RHTemp1000 is a compact, humidity and temperature data logger. Includes ISO17025 accredited calibration certificate.
This device measures and records temperatures from -40 °C to +80 °C (-40 °F to +176 °F) with an accuracy of ±0.5 °C.The RHTemp1000 can store up to 32,768 time and date stamped readings, and is able to be programmed to start up to 24 months in advance.
The RHTemp1000 is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy.Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.
Features
-
- Software Battery Life Indicator
- 316 Stainless Steel Enclosure
- Small, Sleek Design
- Fast Response Time
- Engraved Label
- CE Compliant
Specifications
General | |
Memory | 32,768 readings (all channels enabled) |
Reading Rate | 1 reading every second up to 1 reading every 24 hours |
Battery Life | 2 years typical at 25 °C, 15 minute reading intervals |
Material | 316 Stainless Steel/Radel |
Dimensions | 1.7 in x 0.97 in x 0.97 in (42 mm x 24.6 mm x 24.6 mm) |
Operating Environment | -40 °C to +80 °C (-40 °F to +176 °F),0 %RH to 100 %RH (non-condensing) |
Required Interface Package | IFC400 or IFC406 |
Approvals | CE |
Temperature | |
Temperature Sensor | Resistance Temperature Detector (RTD) |
Temperature Range | -40 °C to +80 °C (-40 °F to +176 °F) |
Temperature Resolution | 0.01 °C (0.018 °F) |
Temperature Response Time in Air | t63 – 8 minutes to 63% of change t90 – 68 minutes to 90% of change |
Temperature Calibrated Accuracy | ±0.5 °C (0 °C to +55 °C) |
Humidity | |
Humidity Sensor | Capacitive Polymer |
Humidity Range | 0 %RH to 100 %RH (non-condensing) |
Humidity Resolution | 0.1 %RH |
Humidity Response Time in Air | t90 – 2 minutes to 90% of change |
Humidity Calibrated Accuracy | ±3 %RH maximum |
Humidity Specified Accuracy Range | 25 %RH to 75 %RH +20 °C to +40 °C Hysteresis Error 1 % Typical, 3% Maximum. |
RHTemp1000 is a compact, humidity and temperature data logger. Includes ISO17025 accredited calibration certificate.
This device measures and records temperatures from -40 °C to +80 °C (-40 °F to +176 °F) with an accuracy of ±0.5 °C.The RHTemp1000 can store up to 32,768 time and date stamped readings, and is able to be programmed to start up to 24 months in advance.
The RHTemp1000 is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy.Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.
Features
-
- Software Battery Life Indicator
- 316 Stainless Steel Enclosure
- Small, Sleek Design
- Fast Response Time
- Engraved Label
- CE Compliant
Specifications
General | |
Memory | 32,768 readings (all channels enabled) |
Reading Rate | 1 reading every second up to 1 reading every 24 hours |
Battery Life | 2 years typical at 25 °C, 15 minute reading intervals |
Material | 316 Stainless Steel/Radel |
Dimensions | 1.7 in x 0.97 in x 0.97 in (42 mm x 24.6 mm x 24.6 mm) |
Operating Environment | -40 °C to +80 °C (-40 °F to +176 °F),0 %RH to 100 %RH (non-condensing) |
Required Interface Package | IFC400 or IFC406 |
Approvals | CE |
Temperature | |
Temperature Sensor | Resistance Temperature Detector (RTD) |
Temperature Range | -40 °C to +80 °C (-40 °F to +176 °F) |
Temperature Resolution | 0.01 °C (0.018 °F) |
Temperature Response Time in Air | t63 – 8 minutes to 63% of change t90 – 68 minutes to 90% of change |
Temperature Calibrated Accuracy | ±0.5 °C (0 °C to +55 °C) |
Humidity | |
Humidity Sensor | Capacitive Polymer |
Humidity Range | 0 %RH to 100 %RH (non-condensing) |
Humidity Resolution | 0.1 %RH |
Humidity Response Time in Air | t90 – 2 minutes to 90% of change |
Humidity Calibrated Accuracy | ±3 %RH maximum |
Humidity Specified Accuracy Range | 25 %RH to 75 %RH +20 °C to +40 °C Hysteresis Error 1 % Typical, 3% Maximum. |