The Mini vortex mixer Analog model offers variable speed control, and the digital model allows input of the exact speed and time to achieve reproducible results.
The pulsing model features a unique pulse action that reduces heat generation while providing more effective mixing and cell disruption. The fixed speed model offers one-touch, high-speed mixing.
Applications
Re-Suspending Liquids, Mixing Reagents, Buffers, and Emulsions, ELISA Assay, Drug Extractions, Mixing Samples
Display
Independent LED displays for speed/time allow the operator to view both settings simultaneously (digital models) and adjustment knob with dial markings for variable speed control (analog models)
Operation
Detachable 3-wire cord and plug (included)
Construction
Cup head and 3-inch accessory platform for beakers, flasks, test tubes etc. (included with all models),stainless steel microtube holder for 12 tubes (pulsing models)
Design Features
Microprocessor-control to maintain set speed for consistent mixing action (digital models),230V models have a maximum speed of 2500 rpm
Available as analog and digital models with a rocker switch to select from 2 modes – Touch mode which activates mixing when depressing the cup head or Continuous mode when using accessory attachments. | |
Analog and digital models offer speed control from low RPM start up for gentle shaking – to high-speed mixing for vigorous vortexing of samples (analog – 300 to 3200 rpm & digital – 500 to 3000 rpm). | |
Fixed speed vortex mixers start mixing when the cup head is depressed. Ideal for mixing samples when a variable speed is not needed. Speed is a full 3200 rpm to provide vigorous mixing of samples. |
The Mini vortex mixer 4 models:
VXMNFS | |
Control | Fixed Speed |
Duty Rating | Intermittent |
Orbit | 0.2 in (4.9 mm) |
Speed Range | 3200 rpm |
Dimensions (HxLxW) | 6.5 in x 8.3 in x 4.8 in (16.5 cm x 21 cm x 12.3 cm) |
Net Weight | 9.7 lb (4.4 kg) |
Power | 120V, 1.2A, 50/60Hz |
Power Consumption | 135 W |
Safety Certification | TUV |
Working Environment | 39°F – 104°F, 20% – 85%RH, non-condensing (4°C – 40°C, 20% – 85%RH, non-condensing) |
VXMNAL | |
Control | Analog |
Duty Rating | Intermittent |
Orbit | 0.2 in (4.9 mm) |
Speed Range | 300 rpm – 3200 rpm |
Net Weight | 9.7 lb (4.4 kg) |
Power | 120V, 1.2A, 50/60Hz |
Power Consumption | 135 W |
Safety Certification | TUV |
Working Environment | 39°F – 104°F, 20% – 85%RH, non-condensing (4°C – 40°C, 20% – 85%RH, non-condensing) |
VXMNDG | |
Control | Digital |
Duty Rating | Intermittent |
Orbit | 0.2 in (4.9 mm) |
Speed Range | 500 rpm – 3000 rpm |
Net Weight | 9.7 lb (4.4 kg) |
Power | 120V, 1.2A, 50/60Hz |
Power Consumption | 135 W |
Safety Certification | TUV |
Working Environment | 39°F – 104°F, 20% – 85%RH, non-condensing (4°C – 40°C, 20% – 85%RH, non-condensing) |
VXMNPS | |
Control | Pulsing |
Duty Rating | Intermittent |
Orbit | 0.1 in (2.5 mm) |
Speed Range | 500 rpm – 3000 rpm |
Net Weight | 9.7 lb (4.4 kg) |
Power | 120V, 1.2A, 50/60Hz |
Power Consumption | 135 W |
Safety Certification | TUV |
Working Environment | 39°F – 104°F, 20% – 85%RH, non-condensing (4°C – 40°C, 20% – 85%RH, non-condensing) |
QUICK TIP:
Operating Tips
These units are not intended for continuous use over extended periods of time. A built-in temperature sensor will prevent the unit from overheating by shutting the motor down. If this occurs, allow the motor to cool down and the unit will be able to resume normal operation. Decrease the duration of the time unit is used between rest periods.
