{"id":25914,"date":"2022-10-24T21:21:39","date_gmt":"2022-10-24T21:21:39","guid":{"rendered":"https:\/\/geneqonline.com\/?post_type=product&#038;p=25914"},"modified":"2023-11-28T19:17:46","modified_gmt":"2023-11-28T19:17:46","slug":"ph-meter-for-swimming-pool-or-spa","status":"publish","type":"product","link":"https:\/\/geneqonline.com\/fr\/product\/ph-meter-for-swimming-pool-or-spa\/","title":{"rendered":"PH-m\u00e8tre pour piscine ou spa"},"content":{"rendered":"<h2>Ce pH-m\u00e8tre Hanna est con\u00e7u pour mesurer le pH et le potentiel Redox de l&#8217;eau d&#8217;une piscine, d&#8217;un spa ou d&#8217;une cuve thermale. Ce testeur l\u00e9ger et \u00e9tanche offre des mesures de pH, ORP et temp\u00e9rature de haute pr\u00e9cision dans une seule unit\u00e9 portable. Plus besoin de passer d&#8217;un appareil \u00e0 l&#8217;autre pour vos mesures de routine.<\/h2>\n<p>Le testeur combin\u00e9 HI981214 Pool Line est un pH-m\u00e8tre \u00e9tanche tr\u00e8s pr\u00e9cis qui peut \u00e9galement mesurer le potentiel Redox et la temp\u00e9rature. Ce testeur combin\u00e9 flottant et \u00e9tanche poss\u00e8de un \u00e9cran LCD facile \u00e0 lire et un arr\u00eat automatique. Toutes les lectures de pH sont automatiquement compens\u00e9es en temp\u00e9rature (ATC) pour les variations de temp\u00e9rature.<\/p>\n<p>HI981214 est id\u00e9al pour v\u00e9rifier le pH et les niveaux de d\u00e9sinfection des piscines, des jacuzzis et des spas. Une lecture pr\u00e9cise du pH est essentielle pour s&#8217;assurer que le chlore est principalement sous la forme d&#8217;acide hypochloreux plut\u00f4t que sous la forme d&#8217;hypochlorite, qui est moins efficace pour tuer les bact\u00e9ries. Le pH id\u00e9al pour une piscine se situe entre 7,2 et 7,4.<\/p>\n<p>La partie ORP de l&#8217;appareil est utilis\u00e9e pour surveiller le niveau de d\u00e9sinfection de la piscine afin de s&#8217;assurer qu&#8217;il y a suffisamment de chlore pour prot\u00e9ger les baigneurs des bact\u00e9ries. La lecture ORP id\u00e9ale est de +650 mV. \u00c0 ce voltage, toute bact\u00e9rie sera inactiv\u00e9e en peu de temps. Il est important de noter que si un stabilisateur tel que l&#8217;acide cyanurique est utilis\u00e9, le stabilisateur, en tant qu&#8217;agent r\u00e9ducteur, masque le potentiel d&#8217;oxydation du chlore. Le potentiel d&#8217;oxydation ne doit pas \u00eatre utilis\u00e9 lorsque le chlore est introduit sous forme de galette solide, car il est probable qu&#8217;elle contienne \u00e9galement des stabilisants.<\/p>\n<h3 dir=\"ltr\">Cartouche d&#8217;\u00e9lectrode ORP rempla\u00e7able<\/h3>\n<p dir=\"ltr\">Le testeur HI981214 dispose d&#8217;une cartouche d&#8217;\u00e9lectrode pH facile \u00e0 remplacer avec une jonction en tissu extensible. La jonction en tissu extensible permet d&#8217;augmenter la dur\u00e9e de vie de l&#8217;\u00e9lectrode et la cartouche pH rempla\u00e7able signifie que ce testeur n&#8217;a pas besoin d&#8217;\u00eatre jet\u00e9 lorsque le capteur pH est \u00e9puis\u00e9. De plus, le connecteur robuste et encliquetable signifie qu&#8217;il n&#8217;y a pas de broches \u00e0 plier ou \u00e0 casser !