{"id":24476,"date":"2022-04-28T22:53:23","date_gmt":"2022-04-28T22:57:00","guid":{"rendered":"https:\/\/geneqonline.com\/?post_type=product&#038;p=24476"},"modified":"2023-07-24T16:00:08","modified_gmt":"2023-07-24T16:00:08","slug":"jauge-epaisseur-ultrasonique","status":"publish","type":"product","link":"https:\/\/geneqonline.com\/fr\/product\/jauge-epaisseur-ultrasonique\/","title":{"rendered":"Jauge d\u2019\u00e9paisseur ultrasonique"},"content":{"rendered":"<h2>Le Jauge d&#8217;\u00e9paisseur ultrasonique et de pr\u00e9cision par ultrasons de la gamme Elcometer NDT MTG et PTG sont id\u00e9ales pour mesurer et enregistrer les \u00e9paisseurs de mat\u00e9riaux comprises entre 0.2 mm (0.008&#8243;) et 500 mm (20&#8243;).<\/h2>\n<ul>\n<li>Structure de menu multilingue simple d&#8217;emploi<\/li>\n<li>Robuste, r\u00e9sistant aux chocs, \u00e0 l&#8217;eau et \u00e0 la poussi\u00e8re \u00e9quivalent IP54<\/li>\n<li>Ecran couleur lumineux avec r\u00e9tro\u00e9clairage permanent<\/li>\n<li>Capteur de lumi\u00e8re ambiante avec luminosit\u00e9 r\u00e9glable<\/li>\n<li>Ecran TFT 6 cm (2,4&#8243;) r\u00e9sistant aux solvants et \u00e0 la rayure<\/li>\n<li>Touches d&#8217;analyse larges<\/li>\n<li>Alimentation par prise USB via PC<\/li>\n<li>Actualisation du logiciel de la jauge via ElcoMaster \u00ae<\/li>\n<li>Garantie de la jauge: 2 ans<\/li>\n<\/ul>\n<table>\n<tbody>\n<tr>\n<td><strong>Simple<\/strong><\/td>\n<td>Les jauges de mesure d&#8217;\u00e9paisseur par ultrasons de la gamme MTG &amp; PTG ont \u00e9t\u00e9 sp\u00e9cialement con\u00e7ues pour leur facilit\u00e9 d&#8217;utilisation, de calibration et de cr\u00e9ation de rapports d&#8217;inspection<\/td>\n<\/tr>\n<tr>\n<td><strong>Pr\u00e9cises<\/strong><\/td>\n<td>Les gammes de produits MTG et PTG ont une pr\u00e9cision de mesure de \u00b11% sur l&#8217;ensemble de leur plage de mesure. Des mesures pr\u00e9cises et r\u00e9p\u00e9tables peuvent \u00eatre prises sur des surfaces lisses, rugueuses, courbes, et avec ou sans rev\u00eatement. Le t\u00e9moin de stabilit\u00e9 donne une indication visuelle de la puissance et fiabilit\u00e9 du signal ultrasonique.<\/td>\n<\/tr>\n<tr>\n<td><strong>Performantes<\/strong><\/td>\n<td>Les mod\u00e8les MTG2 et MTG4 ont un taux de r\u00e9p\u00e9tition mesure fixe de 4 Hz (4 mesures par seconde); en revanche, les jauges MTG6, PTG6, MTG8 &amp; PTG8 ont des taux de r\u00e9p\u00e9tition variables de 4, 8 et 16 Hz (4, 8 ou 16 mesures par seconde) au choix de l&#8217;utilisateur.<\/td>\n<\/tr>\n<tr>\n<td><strong>Puissantes<\/strong><\/td>\n<td>Les jauges MTG6, MTG8 &amp; PTG8 ont une fonction acquisition de donn\u00e9es. Le mod\u00e8le MTG6 permet de m\u00e9moriser 1 500 mesures dans un lot unique ; les mod\u00e8les MTG8 &amp; PTG8 peuvent enregistrer 100 000 mesures dans un maximum de 1 000 lots s\u00e9quentiels ou de type &#8216;Grille&#8217; avec intitul\u00e9 alpha-num\u00e9rique. Ils sont compatibles avec les logiciels ElcoMaster\u00ae et ElcoMaster\u00ae Mobile App ; les donn\u00e9es peuvent \u00eatre transf\u00e9r\u00e9es par liaison USB ou Bluetooth\u00ae directement sur PC ou appareils mobiles \u00e9quip\u00e9s d&#8217;iOS* ou Android\u2122 pour la cr\u00e9ation instantan\u00e9e de rapports d&#8217;inspection.<\/td>\n<\/tr>\n<tr>\n<td><strong>Solides<\/strong><\/td>\n<td>Gr\u00e2ce \u00e0 leur \u00e9cran r\u00e9sistant aux solvants et \u00e0 la rayure, et \u00e0 leur boitier \u00e9tanche, robuste et r\u00e9sistant aux chocs (\u00e9tanch\u00e9it\u00e9 \u00e0 l&#8217;eau et \u00e0 la poussi\u00e8re \u00e9quivalent IP54),les jauges des gammes MTG &amp; PTG sont adapt\u00e9es aux environnements les plus s\u00e9v\u00e8res.