The all-in-one wireless temperature and humidity logger RTR503B has a temperature measurement range of 0-55℃ and can measure humidity from 10 to 95%RH.
Great for harsh environment temperature / humidity monitoring, Splash proof
The RTR-503 logger has an external sensor for measuring temperature and humidity levels simultaneously. This unit is splash-proof and holds up well in environments with harsh temperatures and humidity levels. It will work with any of the RTR-500 series data collectors.
Features
- Measurement Range: Temperature: 0 to 55°C
- Humidity: 10 to 95 %RH
- Wireless Collection of Recorded Data
- Automatic Data Upload
- Warning Monitoring Function
Collect Data via Wireless Communication with a Base Unit
Our RTR500B series data loggers function as remote units and must be used with one of our collection devices (base unit).
The collected data can then be transmitted to a PC, our free cloud service or your FTP server using various methods such as USB, LAN and 3G network. In addition, various functions such as tracking current readings and warning notifications make it a powerful data management system.
* Select a Base Unit according to the type and scale of the measuring environment.
Features – All-in-one wireless temperature and humidity logger
The RTR503B recorders have a wireless radio communication range with compatible base units of up to 150m (500ft).
Data can be transmitted from a logger to a base unit, then automatically uploaded to cloud storage or saved to a specific location. Data can also be verified on your PC screen or on site with one of our compatible data collectors.
The RTR-503B wireless temperature and humidity logger, with its wireless radio communication capabilities, is perfect for applications where the temperature and humidity of various measurement points are managed at the same time, such as in temperature-controlled storage facilities and warehouses.
RTR-503B Specifications
RTR503B / 503BL |
||
Measurement Channels | Temperature 1ch | Humidity 1ch |
Sensor | Thermistor | Polymer Resistance |
Measurement Units | °C, °F | %RH |
Measurement Range | 0 to 55 °C | 10 to 95 %RH |
Accuracy | Avg.±0.3 °C | ±5 %RH
at 25 °C, 50%RH |
Measurement Resolution | 0.1°C | 1 %RH |
Responsiveness | Response Time (90%):
Approx. 7 min. |
|
Logging Capacity | 8,000 data sets
(One data set consists of readings for multiple channels.) |
Recording Interval |
Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min. |
|||
Recording Mode (*2) |
Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full) |
|||
LCD Display Items |
Measurements (alternating display for multiple channel devices), Battery Life Warning, etc. |
|||
Communication Interfaces |
Short Range Wireless Communication <For US> Frequency Range: 902 to 928MHz RF Power: 7mW Transmission Range: Approx. 150 meters (500 ft) if direct and unobstructed <For EU> Frequency Range: 869.7 to 870MHz RF Power: 5mW Transmission Range: Approx. 150 meters (500 ft) if direct and unobstructed Bluetooth 4.2 (Bluetooth Low Energy) (*3) Optical Communication |
|||
Power |
Lithium Battery: LS14250 x 1 L Type: Large Capacity Battery Kit RTR-500B1 (*4) External Power Adaptor Kit RTR-500A2 (*5) |
|||
Battery Life (*6) |
Approx. 10 months L Type: About 4 years |
|||
Dimensions |
H 62 mm x W 47 mm x D 19 mm L type: H 62 mm x W 47 mm x D 46.5 mm (excluding protrusions and sensor) Antenna length: 24 mm |
|||
Weight |
Approx. 50 g L Type: approx. 65 g |
|||
Operating Environment |
-40 to 80°C -30 to 80°C during wireless communication |
|||
Waterproof Capacity |
IP67: Immersion proof |
IP64: Splash proof (rated for use in daily life) (*7) |
||
Accessories |
– |
Temperature Sensor TR-5106 |
Temperature-Humidity Sensor TR-3310 |
High Precision temperature-humidity Sensor SHB-3101 |
Lithium Battery LS14250 or Large Capacity Battery Kit RTR-500B1, Strap (Not included with L type models), Manual Set (Warranty included) |
||||
Compatible Base Units |
RTR500BC, RTR500BW, RTR500BM RTR-500DC, RTR-500MBS-A, RTR-500NW/AW (*8) (*9) RTR-500 (*9) |
*1: When continually used in environments with temperatures above 60°C, the accuracy of humidity measurements will decrease over time. Also, humidity cannot be measured at temperatures below -20°C.