<\/p>\n<h3 dir=\"ltr\">Electrode ORP en platine<\/h3>\n<p dir=\"ltr\">La sonde ORP utilise un capteur \u00e0 pointe de platine, qui est id\u00e9al pour les r\u00e9actions d&#8217;oxydation telles que l&#8217;ajout de chlore pour la d\u00e9sinfection.<\/p>\n<h3 dir=\"ltr\">Caract\u00e9ristiques en un coup d&#8217;\u0153il :<\/h3>\n<p><strong>3 capteurs dans un seul compteur<\/strong><\/p>\n<ul>\n<li>3 capteurs en un seul compteur<\/li>\n<li>Electrode ORP<\/li>\n<li>Sonde de temp\u00e9rature pour les mesures de pH compens\u00e9es en temp\u00e9rature<\/li>\n<\/ul>\n<p><strong>\u00c9tanche<\/strong><\/p>\n<ul>\n<li>Con\u00e7u pour flotter en cas de chute accidentelle dans l&#8217;\u00e9chantillon.<\/li>\n<\/ul>\n<p><strong>Large gamme<\/strong><\/p>\n<ul>\n<li>Plage de pH allant de -2,00 \u00e0 16,00 pH<br \/>\nGamme ORP de \u00b11000 mV<\/li>\n<\/ul>\n<p><strong>Compensation automatique de la temp\u00e9rature<\/strong><\/p>\n<ul>\n<li>Toutes les mesures de pH sont compens\u00e9es pour les variations de temp\u00e9rature.<\/li>\n<li>La temp\u00e9rature est affich\u00e9e en oC ou oF en m\u00eame temps que la lecture du pH ou du potentiel Redox.<\/li>\n<\/ul>\n<p><strong>Indicateur de stabilit\u00e9<\/strong><\/p>\n<ul>\n<li>Le compteur affiche une horloge qui dispara\u00eet lorsque la lecture est stable.<\/li>\n<\/ul>\n<p><strong>HOLD button<\/strong><\/p>\n<ul>\n<li>G\u00e8le la lecture sur l&#8217;\u00e9cran pour permettre l&#8217;enregistrement de la mesure<\/li>\n<\/ul>\n<p><strong>BEPS (Syst\u00e8me de pr\u00e9vention des erreurs de batterie<\/strong><\/p>\n<ul>\n<li>Le compteur s&#8217;arr\u00eate automatiquement s&#8217;il n&#8217;y a pas assez de courant pour obtenir une mesure pr\u00e9cise.<\/li>\n<\/ul>\n<p><strong>Niveau de la batterie en % au d\u00e9marrage<\/strong><\/p>\n<p><strong>Indicateur de batterie faible<\/strong><\/p>\n<ul>\n<li>Lorsque le niveau est inf\u00e9rieur \u00e0 5 %, le symbole de la batterie sur l&#8217;\u00e9cran LCD clignote pour indiquer que la batterie est faible.<\/li>\n<\/ul>\n<p><strong>Arr\u00eat Automatique<\/strong><\/p>\n<ul>\n<li>La fonction d&#8217;arr\u00eat automatique \u00e9teint automatiquement le compteur apr\u00e8s 8 minutes de non-utilisation afin de maximiser la dur\u00e9e de vie des piles.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">SKU<\/th>\n<td data-th=\"SKU\">HI981214<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Product Name<\/th>\n<td data-th=\"Product Name\">Pool Line Combo pH\/ ORP Tester &#8211; HI981214<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Plage pH<\/th>\n<td data-th=\"pH Range\">-2.00 to 16.00 pH<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">R\u00e9solution pH<\/th>\n<td data-th=\"pH Resolution\">0.01 pH<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Pr\u00e9cision pH<\/th>\n<td data-th=\"pH Accuracy\">\u00b10.05 pH<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u00c9talonnage du pH<\/th>\n<td data-th=\"pH Calibration\">automatique, \u00e0 un ou deux points avec deux jeux de tampons standards (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Compensation de la temp\u00e9rature du pH<\/th>\n<td data-th=\"pH Temperature Compensation\">automatique<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Gamme ORP<\/th>\n<td data-th=\"ORP