring range is from 0% to 100%, but above 80% and below 20% the deviation is not specified
Air Temperature Accuracy ± 0.5°C/± 0.9°F (at 25°C)
.+ 0.8°C/+ 1.5°F (all other ranges)

 

Criteria Range
Humidity 0 to 100%RH
Temperature (Internal) -22 to 199°F (-30 to 100°C)
Basic Accuracy ±2%RH, ±1.8°F/1°C
Max. Resolution 0.1%RH, 0.1°F/°C
Dewpoint -22 to 199°F (-30 to 100°C)
Wet Bulb 32 to 176 °F (0 to 80°C)
Dimensions 7.8×1.7×1.3″ (200x45x33mm)
Weight 7oz (200g)

 

QUICK TIP:

HUMIDITY AND AIR TEMPERATURE MEASUREMENTS

1. Hold the probe in the area to be tested & allow adequate time for readings to stabilize.
2. Press °F,°C, dew point, WBT select button to enter select °F,°C, dew point Wet Bulb Measurement.
3. Read the Relative Humidity and Air Temperature, dew point temperature wet-bulb temperature.