Temperature humidity datalogger for food industry

MadgeTech - RHTemp1000
Ideal for use in harsh environments

$649.00 CAD

  • Compact Size
  • Memory Capacity of 32,000+ Readings
  • Measures Temperatures from -40 ºC to 80 ºC

Support, maintenance, calibration –
1 800 463-4363

 

SKU: MARHTEMP1000 Category: Tags: ,

RHTemp1000 is a compact, humidity and temperature data logger. Includes ISO17025 accredited calibration certificate.

This device measures and records temperatures from -40 °C to +80 °C (-40 °F to +176 °F) with an accuracy of ±0.5 °C.The RHTemp1000 can store up to 32,768 time and date stamped readings, and is able to be programmed to start up to 24 months in advance.

The RHTemp1000 is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy.Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.

Features

    • Software Battery Life Indicator
    • 316 Stainless Steel Enclosure
    • Small, Sleek Design
    • Fast Response Time
    • Engraved Label
    • CE Compliant

Specifications

General
Memory 32,768 readings (all channels enabled)
Reading Rate 1 reading every second up to 1 reading every 24 hours
Battery Life 2 years typical at 25 °C, 15 minute reading intervals
Material 316 Stainless Steel/Radel
Dimensions 1.7 in x 0.97 in x 0.97 in (42 mm x 24.6 mm x 24.6 mm)
Operating Environment -40 °C to +80 °C (-40 °F to +176 °F),0 %RH to 100 %RH (non-condensing)
Required Interface Package IFC400 or IFC406
Approvals CE
Temperature
Temperature Sensor Resistance Temperature Detector (RTD)
Temperature Range -40 °C to +80 °C (-40 °F to +176 °F)
Temperature Resolution 0.01 °C (0.018 °F)
Temperature Response Time in Air t63 – 8 minutes to 63% of change
t90 – 68 minutes to 90% of change
Temperature Calibrated Accuracy ±0.5 °C (0 °C to +55 °C)
Humidity
Humidity Sensor Capacitive Polymer
Humidity Range 0 %RH to 100 %RH (non-condensing)
Humidity Resolution 0.1 %RH
Humidity Response Time in Air t90 – 2 minutes to 90% of change
Humidity Calibrated Accuracy ±3 %RH maximum
Humidity Specified Accuracy Range 25 %RH to 75 %RH
+20 °C to +40 °C
Hysteresis Error 1 % Typical, 3% Maximum.

RHTemp1000 is a compact, humidity and temperature data logger. Includes ISO17025 accredited calibration certificate.

This device measures and records temperatures from -40 °C to +80 °C (-40 °F to +176 °F) with an accuracy of ±0.5 °C.The RHTemp1000 can store up to 32,768 time and date stamped readings, and is able to be programmed to start up to 24 months in advance.

The RHTemp1000 is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy.Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.

Features

    • Software Battery Life Indicator
    • 316 Stainless Steel Enclosure
    • Small, Sleek Design
    • Fast Response Time
    • Engraved Label
    • CE Compliant

Specifications

General
Memory 32,768 readings (all channels enabled)
Reading Rate 1 reading every second up to 1 reading every 24 hours
Battery Life 2 years typical at 25 °C, 15 minute reading intervals
Material 316 Stainless Steel/Radel
Dimensions 1.7 in x 0.97 in x 0.97 in (42 mm x 24.6 mm x 24.6 mm)
Operating Environment -40 °C to +80 °C (-40 °F to +176 °F),0 %RH to 100 %RH (non-condensing)
Required Interface Package IFC400 or IFC406
Approvals CE
Temperature
Temperature Sensor Resistance Temperature Detector (RTD)
Temperature Range -40 °C to +80 °C (-40 °F to +176 °F)
Temperature Resolution 0.01 °C (0.018 °F)
Temperature Response Time in Air t63 – 8 minutes to 63% of change
t90 – 68 minutes to 90% of change
Temperature Calibrated Accuracy ±0.5 °C (0 °C to +55 °C)
Humidity
Humidity Sensor Capacitive Polymer
Humidity Range 0 %RH to 100 %RH (non-condensing)
Humidity Resolution 0.1 %RH
Humidity Response Time in Air t90 – 2 minutes to 90% of change
Humidity Calibrated Accuracy ±3 %RH maximum
Humidity Specified Accuracy Range 25 %RH to 75 %RH
+20 °C to +40 °C
Hysteresis Error 1 % Typical, 3% Maximum.