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/geneq.com\/image\/catalog\/old\/products-3\/elcometerIMG01.jpg\" alt=\"\" width=\"158\" height=\"148\" \/>\u00a0\u00a0 \u00a0<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/geneq.com\/image\/catalog\/old\/products-3\/elcometerIMG02.jpg\" alt=\"\" width=\"161\" height=\"148\" \/>\u00a0 \u00a0\u00a0<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/geneq.com\/image\/catalog\/old\/products-3\/elcometerIMG03.jpg\" alt=\"\" width=\"168\" height=\"148\" \/><\/p>\n<h3><\/h3>\n<h3>Explication des modes de mesure<\/h3>\n<p>Les jauges MTG &amp; PTG de la gamme Elcometer NDT poss\u00e8dent plusieurs modes de mesure destin\u00e9s \u00e0 aider<br \/>\nl&#8217;utilisateur \u00e0 r\u00e9aliser une mesure d&#8217;\u00e9paisseur la \u00a0plus pr\u00e9cise possible. Les modes disponibles varient d&#8217;un mod\u00e8le \u00e0 l&#8217;autre ; de mani\u00e8re g\u00e9n\u00e9rale, leur nombre augmente avecle niveau de gamme de la jauge.<\/p>\n<table>\n<tbody>\n<tr>\n<td>Mode \u00c9cho &#8211; Puls\u00e9 (P-E)<\/td>\n<td>Id\u00e9al pour la d\u00e9tection de crat\u00e8res et de d\u00e9fauts, ce mode mesure l&#8217;\u00e9paisseur totale de la base de la sonde \u00e0 la limite de densit\u00e9 du mat\u00e9riau (g\u00e9n\u00e9ralement la face oppos\u00e9e).<\/td>\n<\/tr>\n<tr>\n<td>Mode \u00c9cho &#8211; \u00c9cho (E-E)<\/td>\n<td>Id\u00e9al pour mesurer les mat\u00e9riaux les plus fins compris entre 0.15-10.15 mm (0.006 &#8211; 0.4&#8243;),le mode Echo-Echo mesure l&#8217;\u00e9paisseur de la surface du mat\u00e9riau jusqu&#8217;\u00e0 la limite de densit\u00e9 de celui-ci (g\u00e9n\u00e9ralement la face oppos\u00e9e).<\/td>\n<\/tr>\n<tr>\n<td><strong>Mode \u00c9cho &#8211; \u00c9cho ThruPaint\u2122 (E-E)<\/strong><\/td>\n<td>Egalement connu sous le terme ThruPaint\u2122, ce mode permet de mesurer l&#8217;\u00e9paisseur du mat\u00e9riau du dessus de la surface \u00e0 la limite de densit\u00e9 du mat\u00e9riau (g\u00e9n\u00e9ralement la face oppos\u00e9e) en faisant abstraction de l&#8217;\u00e9paisseur de rev\u00eatement. Pour utiliser le mode \u00c9cho-\u00c9cho ThruPaint\u2122, une sonde d&#8217;\u00e9paisseur \u00e0 amortissement \u00e9lev\u00e9 est n\u00e9cessaire.required.<\/td>\n<\/tr>\n<tr>\n<td>Interface \u00c9cho (I-E)<\/td>\n<td>Con\u00e7u pour des mesures de haute pr\u00e9cision, le mode Interface-\u00c9cho affiche l&#8217;\u00e9paisseur totale du dessus de la surface \u00e0 la limite de densit\u00e9 du mat\u00e9riau.<\/td>\n<\/tr>\n<tr>\n<td>Mode Plastique (PLAS)<\/td>\n<td>Ce mode est utilis\u00e9 pour mesurer des plastiques tr\u00e8s fins. Il n\u00e9cessite l&#8217;utilisation d&#8217;un accessoire sp\u00e9cial, une ligne \u00e0 retard en graphite.<\/td>\n<\/tr>\n<tr>\n<td>Mode V\u00e9locit\u00e9 (VM)<\/td>\n<td>Le mode V\u00e9locit\u00e9 mesure la vitesse de propagation du son dans les mat\u00e9riaux. Il est id\u00e9al pour d\u00e9terminer l&#8217;homog\u00e9n\u00e9it\u00e9 d&#8217;un mat\u00e9riau ou d&#8217;un alliage, ainsi que la v\u00e9locit\u00e9 appropri\u00e9e pour la calibration d&#8217;un mat\u00e9riau.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Lecture des \u00e9crans<\/h3>\n<p>Les jauges Elcometer NDT MTG &amp; PTG poss\u00e8dent plusieurs modes de mesure pour que l&#8217;utilisateur \u00a0puisse choisir celui le mieux adapt\u00e9 \u00e0 son application. Les modes disponibles varient d&#8217;un mod\u00e8le \u00e0 l&#8217;autre; de mani\u00e8re g\u00e9n\u00e9rale, leur nombre augmente avec \u00a0le niveau de gamme de la jauge.