Adjustable focus thermal imager

Testo 882
For thermography, locate structural defects in buildings, and prevent heat loss

$8,181.00 CAD

  • 12 months limited warranty
  • 320 x 240 array for a clear, accurate image
  • Large field of view with 32° lens
  • High image quality: NETD < 60mk
  • Voice recording with the practical headset
  • Free shipping across Canada
CLICK HERE TO ADD A CALIBRATION CERTIFICATE

Support, maintenance, calibration
1 800 463-4363

The Testo 882 Thermal Imager stands out because of the new detector with a 320 x 240 array. It is a feature-rich thermal imager that can be used in a variety of thermography applications.

With easy one-handed operation, 32° adjustable focus lens, and Lens Protector, the Testo 882 thermal imager is a versatile solution for a wide variety of thermal imaging applications.

An innovative thermal Imager for a great price

  1. 320 x 240 array for a clear, accurate image
  2. Large field of view with 32° lens
  3. High image quality: NETD < 60mk
  4. Voice recording with the practical headset
  5. A built-in digital camera with power LEDs
  6. Min/Max on area calculation
  7. Lens protection glass
  8. High-temperature measurement up to 1022°F
  9. Manual and Dynamic motor focus for sharp images and true one-hand operation
  10. Isotherm display in the instrument
  11. Auto hot/cold spot recognition

TRUST YOUR TEMPERATURE MEASUREMENT RESULTS

Testo thermal imagers adapt to the requirements for applications with high temperatures. With the high-temperature option, the measuring range can be flexibly extended up to 1,200 °C. The high-contrast presentation on the display is achieved via the high-temperature iron HT color palette or the special histogram adjustment.

PREVENT MECHANICAL FAILURE

To maintain the safety and reliability of machines, thermal imaging is used to identify problem components showing elevated stress levels caused by friction, misalignment, or internal damage. The high-temperature resolution thermal images will identify problem areas. For example, failing bearings will show clearly their location in the thermal image. Preventive maintenance can be scheduled then between the shifts to eliminate production downtime.

PREVENT ELECTRICAL DEVICE FAILURE

Testo thermal cameras are used to spot overheating components in the low, medium, and high voltage systems. Thermal images help to locate parts that are either failing or exposed to imbalanced loads. Routine thermal scans are used to prevent outages and fire risks.

LOCATE STRUCTURAL DEFECTS IN BUILDINGS. AND PREVENT HEAT LOSS

These cameras are used for speedy detection of structural problems in the new and old buildings. Roof leaks are often located away from the dripping water, and hard to trace windows permeability, or the mold hazard areas come clear in thermal images. Testo thermal cameras are ideal to investigate heat losses in your home, thermal bridges, and missing insulation.

With 76,800 measurement points, you can see small temperature details of the targeted area. It makes it much easier for you to detect anomalies and weaknesses from greater distances. The built-in digital camera with power LEDs simultaneously store a parallel visual image of the targeted area. The power LEDs guarantee you optimum illumination of dark areas when recording real images. Testo IRSoft software package includes our TwinPix feature which allows you to overlay the thermal and visual image to better understand the targeted conditions. Easy operation with simple icons and intuitive menus. This thermal imager can also be equipped to measure high temperatures up to 1022°F