Range\">\u00b11000 mV<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">R\u00e9solution ORP<\/th>\n<td data-th=\"ORP Resolution\">1 mV<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Pr\u00e9cision de l&#8217;ORP<\/th>\n<td data-th=\"ORP Accuracy\">\u00b12 mV<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Plage de temp\u00e9rature<\/th>\n<td data-th=\"Temperature Range\">-5.0 to 60.0 \u00b0C (23.0 to 140.0 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Pr\u00e9cision de la temp\u00e9rature<\/th>\n<td data-th=\"Temperature Accuracy\">\u00b10.5 \u00b0C (\u00b11.0 \u00b0F)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Electrode de pH<\/th>\n<td data-th=\"pH Electrode\">HI73127<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Arr\u00eat automatique<\/th>\n<td data-th=\"Automatic Shut-Off\">Apr\u00e8s 8 minutes de non-utilisation<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Type de batterie \/ Dur\u00e9e de vie<\/th>\n<td data-th=\"Battery Type\/Life\">1.5V (4)\/ Environ 250 heures<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Environnement<\/th>\n<td data-th=\"Environment\">-5 to 50 \u00b0C (23 to 122 \u00b0F); RH 100%<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Dimensions<\/th>\n<td data-th=\"Dimensions\">171 x 41 x 26 mm (6.7 x 1.6 x 1.0\u201d)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Poids<\/th>\n<td data-th=\"Weight\">83 g (2.9 oz.)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"color: #3366ff; font-size: 25px;\"><span style=\"color: #ff6600;\">CONSEIL RAPIDE:<\/span><\/span><\/p>\n<h3>Mesure du pH<\/h3>\n<p>Appuyez sur SET\/HOLD pour s\u00e9lectionner le mode pH. Placer l&#8217;\u00e9lectrode dans la solution \u00e0 tester tout en remuant doucement. La mesure doit \u00eatre effectu\u00e9e apr\u00e8s la disparition de l&#8217;\u00e9tiquette de stabilit\u00e9. La valeur du pH est affich\u00e9e sur la premi\u00e8re ligne de l&#8217;\u00e9cran LCD et la temp\u00e9rature sur la deuxi\u00e8me ligne de l&#8217;\u00e9cran LCD. Remarque : Avant d&#8217;effectuer une mesure de pH, assurez-vous que le testeur a \u00e9t\u00e9 calibr\u00e9 (l&#8217;\u00e9tiquette &#8220;CAL&#8221; est affich\u00e9e).<\/p>\n<h3>Mesure de l&#8217;ORP<\/h3>\n<p>Utiliser SET\/HOLD pour s\u00e9lectionner le mode ORP. Placez l&#8217;\u00e9lectrode dans la solution \u00e0 tester. La mesure doit \u00eatre effectu\u00e9e apr\u00e8s la disparition de l&#8217;\u00e9tiquette de stabilit\u00e9. La valeur ORP (mV) est affich\u00e9e sur la premi\u00e8re ligne de l&#8217;\u00e9cran LCD et la temp\u00e9rature sur la deuxi\u00e8me ligne de l&#8217;\u00e9cran LCD.<\/p>\n<p><a href=\"https:\/\/geneqonline.com\/cart\/?add-to-cart=25914\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-21568 size-full\" src=\"https:\/\/geneqonline.com\/wp-content\/uploads\/2020\/06\/1-Free-shipping-fr-img.jpg\" alt=\"livraison gratiut canada\" width=\"532\" height=\"144\" srcset=\"https:\/\/geneqonline.com\/wp-content\/uploads\/2020\/06\/1-Free-shipping-fr-img.jpg 532w, https:\/\/geneqonline.com\/wp-content\/uploads\/2020\/06\/1-Free-shipping-fr-img-300x81.jpg 300w\" sizes=\"auto, (max-width: 532px) 100vw, 532px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<h3><span