Ultrasonic thickness gauge with A / B Scan & Thru Coating Capability

Phase II- UTG-4000
Measure the thickness of metallic and non-metallic materials in critical situations that ordinary thickness gauges couldn’t do.

$2,440.50 CAD

  • 12 months limited warranty
  • Auto shut-off after: 5 minutes
  • Resolution: 0.001 in., .01 in./0.01mm (selectable)
  • Display type: 2.4 in. color screen

Support, maintenance, calibration
1 800 463-4363

 

SKU: UTG-4000 Categories: , ,

Phase II UTG4000 Ultrasonic Thickness Gauge has A and B Scan as well as Thru Coating Capability, and utilizes color waveform A-scan and time-based B-scan for absolute correctness

This multi-functional ultrasonic thickness gauge offers everything from basic measurement, scan mode with Min/Max viewing, GO/NO GO display, adjustable sound velocity, and thru-coating capabilities.

This dynamic ultrasonic thickness gauge is designed to measure the thickness of metallic and non-metallic materials in critical situations that ordinary thickness gauges couldn’t do.

The UTG-4000 ultrasonic thickness gauge will accurately display readings in either inch or millimeter after a simple calibration to a known thickness or sound velocity.

Ultrasonic Thickness Gauge – Phase II UTG-4000 Ultrasonic thickness gauge Revised

 

Specifications

Operating Principle Ultrasonic pulse/echo method with the dual-element probe
Display type 2.4” Color Screen
Resolution 0.001”, .01” /0.01mm (selectable)
Measuring Range Standard Mode: 0.02-20.0” (10mm-145mm) Dependent upon probe & material

Thru-Coating Mode (E-E): 0.09″ to 0.984″

Repeatability +/-.001” (+/-0.05mm)
Sound velocity range 0.0197-0.3937in/us (500-9999m/s)
Measuring Error: 0.001”(up to 0.984”)
0.007”(up to 3.03”
0.019”( 4” and above)
Display Modes: Digital Thickness Readout
A-scan or Waveform
Min/Max Capture
D-Value / Reduction
V-Path Correction Automatic
Update rate Selectable: 4Hz, 8Hz, 16Hz
Refresh rate 4/second
Alarm Settings Min/Max Alarm
Dynamic waveform color change on alarm
Operating temperature 14-122ºF (-10ºC – +50ºC)
Auto Shut-Off After 5 minutes
Power supply 3v AA alkaline batteries (2pc)
Operating Time Approx. 36 hours
Dimensions 6.02” x 2.99” x 1.45” (153 x 76 x 37mm)
Weight 9.9oz (280g)

 
Phase II UTG-4000 Ultrasonic Thickness Gauge Features:

  • Ultrasonic Thickness Gauge w/ A & B Scan and Thru Capability
  • This handheld unit has the precise touch and reads capabilities yet is economically priced.
  • Designed to measure the thickness of metallic and non-metallic materials such as aluminum, titanium, plastics, ceramics, glass, and any other good ultrasonic wave conductor as long as it has parallel top and bottom surfaces.
  • The direct contact method of pulse/echo type ultrasonic thickness gauges requires the use of a couplant. Propylene Glycol is common, but many other substances can be used.
  • Easy to configure and use, many gauges today have the ability to retain memory, output to printers, PC’s, and handheld portable devices.

UTG-4000 Probe Specifications:

Part No.

UTG3000-400

UTG3000-475

UTG3000-404

UTG3000-440

UTG3000-450

Probe Style

Standard

Small Tube

Extreme small tube

Rough surface/
Porous metal

Hi-Temp

Frequency

5MHz

7.5 MHz

10 MHz

2 MHz

5 MHz

Contact Dia.

8mm

6mm

4mm

17mm

15mm

Measure range:

.031-3.93”

.031-1.18”

.019-.787”

.157-20”

.157-3.14”

Temperature

14-158ºF

14-158ºF

14-158ºF

14-158ºF

0-572ºF

Picture

 

 

 

utg-3000-475

utg-3000-404 UTG-3000-440 utg-3000-450

QUICK TIP:

Maintenance:

1. Always keep your gauge, probe, cable clean of any dirt, dust, fluids, etc to prevent early wear of these parts.
2. Be sure to avoid any caustic liquid such as alcohol or viscous fluids to prevent corrosion to the cover and the display window. Clean with water only.
3. Avoid scratching the surface of the probe. A worn probe will cause unstable readings.