<\/p>\n<h3>Jauge d\u2019\u00e9paisseur ultrasonique<\/h3>\n<table>\n<tbody>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/geneq.com\/image\/catalog\/old\/products-3\/elcometerMTGimg04.jpg\" alt=\"\" width=\"208\" height=\"150\" \/><\/td>\n<td><strong>Affichage<\/strong><\/td>\n<td>Toutes les jauges sont \u00e9quip\u00e9es d&#8217;un \u00e9cran couleur LCD enti\u00e8rement personnalisable, r\u00e9sistant aux\u00a0solvants et \u00e0 lab rayure. Elles \u00a0incluent \u00a0les modes de mesure suivants: \u00c9cho- \u00a0Puls\u00e9 \u00a0(P-E),\u00a0\u00c9cho-\u00c9cho \u00a0ThruPaint\u2122 (E-E),Interface \u00c9cho (I-E),Plastique (PLAS) et V\u00e9locit\u00e9 (pour plus\u00a0d&#8217;informations sur les modes de mesure, voir page 3). Il existe plusieurs unit\u00e9s de mesure selon le\u00a0mode de mesure s\u00e9lectionn\u00e9. Le t\u00e9moin de stabilit\u00e9 indique clairement la puissance et la fiabilit\u00e9\u00a0du signal ultrasonore.<\/td>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/geneq.com\/image\/catalog\/old\/products-3\/elcometerMTGimg005.jpg\" alt=\"\" width=\"206\" height=\"150\" \/><\/td>\n<td><strong>Mode Scan<\/strong><\/td>\n<td>Une fois ce mode activ\u00e9, l&#8217;utilisateur peut balayer de larges surfaces; la jauge prend des mesures\u00a0\u00e0 un taux de 16 Hz (16 mesures par seconde). Pendant chaque phase de scan, la jauge affiche\u00a0l&#8217;\u00e9paisseur actuelle ainsi qu&#8217;une barre graphique analogique indiquant l&#8217;\u00e9paisseur par rapport \u00e0\u00a0une valeur nominale et des limites \u00e9ventuellement d\u00e9finies par l&#8217;utilisateur; si une mesure est\u00a0en-dehors de ces limites, un signal visuel et sonore retentit. Lorsque la sonde est retir\u00e9e de la\u00a0surface, les valeurs d&#8217;\u00e9paisseur moyenne, mini et maxi s&#8217;affichent, ce qui fait du mode scan un\u00a0outil id\u00e9al pour v\u00e9rifier l&#8217;uniformit\u00e9 globale d&#8217;un \u00e9chantillon.<\/p>\n<p>&nbsp;<\/td>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/geneq.com\/image\/catalog\/old\/products-3\/elcometerMTGimg006.jpg\" alt=\"\" width=\"203\" height=\"150\" \/><\/td>\n<td><strong>Graphe de s\u00e9quence<\/strong><\/td>\n<td>Un graphe de tendance des 20 derni\u00e8res mesures indique les variations d&#8217;\u00e9paisseur du mat\u00e9riau sur\u00a0la zone test\u00e9e. Le graphe est mis \u00e0 jour \u00e0 chaque nouvelle mesure; chaque valeur situ\u00e9e en dehors\u00a0des limites d\u00e9finies apparait en rouge pour permettre \u00e0 l&#8217;utilisateur d&#8217;identifier facilement les\u00a0zones o\u00f9 la corrosion peut \u00eatre pr\u00e9sente ou les zones de sur-\u00e9paisseur.<\/td>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/geneq.com\/image\/catalog\/old\/products-3\/elcometerMTGimg007.jpg\" alt=\"\" width=\"205\" height=\"150\" \/><\/td>\n<td><strong>Statistiques \u00e0 l&#8217;\u00e9cran<\/strong><\/td>\n<td>L&#8217;utilisateur peut choisir d&#8217;afficher un maximum de 8 param\u00e8tres statistiques au choix parmi le\u00a0nombre de mesures (n),la valeur maxi, mini et moyenne (Hi, Lo, x\u00af ),l&#8217;\u00e9cart type (\u03c3),les valeurs \u00a0de limite haute et basse, et la plage<\/td>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/geneq.com\/image\/catalog\/old\/products-3\/elcometerMTGimg008.jpg\" alt=\"\" width=\"206\" height=\"150\" \/><\/p>\n<p>&nbsp;<\/td>\n<td><strong>Mode V\u00e9locit\u00e9<\/strong><\/td>\n<td>Le mode V\u00e9locit\u00e9 mesure la vitesse de propagation du son dans des mat\u00e9riaux. Il est id\u00e9al pour\u00a0d\u00e9terminer l&#8217;homog\u00e9n\u00e9it\u00e9 d&#8217;un mat\u00e9riau ou d&#8217;un alliage, ainsi que la v\u00e9locit\u00e9 appropri\u00e9e pour lacalibration d&#8217;un mat\u00e9riau<\/td>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/geneq.com\/image\/catalog\/old\/products-3\/elcometerMTGimg010.jpg\" alt=\"\" width=\"203\" height=\"150\" \/><\/td>\n<td><strong>Lecture B-Scan<\/strong><\/td>\n<td>Le B-Scan bas\u00e9 sur le temps, transversal en deux dimensions fournit une vue graphique du mat\u00e9riau test\u00e9 id\u00e9ale pour les analyses en profondeur. \u00a0Le zoom du B-Scan peut \u00eatre r\u00e9gl\u00e9 en automatique ou d\u00e9fini par l&#8217;utilisateur pour une analyse d\u00e9taill\u00e9e d&#8217;une zone pr\u00e9cise.