The Mini vortex mixer Analog model offers variable speed control, and the digital model allows input of the exact speed and time to achieve reproducible results.
The pulsing model features a unique pulse action that reduces heat generation while providing more effective mixing and cell disruption. The fixed speed model offers one-touch, high-speed mixing.
Applications
Re-Suspending Liquids, Mixing Reagents, Buffers, and Emulsions, ELISA Assay, Drug Extractions, Mixing Samples
Display
Independent LED displays for speed/time allow the operator to view both settings simultaneously (digital models) and adjustment knob with dial markings for variable speed control (analog models)
Operation
Detachable 3-wire cord and plug (included)
Construction
Cup head and 3-inch accessory platform for beakers, flasks, test tubes etc. (included with all models),stainless steel microtube holder for 12 tubes (pulsing models)
Design Features
Microprocessor-control to maintain set speed for consistent mixing action (digital models),230V models have a maximum speed of 2500 rpm
Available as analog and digital models with a rocker switch to select from 2 modes – Touch mode which activates mixing when depressing the cup head or Continuous mode when using accessory attachments. | |
Analog and digital models offer speed control from low RPM start up for gentle shaking – to high-speed mixing for vigorous vortexing of samples (analog – 300 to 3200 rpm & digital – 500 to 3000 rpm). | |
Fixed speed vortex mixers start mixing when the cup head is depressed. Ideal for mixing samples when a variable speed is not needed. Speed is a full 3200 rpm to provide vigorous mixing of samples. |
The Mini vortex mixer 4 models:
VXMNFS | |
Control | Fixed Speed |
Duty Rating | Intermittent |
Orbit | 0.2 in (4.9 mm) |
Speed Range | 3200 rpm |
Dimensions (HxLxW) | 6.5 in x 8.3 in x 4.8 in (16.5 cm x 21 cm x 12.3 cm) |
Net Weight | 9.7 lb (4.4 kg) |
Power | 120V, 1.2A, 50/60Hz |
Power Consumption | 135 W |
Safety Certification | TUV |
Working Environment | 39°F – 104°F, 20% – 85%RH, non-condensing (4°C – 40°C, 20% – 85%RH, non-condensing) |
VXMNAL | |
Control | Analog |
Duty Rating | Intermittent |
Orbit | 0.2 in (4.9 mm) |
Speed Range | 300 rpm – 3200 rpm |
Net Weight | 9.7 lb (4.4 kg) |
Power | 120V, 1.2A, 50/60Hz |
Power Consumption | 135 W |
Safety Certification | TUV |
Working Environment | 39°F – 104°F, 20% – 85%RH, non-condensing (4°C – 40°C, 20% – 85%RH, non-condensing) |
VXMNDG | |
Control | Digital |
Duty Rating | Intermittent |
Orbit | 0.2 in (4.9 mm) |
Speed Range | 500 rpm – 3000 rpm |
Net Weight | 9.7 lb (4.4 kg) |
Power | 120V, 1.2A, 50/60Hz |
Power Consumption | 135 W |
Safety Certification | TUV |
Working Environment | 39°F – 104°F, 20% – 85%RH, non-condensing (4°C – 40°C, 20% – 85%RH, non-condensing) |
VXMNPS | |
Control | Pulsing |
Duty Rating | Intermittent |
Orbit | 0.1 in (2.5 mm) |
Speed Range | 500 rpm – 3000 rpm |
Net Weight | 9.7 lb (4.4 kg) |
Power | 120V, 1.2A, 50/60Hz |
Power Consumption | 135 W |
Safety Certification | TUV |
Working Environment | 39°F – 104°F, 20% – 85%RH, non-condensing (4°C – 40°C, 20% – 85%RH, non-condensing) |
QUICK TIP:
Operating Tips
These units are not intended for continuous use over extended periods of time. A built-in temperature sensor will prevent the unit from overheating by shutting the motor down. If this occurs, allow the motor to cool down and the unit will be able to resume normal operation. Decrease the duration of the time unit is used between rest periods.