style=\"color: #333399;\">Vous voulez plus de fonctionnalit\u00e9s ? HI97711C<\/span><\/h3>\n<p><a href=\"https:\/\/geneqonline.com\/fr\/produit\/photometre-chlore-libre-et-total\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-28127\" src=\"https:\/\/geneqonline.com\/wp-content\/uploads\/2022\/10\/Hanna-portable-photometer-fr.jpg\" alt=\"Hanna-portable-photom\u00e8tre\" width=\"920\" height=\"454\" srcset=\"https:\/\/geneqonline.com\/wp-content\/uploads\/2022\/10\/Hanna-portable-photometer-fr.jpg 920w, https:\/\/geneqonline.com\/wp-content\/uploads\/2022\/10\/Hanna-portable-photometer-fr-300x148.jpg 300w, https:\/\/geneqonline.com\/wp-content\/uploads\/2022\/10\/Hanna-portable-photometer-fr-768x379.jpg 768w, https:\/\/geneqonline.com\/wp-content\/uploads\/2022\/10\/Hanna-portable-photometer-fr-767x378.jpg 767w\" sizes=\"auto, (max-width: 920px) 100vw, 920px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li>Etanche \u00e0 l&#8217;eau<\/li>\n<li>Electrode pH rempla\u00e7able<\/li>\n<li>Etalonnage automatique<\/li>\n<\/ul>\n<table style=\"height: 28px;\" border=\"0\" width=\"424\">\n<tbody>\n<tr>\n<td width=\"100\"><a href=\"https:\/\/geneqonline.com\/product\/calibration-ph-meters\/\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-18658\" src=\"https:\/\/geneqonline.com\/wp-content\/uploads\/2020\/07\/cert-small.jpg\" alt=\"\" width=\"200\" height=\"78\" \/><\/a><\/td>\n<td><a href=\"https:\/\/geneqonline.com\/product\/calibration-ph-meters\/\">CLIQUEZ ICI POUR AJOUTER UN CERTIFICAT D&#8217;\u00c9TALONNAGE $100.00 CAD<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"color: #808080;\">Support, maintenance, calibration &#8211;<br \/>\n<\/span><span style=\"color: #808080; font-size: 18pt;\">1 800 463-4363<\/span><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":26509,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[1143,631,238,625,144],"product_tag":[],"class_list":{"0":"post-25914","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-analyseur-deau-piscine","7":"product_cat-essais-des-materiaux-et-securite-du-travail","8":"product_cat-hanna","9":"product_cat-materiel-de-laboratoire","10":"product_cat-ph-metres","12":"first","13":"instock","14":"taxable","15":"shipping-taxable","16":"purchasable","17":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/geneqonline.com\/fr\/wp-json\/wp\/v2\/product\/25914","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/geneqonline.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/geneqonline.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/geneqonline.com\/fr\/wp-json\/wp\/v2\/comments?post=25914"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/geneqonline.com\/fr\/wp-json\/wp\/v2\/media\/26509"}],"wp:attachment":[{"href":"https:\/\/geneqonline.com\/fr\/wp-json\/wp\/v2\/media?parent=25914"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/geneqonline.com\/fr\/wp-json\/wp\/v2\/product_brand?post=25914"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/geneqonline.com\/fr\/wp-json\/wp\/v2\/product_cat?post=25914"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/geneqonline.com\/fr\/wp-json\/wp\/v2\/product_tag?post=25914"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}