<\/td>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/geneq.com\/image\/catalog\/old\/products-3\/elcometerMTGimg011.jpg\" alt=\"\" width=\"203\" height=\"150\" \/><\/td>\n<td><strong>Mode Diff\u00e9rentiel<\/strong><\/td>\n<td>Une fois la valeur d&#8217;\u00e9paisseur nominale d\u00e9finie par l&#8217;utilisateur, la jauge affiche la valeur mesur\u00e9e ainsi que l&#8217;\u00e9cart par rapport \u00e0 la valeur nominale pour aider \u00e0 rep\u00e9rer les zones o\u00f9 l&#8217;\u00e9paisseur du mat\u00e9riau est inf\u00e9rieure ou sup\u00e9rieure aux sp\u00e9cifications<\/td>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/geneq.com\/image\/catalog\/old\/products-3\/elcometerMTGimg012.jpg\" alt=\"\" width=\"203\" height=\"150\" \/><\/td>\n<td><strong>Barre graphique<\/strong><\/td>\n<td>Elle repr\u00e9sente de mani\u00e8re analogique la valeur actuellement mesur\u00e9e ainsi que la valeur maxi (Hi),\u00a0mini (Lo) et la moyenne (x\u00af). Le graphe est automatiquement mis \u00e0 jour \u00e0 chaque nouvelle mesure.<\/td>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/geneq.com\/image\/catalog\/old\/products-3\/elcometerMTGimg013.jpg\" alt=\"\" width=\"203\" height=\"150\" \/><\/td>\n<td><strong>Mode Plastique<\/strong><\/td>\n<td>&nbsp;<\/p>\n<p>Ce mode est sp\u00e9cialement con\u00e7u pour la mesure de plastiques tr\u00e8s fins.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Jauge d\u2019\u00e9paisseur ultrasonique<\/h3>\n<table style=\"width: 754px;\">\n<tbody>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Model Number<\/td>\n<td style=\"width: 99px;\">MTG8<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Part Number (with transducer)<sup>1<\/sup><\/td>\n<td style=\"width: 99px;\">MTG8BDL-TXC<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Part Number (gauge only)<\/td>\n<td style=\"width: 99px;\">MTG8BDL<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Limits: 40 definable audible &amp; visual pass\/fail warnings<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Measurement Rate<\/td>\n<td style=\"width: 99px;\">4, 8, 16Hz<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 166px;\">Measurement Mode<\/td>\n<td style=\"width: 154px;\">Range<sup>3<\/sup><\/td>\n<td style=\"width: 303px;\" colspan=\"2\">Accuracy<sup>4<\/sup><\/td>\n<td style=\"width: 99px;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 166px;\">Pulsed Echo (P-E)<\/td>\n<td style=\"width: 154px;\">0.63-500mm (0.025-20\u201d)<\/td>\n<td style=\"width: 161px;\">\u00b10.05mm (0.63-9.99mm)<br \/>\n\u00b10.5% (10.00-500.00mm)<\/td>\n<td style=\"width: 142px;\">\u00b10.004\u201d (0.025-0.393\u201d)<br \/>\n\u00b10.5% (0.394-20.00\u201d)<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 166px;\">Echo Echo ThruPaint (E-E)<\/td>\n<td style=\"width: 154px;\">2.54-20.00mm<br \/>\n(0.100-0.787\u201d)<\/td>\n<td style=\"width: 161px;\">\u00b10.05mm (2.54-9.99mm)<br \/>\n\u00b10.5% (10.00-20.00mm)<\/td>\n<td style=\"width: 142px;\">\u00b10.004\u201d (0.100-0.393\u201d)<br \/>\n\u00b10.5% (0.394-0.787\u201d)<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 166px;\">Velocity Mode (VM)<\/td>\n<td style=\"width: 457px;\" colspan=\"3\">1,250-10,000m\/s (0.0492-0.3937in\/\u00b5s)<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\"><strong>Measurement Units<\/strong><\/td>\n<td style=\"width: 99px;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">mm or inches<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">m\/s, inch\/\u00b5s<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Repeatability \/ Stability Indicator<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\"><strong>Display Mode<\/strong><\/td>\n<td style=\"width: 99px;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Reading<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Selected