 

Phase II UTG4000 Ultrasonic Thickness Gauge has A and B Scan as well as Thru Coating Capability, and utilizes color waveform A-scan and time-based B-scan for absolute correctness

This multi-functional ultrasonic thickness gauge offers everything from basic measurement, scan mode with Min/Max viewing, GO/NO GO display, adjustable sound velocity, and thru-coating capabilities.

This dynamic ultrasonic thickness gauge is designed to measure the thickness of metallic and non-metallic materials in critical situations that ordinary thickness gauges couldn’t do.

The UTG-4000 ultrasonic thickness gauge will accurately display readings in either inch or millimeter after a simple calibration to a known thickness or sound velocity.

Ultrasonic Thickness Gauge – Phase II UTG-4000 Ultrasonic thickness gauge Revised

 

Specifications

Operating Principle Ultrasonic pulse/echo method with the dual-element probe
Display type 2.4” Color Screen
Resolution 0.001”, .01” /0.01mm (selectable)
Measuring Range Standard Mode: 0.02-20.0” (10mm-145mm) Dependent upon probe & material

Thru-Coating Mode (E-E): 0.09″ to 0.984″

Repeatability +/-.001” (+/-0.05mm)
Sound velocity range 0.0197-0.3937in/us (500-9999m/s)
Measuring Error: 0.001”(up to 0.984”)
0.007”(up to 3.03”
0.019”( 4” and above)
Display Modes: Digital Thickness Readout
A-scan or Waveform
Min/Max Capture
D-Value / Reduction
V-Path Correction Automatic
Update rate Selectable: 4Hz, 8Hz, 16Hz
Refresh rate 4/second
Alarm Settings Min/Max Alarm
Dynamic waveform color change on alarm
Operating temperature 14-122ºF (-10ºC – +50ºC)
Auto Shut-Off After 5 minutes
Power supply 3v AA alkaline batteries (2pc)
Operating Time Approx. 36 hours
Dimensions 6.02” x 2.99” x 1.45” (153 x 76 x 37mm)
Weight 9.9oz (280g)

 
Phase II UTG-4000 Ultrasonic Thickness Gauge Features:

  • Ultrasonic Thickness Gauge w/ A & B Scan and Thru Capability
  • This handheld unit has the precise touch and reads capabilities yet is economically priced.
  • Designed to measure the thickness of metallic and non-metallic materials such as aluminum, titanium, plastics, ceramics, glass, and any other good ultrasonic wave conductor as long as it has parallel top and bottom surfaces.
  • The direct contact method of pulse/echo type ultrasonic thickness gauges requires the use of a couplant. Propylene Glycol is common, but many other substances can be used.
  • Easy to configure and use, many gauges today have the ability to retain memory, output to printers, PC’s, and handheld portable devices.

UTG-4000 Probe Specifications:

Part No.

UTG3000-400

UTG3000-475

UTG3000-404

UTG3000-440

UTG3000-450

Probe Style

Standard

Small Tube

Extreme small tube

Rough surface/
Porous metal

Hi-Temp

Frequency

5MHz

7.5 MHz

10 MHz

2 MHz

5 MHz

Contact Dia.

8mm

6mm

4mm

17mm

15mm

Measure range:

.031-3.93”

.031-1.18”

.019-.787”

.157-20”

.157-3.14”

Temperature

14-158ºF

14-158ºF

14-158ºF

14-158ºF

0-572ºF

Picture

 

 

 

utg-3000-475

utg-3000-404 UTG-3000-440 utg-3000-450

QUICK TIP:

Maintenance:

1. Always keep your gauge, probe, cable clean of any dirt, dust, fluids, etc to prevent early wear of these parts.
2. Be sure to avoid any caustic liquid such as alcohol or viscous fluids to prevent corrosion to the cover and the display window. Clean with water only.
3. Avoid scratching the surface of the probe. A worn probe will cause unstable readings.