Specifications
Detector type FPA 320 x 240 pixels, a.Si
Thermal sensitivity (NETD) <60 mK at 30°C (86°F)
Field of view/min. focus distance 32° x 23° / 7.8’’ (standard lens)
Geometric resolution (IFOV) 1.7 mrad
Image refresh rate 9 Hz
Focus manual and motor focus
Spectral range 8 to 14 μm
Optical field/min. focus distance 33° x 25° / 15.7’’
Image size 640 x 480 pixels
Image display 3.5’’ LCD with 320 x 240 pixels
Display options only IR / only digital image / IR and digital image
Video output USB 2.0
Color palettes 9 options (iron bow, rainbow, blue-red, greyscale, inverted grey, sepia, Testo, iron)
Temperature range -4°F to 232°F (-20°C to +100°C) +32°F to +662°F (0°C to 350°C),switchable
High-temperature option +662°F to +1022°F (350°C to +550°C)
Accuracy ± 2°C, ± 2% of rdg, (-4°F to +662°F) ± 3°C, ± 3% of rdg, (+662°F to +1022°F)
Minimum diameter measurement point 0.2’’ at 3 ft.
Setting emissivity 0.01 to 1 manual
File format .bmt; export options in .bmp, .jpg, .png, .csv, .xls
Data storage device 2 GB SD card (approx. 1000 images)
Battery type Li-ion battery
Operating time 4 hours
Operating temperature range 5°F to +104°F
Storage temperature range -22°F to +140°F
Protection class of housing -22°F to +140°F
Protection class of housing IP 54
Weight approx. 2 lbs
Dimensions 6” x 4.2” x 10.3”
Tripod mounting Yes with adapter
Housing ABS
PC Software
System requirements Windows XP (Service Pack 2) Windows Vista, Windows 7, USB 2.0 interface
Warranty 2 years
Accessories
Emissivity adhesive tape Heatproof up to 572°F 0554 0051
Two-bay battery charger 0554 8801
Spare battery 0554 8802
Tripod 0554 8804
Protective lens 0554 8805
Ordering Information
882 Thermal Imager Kit Part no. 0560 0882 70
All Imager Kits will be delivered in a hardshell case including SD card, USB cable, software power supply, and tripod mounting plate.

QUICK TIPS:

HOW TO DETECT BUILDING HEAT LOSS USING TESTO 882?

1. Point the imager at the target and press the [Trigger]. – The image is frozen (fixed image).
If the image is to be saved, the desired storage location can be set using the left quick-select button, see Select the storage location
• Infrared image or infrared/real image is shown: Infrared image is saved, a real image is saved in the same file as an attachment to the infrared image (even when saving in infrared image mode)1.
• Real image is shown: Real image is saved.

2. Save image: Press [Trigger] again, or: Press [OK]. or Discard image: Press [ESC].

read more in the user manual 

The Testo 882 Thermal Imager stands out because of the new detector with a 320 x 240 array. It is a feature-rich thermal imager that can be used in a variety of thermography applications.

With easy one-handed operation, 32° adjustable focus lens, and Lens Protector, the Testo 882 thermal imager is a versatile solution for a wide variety of thermal imaging applications.

An innovative thermal Imager for a great price

  1. 320 x 240 array for a clear, accurate image
  2. Large field of view with 32° lens
  3. High image quality: NETD < 60mk
  4. Voice recording with the practical headset
  5. A built-in digital camera with power LEDs
  6. Min/Max on area calculation
  7. Lens protection glass
  8. High-temperature measurement up to 1022°F
  9. Manual and Dynamic motor focus for sharp images and true one-hand operation
  10. Isotherm display in the instrument
  11. Auto hot/cold spot recognition

TRUST YOUR TEMPERATURE MEASUREMENT RESULTS

Testo thermal imagers adapt to the requirements for applications with high temperatures. With the high-temperature option, the measuring range can be flexibly extended up to 1,200 °C. The high-contrast presentation on the display is achieved via the high-temperature iron HT color palette or the special histogram adjustment.

PREVENT MECHANICAL FAILURE

To maintain the safety and reliability of machines, thermal imaging is used to identify problem components showing elevated stress levels caused by friction, misalignment, or internal damage. The high-temperature resolution thermal images will identify problem areas. For example, failing bearings will show clearly their location in the thermal image. Preventive maintenance can be scheduled then between the shifts to eliminate production downtime.

PREVENT ELECTRICAL DEVICE FAILURE

Testo thermal cameras are used to spot overheating components in the low, medium, and high voltage systems. Thermal images help to locate parts that are either failing or exposed to imbalanced loads. Routine thermal scans are used to prevent outages and fire risks.