statistics<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Scan thickness bar graph<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Run Chart<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Readings and Differential<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">B-Scan cross sectional display<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Selectable Reading Resolution<\/td>\n<td style=\"width: 99px;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Lo; 0.1mm, 0.01 Inch, 10m\/s, or 0.001 in\/\u03bcs<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Hi; 0.01mm, 0.001 Inch, 1m\/s, or 0.0001 in\/\u03bcs<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\"><strong>Statistics<\/strong><\/td>\n<td style=\"width: 99px;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Number of readings,n; Mean average, x<span class=\"font9\"><sup>\u00af\u00a0<\/sup>;<br \/>\nStandard deviation, \u03c3.<\/span><\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Lowest reading, Lo; Highest reading, Hi<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Low \/ high limit value<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Reading Range Value<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Nominal Value<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Number of readings below low limit<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Number of readings above high limit<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\"><strong>Calibration Options<\/strong><\/td>\n<td style=\"width: 99px;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Zero (using the integral zero disc)<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">1 &#8211; point<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">2 &#8211; point<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Material selection; 39 preset materials<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Factory; resets to the factory calibration<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Velocity (speed of sound)<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Known thickness value<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\"><strong>Calibration Features<\/strong><\/td>\n<td style=\"width: 99px;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Calibration lock; with optional PIN Lock<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Test calibration feature<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Calibration memories: 3 programmable memories<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Measurement outside calibration warning<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Data Logging<\/td>\n<td style=\"width: 99px;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Number of readings<\/td>\n<td style=\"width: 99px;\">100,000<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Number of batches<\/td>\n<td style=\"width: 99px;\">1,000<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Sequential batching<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Grid batching<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Fixed batch size mode; with batch linking<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Obstruct entry; add &#8216;obst&#8217; into grid location<\/td>\n<td style=\"width: 10px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Delete last reading<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Date &amp; time stamp<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Review, clear &amp; delete batches<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Alpha numeric batch names; user definable<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Batch review graph<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\"><strong>Data Output<\/strong><\/td>\n<td style=\"width: 