Model
FCS-M
High performance controller with up to 128 channel configurations, comes with Modbus LAN communication, Modbus WAN output, 4 internal 5A @240 VAC SPDT relays, 2 strobe / horn alarm outputs, standard door mounted buzzer, graphic 8.1 cm (3.2 in) LCD resistive touch screen display and data logging
Description
High performance Controller with logic and priority settings for monitoring toxic, combustible and refrigerant gases with versatile control functionality
The FCS Flexible Control System is a sophisticated, high performance controller that offers multi-channel configurations for monitoring toxic, combustible and refrigerant gases with versatile control functionality for non-hazardous, non-explosion rated, commercial and light industrial applications. The FCS is designed to accept inputs from digital and/or analog transmitters and/or Peripheral Devices (in various combinations),using Modbus® RTU RS-485 or 4-20 mA analog input.
The FCS is available in 4 channel, 8 channel, 32 channel and 128 channel models with either Modbus® RTU RS-485 WAN output or with BACnet® MS/TP RS-485 WAN output for communicating with a Building Automation System (BAS).
All models include, four configurable SPDT dry contact relays with field configurable time delays and trigger levels, a full colour LCD resistive touch screen with LED panel indicating configurable channel alarm status, relay status and fault conditions, intuitive menu system with password protection, enhanced logic control, priorities/zoning capabilities, a USB port for firmware upgrades, data logging and a door-mounted, audible alarm. The FCS has flexible configuration settings for analog outputs and supports 4-20 mA and Modbus® driven VFDs.
Optional value added features include, analog inputs and/or analog outputs, a top mounted strobe, a locking door, a manual shut off switch and a water tight, door-mounted audible alarm.
Features
- Available in 4 channels, 8 channels, 32 channels and 128 channels
- FCS-M models offer Modbus® RTU RS-485 digital output signal for LAN and WAN communications
- FCS-B models offer BACnet® MS/TP RS-485 output signal for WAN communications (for communicating with a BAS)
- Graphic, full colour, touchpad LCD screen with LED indicators
- Intuitive menu system with password protection
- Optional internal analog inputs and/or analog outputs with flexible configuration settings
- Enhanced logic control, zoning and priority structure capabilities
- Supports 4-20 mA and Modbus® driven VFDs
- 4 dry contact relays, 5A @ 240V each
- 2 dedicated horn/strobe output drives, 0.5A @ 24VDC max
- Line Voltage (90 – 240 VAC)
- USB port for firmware upgrades and data logging
- Configurable to comply with California Title-24 Energy Efficiency Standards
- Door mounted audible alarm, optional water tight version available
- Standard water / dust tight, corrosion resistant enclosure (drip proof); IP54 rated with water tight, door mounted audible alarm installed
The FCS can be connected to the following CET remote devices:
- Remote strobe/horns
- Remote Display Module (CET-RDM)
- Remote Relay Module (RLY-4 and/or RLY-8)
- LNK-AI Analog Input device
- LNK-AO Analog Output device
- LNK-XT Network Extender
- Remote Power Supply (RPS-24VDC)
Specifications
Mechanical
Enclosure | ABS / Polycarbonate, copper coated interior to reduce RF interference IP54 rating with door mounted, water tight buzzer installed |
Weight | 1.8 kg / 4 lbs |
Size | 254 x 226 x 113 mm / 10.0 x 8.9 x 4.44 in |
User Interface
Display | 8.1 cm (3.2”) graphic, 1/4 VGA full colour resistive touch LCD screen with LED indicators for “POWER”, “STATUS 1, 2 and 3” and “FAULT” |
Input/Output
Input | Modbus® RTU RS-485 input 4-20 mA analog input (optional) |
Output | Modbus® RTU RS-485 output to networked devices Modbus® RTU RS-485 output to BAS or DDC (FCS-M models) BACnet MS/TP RS-485 output to BAS or DDC (FCS-B models) 2 outputs drives for strobe/horn, 0.5 A @ 24 VDC max Field configurable 4-20 mA or 0-10 volts analog output (optional) |
Relays | 4 internal SPDT dry contact relays, 5 A @ 240 VAC |
Audible Alarm | Standard loud, door mounted buzzer, 90 dB @ 30 cm (1 ft) Optional: door mounted, water tight buzzer, 85 dB @ 60.96 cm (2 ft) |
Top Mounted Strobe | Optional: bright, red, top mounted strobe, 10 – 30 VDC, 13 cm H x 6.1 cm dia / 5.2 inches H x 2.4 inches dia |
Electrical
Power Requirement | Line Voltage: 90 – 240 VAC, 50 -60 Hz, 75 W |
Current Draw | Line Voltage (110 VAC): approx. 1.0 amps Line Voltage (220 VAC): approx. 0.5 amps |
Power Distribution | Total power available for Remote & Peripheral Devices and Options 65 W @ 24 VDC |
Wiring | Line Voltage: VAC 3-conductor shielded minimum 18 AWG stranded within conduit LAN Modbus® RTU (version 1.1b3) RS-485, 16 gauge, 4-conductor shielded WAN (output to BAS only): Modbus® RS-485 or BACnet® MS/TP, 4-conductor shielded |
Fuses | Thermal, resetting |
Environmental
Operating Temperature | -20°C to 40°C (-4°F to 104°F) |
with internal heater | -40°C to -40°C (-40°F to 104°F) |
Operating Humidity | 15 – 90% RH non-condensing |
Certifications
Conforms to: | CSA-C22.2 No. 205-12, UL508 (Edition 17):2007 EMC Directive 2004/108/EC, EN 50270:2006, Type 1, EN61010 FCC. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCS-B, FCS-B-X models are Listed by BTL (where X represents one or more factory installed Options) RoHS compliant circuit boards |
Model
FCS-M
High performance controller with up to 128 channel configurations, comes with Modbus LAN communication, Modbus WAN output, 4 internal 5A @240 VAC SPDT relays, 2 strobe / horn alarm outputs, standard door mounted buzzer, graphic 8.1 cm (3.2 in) LCD resistive touch screen display and data logging
Description
High performance Controller with logic and priority settings for monitoring toxic, combustible and refrigerant gases with versatile control functionality
The FCS Flexible Control System is a sophisticated, high performance controller that offers multi-channel configurations for monitoring toxic, combustible and refrigerant gases with versatile control functionality for non-hazardous, non-explosion rated, commercial and light industrial applications. The FCS is designed to accept inputs from digital and/or analog transmitters and/or Peripheral Devices (in various combinations),using Modbus® RTU RS-485 or 4-20 mA analog input.