*2: Only “Endless” is available when using the RTR500BW, RTR500BM, RTR-500NW/AW, or RTR-500MBS-A as a Base Unit.
*3: Bluetooth is available when using the RTR500BW as a Base Unit and making device settings in the mobile app (T&D 500B Utility).
*4: When using RTR-500B1 it is necessary to purchase a Lithium Battery (LS26500). For details, contact your local authorized distributor.
*5: RTR-500A2 should not be used with the RTR501B, as it will cause the RTR-501 to display a higher than actual temperature reading of up to 3°C.
*6: Battery life depends on several factors, including ambient temperature, radio environment, frequency of communication, recording interval, and quality of the battery being used. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life.
*7: This is the waterproof capacity of the data logger with the sensor connected. Note that the temperature-humidity sensor is not water-resistant.
The specifications listed above are subject to change without notice.
QUICK TIP:
When it is time for the battery to be replaced, a battery warning mark will appear. Please change the battery as soon as possible a battery mark appears. If you continue to use the logger without changing the battery, the current temperature and (bAtt) will be displayed alternately and wireless communication will stop. ( Recording will continue).
• If the battery is further left unchanged, the display will automatically shut off, and play previously recorded data will be lost.
• Although the logger continues to work for a period after the battery has been removed, leaving the device without a battery until the LCD display goes blank will cause all recorded data to be lost.
This is a remote unit. In order to use wireless communication, it is necessary to purchase a base station separately.
(Compatible base units: RTR-500NW, RTR500AW, RTR-500, RTR-500DC, RTR-500GSM)
Learn more in the Instruction Manual / Quick Start Guide
The all-in-one wireless temperature and humidity logger RTR503B has a temperature measurement range of 0-55℃ and can measure humidity from 10 to 95%RH.
Great for harsh environment temperature / humidity monitoring, Splash proof
The RTR-503 logger has an external sensor for measuring temperature and humidity levels simultaneously. This unit is splash-proof and holds up well in environments with harsh temperatures and humidity levels. It will work with any of the RTR-500 series data collectors.
Features
- Measurement Range: Temperature: 0 to 55°C
- Humidity: 10 to 95 %RH
- Wireless Collection of Recorded Data
- Automatic Data Upload
- Warning Monitoring Function
Collect Data via Wireless Communication with a Base Unit
Our RTR500B series data loggers function as remote units and must be used with one of our collection devices (base unit).
The collected data can then be transmitted to a PC, our free cloud service or your FTP server using various methods such as USB, LAN and 3G network. In addition, various functions such as tracking current readings and warning notifications make it a powerful data management system.
* Select a Base Unit according to the type and scale of the measuring environment.
Features – All-in-one wireless temperature and humidity logger
The RTR503B recorders have a wireless radio communication range with compatible base units of up to 150m (500ft).
Data can be transmitted from a logger to a base unit, then automatically uploaded to cloud storage or saved to a specific location. Data can also be verified on your PC screen or on site with one of our compatible data collectors.
The RTR-503B wireless temperature and humidity logger, with its wireless radio communication capabilities, is perfect for applications where the temperature and humidity of various measurement points are managed at the same time, such as in temperature-controlled storage facilities and warehouses.
