BREWLAB® PRO – WATER ANALYSIS KIT

LaMotte - 7190
It measures 11 test factors which are important in the brewing process

$1,199.00 CAD

Support, maintenance, calibration –
1 800 463-4363

 

BrewLab® Pro – the professional test kit for craft brewing

LaMotte introduces the new BrewLab® Pro water analysis kit. Designed with the professional brewer in mind, this kit measures 11 test factors which are important in the brewing process. Water is the most important ingredient for any brewer. The BrewLab® Pro helps you to make your best craft brew and reproduce your results time and time again!

Test for 11 Essential Factors

  • Chloride
  • Sulfate
  • Alkalinity
  • Total Hardness
  • Calcium Hardness
  • Magnesium Hardness
  • Sodium
  • pH
  • Temperature
  • Total Dissolved Solids
  • Dissolved Oxygen

Specifications

Test Factor Test System Range # of Tests
Chloride Direct Reading Titrator 1 drop = 10ppm, 25 ppm Approx. 80
Sulfate Turbidimetric 0-200 ppm sulfate 50
Alkalinity Direct Reading Titrator 0-200 ppm (and higher) as CaCO3 50 at 200 ppm
Total Hardness Direct Reading Titrator 0-200 ppm (and higher) as CaCO3 50 at 200 ppm
Calcium Hardness Direct Reading Titrator 0-200 ppm (and higher) as CaCO3 50 at 200 ppm
Magnesium Hardness Calculation
Sodium Calculation
pH Electrometric 0.0-14.0 pH Unlimited
Temperature Electrometric 32 to 149°F (0 to 65°C) Unlimited
Total Dissolved Solids Electrometric 0 to 99.9 ppm (mg/L),
100 to 999 ppm (mg/L),
1.00 to 9.99 ppt
Unlimited
Dissolved Oxygen (Sat. Mode) Electrometric 0 to 200.0% Unlimited
Dissolved Oxygen (Conc. Mode) Electrometric 0 to 20.00 ppm (mg/L) Unlimited

BrewLab® Pro – the professional test kit for craft brewing

LaMotte introduces the new BrewLab® Pro water analysis kit. Designed with the professional brewer in mind, this kit measures 11 test factors which are important in the brewing process. Water is the most important ingredient for any brewer. The BrewLab® Pro helps you to make your best craft brew and reproduce your results time and time again!

Test for 11 Essential Factors

  • Chloride
  • Sulfate
  • Alkalinity
  • Total Hardness
  • Calcium Hardness
  • Magnesium Hardness
  • Sodium
  • pH
  • Temperature
  • Total Dissolved Solids
  • Dissolved Oxygen

Specifications

Test Factor Test System Range # of Tests
Chloride Direct Reading Titrator 1 drop = 10ppm, 25 ppm Approx. 80
Sulfate Turbidimetric 0-200 ppm sulfate 50
Alkalinity Direct Reading Titrator 0-200 ppm (and higher) as CaCO3 50 at 200 ppm
Total Hardness Direct Reading Titrator 0-200 ppm (and higher) as CaCO3 50 at 200 ppm
Calcium Hardness Direct Reading Titrator 0-200 ppm (and higher) as CaCO3 50 at 200 ppm
Magnesium Hardness Calculation
Sodium Calculation
pH Electrometric 0.0-14.0 pH Unlimited
Temperature Electrometric 32 to 149°F (0 to 65°C) Unlimited
Total Dissolved Solids Electrometric 0 to 99.9 ppm (mg/L),
100 to 999 ppm (mg/L),
1.00 to 9.99 ppt
Unlimited
Dissolved Oxygen (Sat. Mode) Electrometric 0 to 200.0% Unlimited
Dissolved Oxygen (Conc. Mode) Electrometric 0 to 20.00 ppm (mg/L) Unlimited