The FCS is available in 4 channel, 8 channel, 32 channel and 128 channel models with either Modbus® RTU RS-485 WAN output or with BACnet® MS/TP RS-485 WAN output for communicating with a Building Automation System (BAS).
All models include, four configurable SPDT dry contact relays with field configurable time delays and trigger levels, a full colour LCD resistive touch screen with LED panel indicating configurable channel alarm status, relay status and fault conditions, intuitive menu system with password protection, enhanced logic control, priorities/zoning capabilities, a USB port for firmware upgrades, data logging and a door-mounted, audible alarm. The FCS has flexible configuration settings for analog outputs and supports 4-20 mA and Modbus® driven VFDs.
Optional value added features include, analog inputs and/or analog outputs, a top mounted strobe, a locking door, a manual shut off switch and a water tight, door-mounted audible alarm.
Features
- Available in 4 channels, 8 channels, 32 channels and 128 channels
- FCS-M models offer Modbus® RTU RS-485 digital output signal for LAN and WAN communications
- FCS-B models offer BACnet® MS/TP RS-485 output signal for WAN communications (for communicating with a BAS)
- Graphic, full colour, touchpad LCD screen with LED indicators
- Intuitive menu system with password protection
- Optional internal analog inputs and/or analog outputs with flexible configuration settings
- Enhanced logic control, zoning and priority structure capabilities
- Supports 4-20 mA and Modbus® driven VFDs
- 4 dry contact relays, 5A @ 240V each
- 2 dedicated horn/strobe output drives, 0.5A @ 24VDC max
- Line Voltage (90 – 240 VAC)
- USB port for firmware upgrades and data logging
- Configurable to comply with California Title-24 Energy Efficiency Standards
- Door mounted audible alarm, optional water tight version available
- Standard water / dust tight, corrosion resistant enclosure (drip proof); IP54 rated with water tight, door mounted audible alarm installed
The FCS can be connected to the following CET remote devices:
- Remote strobe/horns
- Remote Display Module (CET-RDM)
- Remote Relay Module (RLY-4 and/or RLY-8)
- LNK-AI Analog Input device
- LNK-AO Analog Output device
- LNK-XT Network Extender
- Remote Power Supply (RPS-24VDC)
Specifications
Mechanical
Enclosure | ABS / Polycarbonate, copper coated interior to reduce RF interference IP54 rating with door mounted, water tight buzzer installed |
Weight | 1.8 kg / 4 lbs |
Size | 254 x 226 x 113 mm / 10.0 x 8.9 x 4.44 in |
User Interface
Display | 8.1 cm (3.2”) graphic, 1/4 VGA full colour resistive touch LCD screen with LED indicators for “POWER”, “STATUS 1, 2 and 3” and “FAULT” |
Input/Output
Input | Modbus® RTU RS-485 input 4-20 mA analog input (optional) |
Output | Modbus® RTU RS-485 output to networked devices Modbus® RTU RS-485 output to BAS or DDC (FCS-M models) BACnet MS/TP RS-485 output to BAS or DDC (FCS-B models) 2 outputs drives for strobe/horn, 0.5 A @ 24 VDC max Field configurable 4-20 mA or 0-10 volts analog output (optional) |
Relays | 4 internal SPDT dry contact relays, 5 A @ 240 VAC |
Audible Alarm | Standard loud, door mounted buzzer, 90 dB @ 30 cm (1 ft) Optional: door mounted, water tight buzzer, 85 dB @ 60.96 cm (2 ft) |
Top Mounted Strobe | Optional: bright, red, top mounted strobe, 10 – 30 VDC, 13 cm H x 6.1 cm dia / 5.2 inches H x 2.4 inches dia |
Electrical
Power Requirement | Line Voltage: 90 – 240 VAC, 50 -60 Hz, 75 W |
Current Draw | Line Voltage (110 VAC): approx. 1.0 amps Line Voltage (220 VAC): approx. 0.5 amps |
Power Distribution | Total power available for Remote & Peripheral Devices and Options 65 W @ 24 VDC |
Wiring | Line Voltage: VAC 3-conductor shielded minimum 18 AWG stranded within conduit LAN Modbus® RTU (version 1.1b3) RS-485, 16 gauge, 4-conductor shielded WAN (output to BAS only): Modbus® RS-485 or BACnet® MS/TP, 4-conductor shielded |
Fuses | Thermal, resetting |
Environmental
Operating Temperature | -20°C to 40°C (-4°F to 104°F) |
with internal heater | -40°C to -40°C (-40°F to 104°F) |
Operating Humidity | 15 – 90% RH non-condensing |
Certifications
Conforms to: | CSA-C22.2 No. 205-12, UL508 (Edition 17):2007 EMC Directive 2004/108/EC, EN 50270:2006, Type 1, EN61010 FCC. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCS-B, FCS-B-X models are Listed by BTL (where X represents one or more factory installed Options) RoHS compliant circuit boards |