LOCATE STRUCTURAL DEFECTS IN BUILDINGS. AND PREVENT HEAT LOSS

These cameras are used for speedy detection of structural problems in the new and old buildings. Roof leaks are often located away from the dripping water, and hard to trace windows permeability, or the mold hazard areas come clear in thermal images. Testo thermal cameras are ideal to investigate heat losses in your home, thermal bridges, and missing insulation.

With 76,800 measurement points, you can see small temperature details of the targeted area. It makes it much easier for you to detect anomalies and weaknesses from greater distances. The built-in digital camera with power LEDs simultaneously store a parallel visual image of the targeted area. The power LEDs guarantee you optimum illumination of dark areas when recording real images. Testo IRSoft software package includes our TwinPix feature which allows you to overlay the thermal and visual image to better understand the targeted conditions. Easy operation with simple icons and intuitive menus. This thermal imager can also be equipped to measure high temperatures up to 1022°F

Specifications
Detector type FPA 320 x 240 pixels, a.Si
Thermal sensitivity (NETD) <60 mK at 30°C (86°F)
Field of view/min. focus distance 32° x 23° / 7.8’’ (standard lens)
Geometric resolution (IFOV) 1.7 mrad
Image refresh rate 9 Hz
Focus manual and motor focus
Spectral range 8 to 14 μm
Optical field/min. focus distance 33° x 25° / 15.7’’
Image size 640 x 480 pixels
Image display 3.5’’ LCD with 320 x 240 pixels
Display options only IR / only digital image / IR and digital image
Video output USB 2.0
Color palettes 9 options (iron bow, rainbow, blue-red, greyscale, inverted grey, sepia, Testo, iron)
Temperature range -4°F to 232°F (-20°C to +100°C) +32°F to +662°F (0°C to 350°C),switchable
High-temperature option +662°F to +1022°F (350°C to +550°C)
Accuracy ± 2°C, ± 2% of rdg, (-4°F to +662°F) ± 3°C, ± 3% of rdg, (+662°F to +1022°F)
Minimum diameter measurement point 0.2’’ at 3 ft.
Setting emissivity 0.01 to 1 manual
File format .bmt; export options in .bmp, .jpg, .png, .csv, .xls
Data storage device 2 GB SD card (approx. 1000 images)
Battery type Li-ion battery
Operating time 4 hours
Operating temperature range 5°F to +104°F
Storage temperature range -22°F to +140°F
Protection class of housing -22°F to +140°F
Protection class of housing IP 54
Weight approx. 2 lbs
Dimensions 6” x 4.2” x 10.3”
Tripod mounting Yes with adapter
Housing ABS
PC Software
System requirements Windows XP (Service Pack 2) Windows Vista, Windows 7, USB 2.0 interface
Warranty 2 years
Accessories
Emissivity adhesive tape Heatproof up to 572°F 0554 0051
Two-bay battery charger 0554 8801
Spare battery 0554 8802
Tripod 0554 8804
Protective lens 0554 8805
Ordering Information
882 Thermal Imager Kit Part no. 0560 0882 70
All Imager Kits will be delivered in a hardshell case including SD card, USB cable, software power supply, and tripod mounting plate.

QUICK TIPS:

HOW TO DETECT BUILDING HEAT LOSS USING TESTO 882?

1. Point the imager at the target and press the [Trigger]. – The image is frozen (fixed image).
If the image is to be saved, the desired storage location can be set using the left quick-select button, see Select the storage location
• Infrared image or infrared/real image is shown: Infrared image is saved, a real image is saved in the same file as an attachment to the infrared image (even when saving in infrared image mode)1.
• Real image is shown: Real image is saved.

2. Save image: Press [Trigger] again, or: Press [OK]. or Discard image: Press [ESC].

read more in the user manual