99px;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">USB to PC<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Bluetooth<sup>\u00ae\u00a0<\/sup>to PC, Android<sup>\u2122\u00a0<\/sup>&amp; iOS devices<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">ElcoMaster<sup>\u00ae\u00a0<\/sup>software<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\"><strong>Transducer Probe Type<\/strong><\/td>\n<td style=\"width: 99px;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Dual Element<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Auto Transducer Recognition<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Auto V-path Correction<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Battery Type<sup>5<\/sup><\/td>\n<td style=\"width: 99px;\">2 x AA<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Battery Life<sup>5<\/sup>Alkaline: 15 hours\u00a0 Lithium: 28 hours<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Operating Temperature -10 to 50\u00b0 (14 to 122\u00b0F)<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Size (w x h x d) 145 x 73 x 37mm (5.7 x 2.84 x 1.46&#8243;)<\/td>\n<td style=\"width: 99px;\" align=\"center\">\u25a0<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 623px;\" colspan=\"4\">Gauge Weight (including batteries)<\/td>\n<td style=\"width: 99px;\">210g (7.4oz)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/geneqonline.com\/cart\/?add-to-cart=24476\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-21568 aligncenter\" src=\"https:\/\/geneqonline.com\/wp-content\/uploads\/2020\/11\/1-Free-shipping-fr-img.jpg\" alt=\"livraison gratuit Canada\" width=\"532\" height=\"144\" \/><\/a><\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/testcoatings.ca\/\"><span style=\"color: #3366ff; font-size: 25px;\"><span style=\"color: #ff6600;\">VISITEZ TESTCOATINGS.CA POUR PLUS DE PRODUITS ELCOMETER<\/span><\/span><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li>\u00a012 mois de garantie limit\u00e9e<\/li>\n<li>Peut stocker 100 000 lectures dans un maximum de 1 000 lots s\u00e9quentiels ou de type grille.<\/li>\n<li>Offre le B-Scan, une vue graphique bidimensionnelle en coupe transversale, bas\u00e9e sur le temps, du mat\u00e9riau test\u00e9.<\/li>\n<li>Robuste, r\u00e9sistant aux chocs, \u00e0 l&#8217;eau et \u00e0 la poussi\u00e8re, \u00e9quivalent \u00e0 IP54.<\/li>\n<\/ul>\n<p><span style=\"color: #333333;\">Support, maintenance, calibration <\/span><\/p>\n<p><span style=\"font-size: 18pt; color: #333333;\">1 800 463-4363<\/span><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":24478,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[474,631],"product_tag":[],"class_list":{"0":"post-24476","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-elcometer-fr","7":"product_cat-essais-des-materiaux-et-securite-du-travail","9":"first","10":"instock","11":"taxable","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/geneqonline.com\/fr\/wp-json\/wp\/v2\/product\/24476","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/geneqonline.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/geneqonline.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/geneqonline.com\/fr\/wp-json\/wp\/v2\/comments?post=24476"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/geneqonline.com\/fr\/wp-json\/wp\/v2\/media\/24478"}],"wp:attachment":[{"href":"https:\/\/geneqonline.com\/fr\/wp-json\/wp\/v2\/media?parent=24476"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/geneqonline.com\/fr\/wp-json\/wp\/v2\/product_brand?post=24476"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/geneqonline.com\/fr\/wp-json\/wp\/v2\/product_cat?post=24476"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/geneqonline.com\/fr\/wp-json\/wp\/v2\/product_tag?post=24476"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}