Elcometer 456 Probe Range | Telescopic Probes

Elcometer 456 Probe Range
Ideal for measuring coatings up to 31mm thick.

$1,240.50 CAD

  • 12 MONTHS LIMITED WARRANTY
  • Designed to work with any of our Ferrous or Dual FNF Elcometer 456 Separate Gauges
  • For taking readings in areas with restricted access or head clearance.

All Elcometer 456 probes are fully interchangeable and are available in a number of designs and scale ranges to meet your specific application

Ferrous probes measure non magnetic coatings on ferro-magnetic substrates. Elcometer 456 ferrous gauges accept any ferrous probe. Non-ferrous probes measure non conductive coatings on non-ferrous metal substrates and Elcometer 456 non-ferrous gauges accept any non-ferrous probe. Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection. Elcometer 456 FNF gauges accept all ferrous, non-ferrous and dual FNF probes.

Unless stated, Elcometer separate probes have a maximum operating temperature of 150°C (300°F), PINIP™ probes have a maximum operating temperature of 80°C (176°F).

Every Elcometer 456 gauge and separate probe is supplied with a Test Certificate free of charge. For separate gauges, the test measurements are generated using factory reference probes.

Telescopic Probes

Product Description

Designed to work with any of our Ferrous or Dual FNF Elcometer 456 Separate Gauges.

For higher resolution & accuracy on thin coatings Scale 2 gauges can be switched to the Scale 1 mode measurement performance.

For taking readings in areas with restricted access or head clearance.

Specifications:

  • 22-48″
  • Range: 0-200 mils (0-5mm)
  • Accuracy: ±1-3% or ±1.0 mil (±20µm)
  • Resolution: 0.1 mil: 0-50 mils; 1mil: 50-200 mils (1µm: 0-1mm; 10µm: 1-5mm)
  • Minimum convex surface radius 4mm (0.16″)
  • Minimum concave surface radius 25mm (0.98″)
  • Minimum headroom 36mm (1.42″)
  • Minimum sample diameter: 8mm (0.32″)

All Elcometer 456 probes are fully interchangeable and are available in a number of designs and scale ranges to meet your specific application

Ferrous probes measure non magnetic coatings on ferro-magnetic substrates. Elcometer 456 ferrous gauges accept any ferrous probe. Non-ferrous probes measure non conductive coatings on non-ferrous metal substrates and Elcometer 456 non-ferrous gauges accept any non-ferrous probe. Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection. Elcometer 456 FNF gauges accept all ferrous, non-ferrous and dual FNF probes.

Unless stated, Elcometer separate probes have a maximum operating temperature of 150°C (300°F), PINIP™ probes have a maximum operating temperature of 80°C (176°F).

Every Elcometer 456 gauge and separate probe is supplied with a Test Certificate free of charge. For separate gauges, the test measurements are generated using factory reference probes.

Telescopic Probes

Product Description

Designed to work with any of our Ferrous or Dual FNF Elcometer 456 Separate Gauges.

For higher resolution & accuracy on thin coatings Scale 2 gauges can be switched to the Scale 1 mode measurement performance.

For taking readings in areas with restricted access or head clearance.

Specifications:

  • 22-48″
  • Range: 0-200 mils (0-5mm)
  • Accuracy: ±1-3% or ±1.0 mil (±20µm)
  • Resolution: 0.1 mil: 0-50 mils; 1mil: 50-200 mils (1µm: 0-1mm; 10µm: 1-5mm)
  • Minimum convex surface radius 4mm (0.16″)
  • Minimum concave surface radius 25mm (0.98″)
  • Minimum headroom 36mm (1.42″)
  • Minimum sample diameter: 8mm (0.32″)