RTR-503B Specifications
RTR503B / 503BL |
||
Measurement Channels | Temperature 1ch | Humidity 1ch |
Sensor | Thermistor | Polymer Resistance |
Measurement Units | °C, °F | %RH |
Measurement Range | 0 to 55 °C | 10 to 95 %RH |
Accuracy | Avg.±0.3 °C | ±5 %RH
at 25 °C, 50%RH |
Measurement Resolution | 0.1°C | 1 %RH |
Responsiveness | Response Time (90%):
Approx. 7 min. |
|
Logging Capacity | 8,000 data sets
(One data set consists of readings for multiple channels.) |
Recording Interval |
Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min. |
|||
Recording Mode (*2) |
Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full) |
|||
LCD Display Items |
Measurements (alternating display for multiple channel devices), Battery Life Warning, etc. |
|||
Communication Interfaces |
Short Range Wireless Communication <For US> Frequency Range: 902 to 928MHz RF Power: 7mW Transmission Range: Approx. 150 meters (500 ft) if direct and unobstructed <For EU> Frequency Range: 869.7 to 870MHz RF Power: 5mW Transmission Range: Approx. 150 meters (500 ft) if direct and unobstructed Bluetooth 4.2 (Bluetooth Low Energy) (*3) Optical Communication |
|||
Power |
Lithium Battery: LS14250 x 1 L Type: Large Capacity Battery Kit RTR-500B1 (*4) External Power Adaptor Kit RTR-500A2 (*5) |
|||
Battery Life (*6) |
Approx. 10 months L Type: About 4 years |
|||
Dimensions |
H 62 mm x W 47 mm x D 19 mm L type: H 62 mm x W 47 mm x D 46.5 mm (excluding protrusions and sensor) Antenna length: 24 mm |
|||
Weight |
Approx. 50 g L Type: approx. 65 g |
|||
Operating Environment |
-40 to 80°C -30 to 80°C during wireless communication |
|||
Waterproof Capacity |
IP67: Immersion proof |
IP64: Splash proof (rated for use in daily life) (*7) |
||
Accessories |
– |
Temperature Sensor TR-5106 |
Temperature-Humidity Sensor TR-3310 |
High Precision temperature-humidity Sensor SHB-3101 |
Lithium Battery LS14250 or Large Capacity Battery Kit RTR-500B1, Strap (Not included with L type models), Manual Set (Warranty included) |
||||
Compatible Base Units |
RTR500BC, RTR500BW, RTR500BM RTR-500DC, RTR-500MBS-A, RTR-500NW/AW (*8) (*9) RTR-500 (*9) |
*1: When continually used in environments with temperatures above 60°C, the accuracy of humidity measurements will decrease over time. Also, humidity cannot be measured at temperatures below -20°C.
*2: Only “Endless” is available when using the RTR500BW, RTR500BM, RTR-500NW/AW, or RTR-500MBS-A as a Base Unit.
*3: Bluetooth is available when using the RTR500BW as a Base Unit and making device settings in the mobile app (T&D 500B Utility).
*4: When using RTR-500B1 it is necessary to purchase a Lithium Battery (LS26500). For details, contact your local authorized distributor.
*5: RTR-500A2 should not be used with the RTR501B, as it will cause the RTR-501 to display a higher than actual temperature reading of up to 3°C.
*6: Battery life depends on several factors, including ambient temperature, radio environment, frequency of communication, recording interval, and quality of the battery being used. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life.
*7: This is the waterproof capacity of the data logger with the sensor connected. Note that the temperature-humidity sensor is not water-resistant.
The specifications listed above are subject to change without notice.
QUICK TIP:
When it is time for the battery to be replaced, a battery warning mark will appear. Please change the battery as soon as possible a battery mark appears. If you continue to use the logger without changing the battery, the current temperature and (bAtt) will be displayed alternately and wireless communication will stop. ( Recording will continue).
• If the battery is further left unchanged, the display will automatically shut off, and play previously recorded data will be lost.
• Although the logger continues to work for a period after the battery has been removed, leaving the device without a battery until the LCD display goes blank will cause all recorded data to be lost.
This is a remote unit. In order to use wireless communication, it is necessary to purchase a base station separately.
(Compatible base units: RTR-500NW, RTR500AW, RTR-500, RTR-500DC, RTR-500GSM)
Learn more in the Instruction Manual / Quick Start Guide